Краткое содержание страницы № 1
PAC260GB 24-04-2003 16:33 Pagina 1
Use and maintenance manual . . . . . . . . . . .page 2
Mode d’emploi et d’entretien . . . . . . . . . . .page 16
Instrucciones de uso . . . . . . . . . . . . . . . .página 29
Istruzioni per l’uso . . . . . . . . . . . . . . . . . .pagina 43
Краткое содержание страницы № 2
PAC260GB 24-04-2003 16:33 Pagina 2 Important Safeguards When using electrical appliances, basic safety precautions should always be followed, including the following: - Read all instructions. - To protect against fire, electrical shock and personal injury, do not immerse cord, plug or appliance in water or other liquid. - Close supervision is necessary when any appliance is used by or near children. -Do not operate with a damaged cord or plug, or after the appliance mal- functions, or has bee
Краткое содержание страницы № 3
PAC260GB 24-04-2003 16:33 Pagina 3 Dear user, We thank you for purchasing the Pinguino air conditioner and congratu- late you on your wise choice. For optimal results please read this manual carefully before installing or operating. We know that the Pinguino will maintain pleasingly comfortable environment at all times. With best wishes, De Longhi S.p.A. If you have any questions about the operation or service of your Pinguino, please call our toll-free service number 1-800-322-3848. or visi
Краткое содержание страницы № 4
PAC260GB 24-04-2003 16:33 Pagina 4 Specifications Power supply voltage V see rating label Frequency Hz 60 Cooling capacity: (*) see rating label Fan speeds 2 Dehumidification quotient (*) see rating label 1 31 22 / (560) Dimensions: width in. (mm) 30 (735) height in. (mm) 9 16 15 / (390) depth in. (mm) Net weight lb. (kg) 97 (44) *Data according to pending standard testing procedures subject to review by the U.S. Dept. of Energy. A HE (High efficiency) system with low energy consumption has
Краткое содержание страницы № 5
PAC260GB 24-04-2003 16:33 Pagina 5 Illustrated main features list Air outlet grid Timer cover (to adjust the timer slide cover side- ways) Castor Castor stops Water collecting tray Air filter Air intake grid Exaust hose Power cord comp. Reset button Drainage tube 5
Краткое содержание страницы № 6
PAC260GB 24-04-2003 16:33 Pagina 6 Accessories DESCRIPTION SUPPLIED Exhaust hose 1 Stopper + flange 1 Caster stop 2 Window nozzle 1 Adjustable window and door bracket 1 Suction disc 2 ACCESSORY CHECK Check that all parts listed in table are included. 6
Краткое содержание страницы № 7
PAC260GB 24-04-2003 16:33 Pagina 7 Setting up PERMANENT INSTALLATION The Pinguino accessories include two sets of flanges and stoppers, to be mountedl in different locations (two different rooms). Once installed, these vents (flanges) are the only items needed for using Pinguino. Permanent installation outlet holes must be in an exterior wall and opening diameter should not 1 exceed 3” /2. fig. 1 INSIDE OUTSIDE INSIDE OUTSIDE A1 fig. 2 in a window pane fig. 3 A2 through the wooden base-sec- I
Краткое содержание страницы № 8
PAC260GB 24-04-2003 16:33 Pagina 8 Setting up TEMPORARY INSTALLATION Note: In both cases (permanent and temporary installations) make sure that the Pinguino is positioned on level ground. If necessary use the two caster stops for the front casters This installation makes it easy to use Pinguino in any room, provided there is a window or a door: it allows you to use the Pinguino immediately. window bracket fig. 7 If you have a sash door, use the additional set provided in order to extend the a
Краткое содержание страницы № 9
PAC260GB 24-04-2003 16:33 Pagina 9 Setting up and recommendations SET UP INSTRUCTION For permanent installation place the Pinguino near the outlet opening in wall or window (where it is meant to be used). The diagram below shows the correct way to installl the exhaust hose. 1) Water collects at this point 2) Bend this section 3) Bend this section fig. 10 NO YES YES ELECTRICAL CONNECTION Check that the power supply voltage is 115 V ~ 60 Hz. Important: if you need to use and extension cord, ple
Краткое содержание страницы № 10
PAC260GB 24-04-2003 16:33 Pagina 10 Control panel ON/OFF button ON/OFF pilot light “Alarm” pilot light Timer ON/OFF pilot light Timer ON/OFF Selecting fan Timer notches Thermostat button speed button SETTING THE TIMER 1) Release B timer button The programmer/timer, like all clocks, must be 2) Set the operating times by pushing out the set to the exact time. If for example it is 4.00 notches on the dial corresponding to the p.m., turn the dial in a clockwise direction (fol- period required (ea
Краткое содержание страницы № 11
PAC260GB 24-04-2003 16:33 Pagina 11 How to start up the conditioner Plug the appliance into the mains. Select the “programmed” or “non pro- grammed” mode (see previous page) Select the fan speed required pressing “Fan speed” key C. AIR CONDITIONING Key A ON/OFF (conditioning) must be released Turn the thermostat to Max. Cold. Press key A (ON/OFF). ON/OFF signal lamp (conditioning) will come on. The appliance comes on. If not, refer to pag. 14. To switch off the appliance, press key A (ON/OFF
Краткое содержание страницы № 12
PAC260GB 24-04-2003 16:33 Pagina 12 Cleaning and maintenance PRECAUTIONS fig. 14 fig. 15 During cleaning and normal maintenance operations Under no circumstances should appliance be remember to disconnect plug. washed with runing water. Damage could be caused to the electrical circuit. CLEANING OF EXTERNAL HOUSING Use only mild soap and water. Do not use chemical cleaners. fig. 16 Clean with a damp cloth and dry thoroughly with fig. 17 a clean dry cloth. CONTROLS AT THE BEGINNING OF THE SEAS
Краткое содержание страницы № 13
PAC260GB 24-04-2003 16:33 Pagina 13 Cleaning and maintenance AIR FILTER CLEANING Maintenance of air filter Removal and replacement of air filter A clogged air filter reduces the quantity of circu- Gently pull filter upwards. lating air and the efficiency of the appliance. Push down to replace. Clean filter every week using a vacuum cleaner. fig. 19 fig. 20 Remove dust with a Rinse with running vacuum cleaner water fig. 21 Cleaning procedure To remove dust deposited on filter, use a vacuum cl
Краткое содержание страницы № 14
PAC260GB 24-04-2003 16:33 Pagina 14 Troubleshooting SYMPTOMS CAUSE SOLUTION The Pinguino does not - power failure - plug is disconnected - insert plug function: - ON/OFF switch is off - switch on - Timer key is in STOP position - release the TIMER key The Pinguino does not function - function fault warning - exhaust hose blocked -Check for obstruction of air light is on (pag. 10 - outlet vent - exhaust hose twisted or bent - eliminate irregularities “Alarm” light) - ventilation holes on the r
Краткое содержание страницы № 15
PAC260GB 24-04-2003 16:33 Pagina 15 LIMITED WARRANTY We warrant each DE’LONGHI AIR-CONDITIONER to be free from defects in material and work- manship. Our obligation under this warranty is to provide one year parts and labor free from purchase date, with an additional four (4) years on any part of the sealed system consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing. This war- ranty shall apply only if the AIR-CONDITIONER is used in accordance with the