Краткое содержание страницы № 1
DAC7037M 2006-11-14 Y.P.Chen
USE AND CARE
MANUAL
MANUEL
D'UTILISATION
Model • Modèle
DAC7037M
CAUTION:
Read and Follow All Safety Rules
and Operating Instructions Before
First Use of This Product.
Room Air Conditioner
Table of contents . . . . . . . . . . . . . . . . . . . . . . . 1
PRÉCAUTION:
Veuillez lire attentivement
les consignes de sécurité et les
instructions d'utilisation avant
Climatiseur de pièce
l'utilisation initiale de
ce produit.
Table of contents . . . . . . . . . . . .
Краткое содержание страницы № 2
Table of Contents Page Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Energy-Saving Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Installation Notes & Hardware. . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 3
Introduction Thank you for choosing a Diplomat Room Air Conditioner to cool your home. This Use and Care Manual provides information necessary for the proper care and maintenance of your new Room Air Conditioner. If properly maintained, your air conditioner will give you many years of trouble free operation. To avoid installation difficulties, read these instructions completely before installing/operating your unit. NOTE: This unit is NOT designed for through-the-wall installation. For easy r
Краткое содержание страницы № 4
Electrical Specifications 1. All wiring must comply with local and national The power cord supplied with this air conditioner electrical codes and must be installed by a contains a current leakage detection device de- qualified electrician. If you have any questions signed to reduce the risk of fire.Please refer to the regarding the following instructions, contact a section “ Power Supply Cord”for details.In the qualified electrician. event the power supply cord is damaged,it cannot 2. Check av
Краткое содержание страницы № 5
Energy-Saving Tips Your Room Air Conditioner is designed to be 4. Start your air conditioner before outdoor air highly efficient in energy savings. Follow these becomes hot and uncomfortable. This avoids an recommendations for greater efficiency. initial period of discomfort while unit is cooling 1. Select thermostat setting that suits your off the room. comfort needs and leave thermostat at that 5. When outdoor temperatures are cool enough, chosen setting. use HIGH or LOW FAN only. This ci
Краткое содержание страницы № 6
CAUTION Your unit is designed to evaporate condensation under normal conditions. However, under Because the compressor is located on the extreme humidity conditions, excess condensation controls side of the unit (left side), this side will may cause basepan to overflow to the outside. be heavier and more awkward to manipulate. The Unit should be installed where condensation Inadequate support on control side of the unit run-off cannot drip on pedestrians or neighboring can result in personal
Краткое содержание страницы № 7
Slide down into tabs 1. Assembly of the Upper Channel, to 3a. Completing the Installation (cont’d) Cabinet. • Carefully place the air conditioner into the window with the “L” shaped mounting bracket • "L" Shaped Top Channel: Install the "L" (on top) positioned in front of the upper window shaped channel to the top of the cabinet as sash. The bottom of the cabinet should be shown in Fig.3 using four(4)3/8"(10mm)screws. positioned on the “recessed” portion of the window frame. Pull
Краткое содержание страницы № 8
Operating Instructions SELECTOR SWITCH The selector switch controls fan speed and/or cooling speed. To set desired cooling temperature, simply rotate the SELECTOR TEM P . knob to the appropriate setting. 5 FAN SPEEDS 4 LOW FAN " "will circulate air at minimum Thermostat 6 speed without cooling. • MED FAN will circulate air at medium 3 " " speed without cooling. 2 HIGHFAN will circulate air at maximum • 1 " " 7 OFF speed without cooling. ARRÊT COOLING MODES • " " LOW COOL provides coolin
Краткое содержание страницы № 9
Care and Maintenance End-of-Season Care 1. Operate the fan alone for half a day to dry out the When cleaning the air conditioner, be sure to inside of the unit. turn the SELECTOR knob to the “OFF” position 2. Turn off power and remove plug from wall socket. and disconnect the power cord from the electrical outlet. 3. Clean filter. 1. DO NOT use gasoline, benzine, thinner or other 4. Store (covered) air conditioner in a dry location. chemicals on the air conditioner as these substances may ca
Краткое содержание страницы № 10
Trouble shooting Guide Frequently, a problem is minor and a service call may not be necessary, use this trouble shooting guide for a possible solution. If the unit continues to operate improperly, call Danby’s Toll Free Number 1-800-263-2629 for assistance, or call one of our service depots listed in the enclosed “Authorized Service Depot” listing provided with this unit. Difficulty Possible Cause Suggested Solution Air conditioner will No power to unit. Check connection of power cord to not o
Краткое содержание страницы № 11
LIMITED AIR CONDITIONER WARRANTY This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer. This warranty is available only to the person to whom the unit was originally sold by Danby or by an authorized distributor of Danby, and is non-transferable. TERMS OF WARRANTY Plastic parts, are warranted for thirty (30) days only from purchase date, with no extens
Краткое содержание страницы № 12
Room Air Conditioner The model number of your room air conditioner is found on the serial plate located on the right side of the unit above the power cord. Model • Modèle All repair parts are available for purchase or special order when you visit your nearest service depot. To request service and/or the location of the service depot nearest you, call the TOLL FREE NUMBER: 1-800-263-2629 When requesting service or ordering parts, always provide the DAC7037M following information: • Product Type