Краткое содержание страницы № 1
Bryant
Model 619E
HIGH WALL DUCT-FREE,
Day&Night
SPLIT SYSTEMS Sizes 009-024
Payne
3
Air Conditioning
⁄4 to 2 Tons
PRELIMINARY PRODUCT DATA
619E
538A
538C/D009,012
538S (048 Shown)
DESCRIPTION throughductwork.Also,sincetheoutdoorunitscanbeinstalled
6-in. away from outside walls, coils are protected from vandals
These duct-free split systems cool, heat (heat pump systems
and severe weather.
only) dehumidify, circulate, and filter the air — with minimum
In addition, the compact duct-free split syst
Краткое содержание страницы № 2
The indoor units include protection against freeze-up (heat mount the unit on a wall adjacent to a sloping roof. The wall pumps),highdischargetemperature,andselfdiagnosticstoen- mount kit is also useful in areas of heavy snowfall or where sure reliability. spaceisatapremium.Thewallmountkitmaybeusedwithany outdoor unit. RESTART FUNCTION FOR AUTOMATIC START AFTER A POWER FAILURE eliminates the need to reset the unit after a SUGGESTED USE: power failure. The unit restarts in the same mode that was
Краткое содержание страницы № 3
STANDARD FEATURES AND FIELD-INSTALLED ACCESSORIES HIGH WALL STANDARD FEATURE/FIELD-INSTALLED SYSTEMS ACCESSORY (619B,D) Internal Condensate Pump A Mounting Brackets S Microprocessor Controls S Cleanable Filters S 3-Speed Indoor-Fan Motor S Automatic Indoor-Fan Speed Control S Extensive Diagnostics S Wireless Remote Controllers S Fully Insulated Indoor Unit Cabinet S Automatic Air Sweep S Auto. Restart Function S 24-Hour Automatic Start/Stop Timer S Refrigerant Line Turn Elbow* S High- and Low-Vo
Краткое содержание страницы № 4
MODEL DESCRIPTION OUTDOOR UNITS *009 systems only. †538C,D only. **538A, 538D only. ††538A, 538D, 538S only. \538S only. FAN COIL UNITS *009 systems ony. 4
Краткое содержание страницы № 5
SYSTEM CAPACITIES TOTAL INDOOR SECTIONS NOMINAL SYSTEM SYSTEM OUTDOOR OUTDOOR STANDARD SYSTEM SYSTEM FAN COIL NET NET SOUND SECTION CFM (AT SEER HSPF* TYPE CAPACITY TYPE(S) COOLING HEATING RATING Model 538 HIGH Ckt Qty (Tons) (Btuh) (Btuh)* (Decibels) No. 619 SPEED) 3 ⁄4 — 1 E 009 A 009 286 8,500 — 10.5 — 65 1 — 1 E 012 A 012 358 11,800 — 11.0 — 65 Cooling High Wall 1 Only 1 ⁄2 — 1 E 018 C 018 534 17,300 — 11.5 — 70 2 — 1 E 024 C 024 521 22,600 — 12.0 — 68 3 ⁄4 — 1 E 009 D 009 293 9,000 9,000 10
Краткое содержание страницы № 6
SPECIFICATIONS — 538AAND 538C CONDENSING UNITS UNIT 538C 009 538C 012 538A 018 538A 024 3 1 NOMINAL CAPACITY (Tons) ⁄4 11⁄2 2 OPERATING WEIGHT (lb) 55.0 62.0 150 154 REFRIGERANT TYPE R-22 Control (Cooling) Capillary AccuRaterT Piston at Fan Coil Unit Factory Charge (lb)* 1.5 1.5 4.6 5.3 COMPRESSOR TYPE Tecumseh Copeland Carlyle Rotary Reciprocating Scroll Model EAA090111A EBB120111A AW5517G ZR23K1 OUTDOOR FAN Propeller Type Rpm 1050 1050 850 850 Nominal Air Cfm (High Speed) — — 1720 1720 OUTDOOR
Краткое содержание страницы № 7
SPECIFICATIONS — 538D HEAT PUMP UNITS UNIT 538D 009 012 018 024 3 1 NOMINAL CAPACITY (Tons) ⁄4 11⁄2 2 OPERATING WEIGHT (lb) 60.7 66.6 154 167 REFRIGERANT TYPE R-22 Control (Cooling) Fixed Orifice at Outdoor Unit AccuRaterT Piston at Fan Coil Unit Control (Heating) Fixed Orifice at Outdoor Unit AccuRater Piston at Outdoor Unit Factory Charge (lb)* 1.5 2.0 5.0 5.1 COMPRESSOR TYPE Carlyle Rotary Tecumseh Reciprocating Model EBA095111H EBB130111H AW5519G AW5524G OUTDOOR FAN Propeller Type Propeller, D
Краткое содержание страницы № 8
SPECIFICATIONS — 538S CONDENSING UNITS UNIT 538S 024 048 NOMINAL CAPACITY (Tons) 24 OPERATING WEIGHT (lb) 159 292 REFRIGERANT TYPE R-22 Control (Cooling) TXV in Condensing Unit Factory Charge (lb)* Circuit A 5.0 5.5 Circuit B — 5.5 COMPRESSOR TYPE Copeland Scroll Quantity...Model 1...ZR23K1 2...ZR23K1 Oil (Recharge) (oz) 25 25 OUTDOOR FAN Propeller, Direct Drive Rpm 850 850 Nominal Air Cfm 1720 3900 OUTDOOR COIL Copper Tube,Aluminum Fin Face Area (sq ft)...No. of Rows 6.1...2 12.3...2 Fins/in. 1
Краткое содержание страницы № 9
DIMENSIONAL DRAWING, BASE UNIT — 538C/D009,012 COOLING ONLYAND HEAT PUMP UNITS NOTES: 1. Dimensions in [ ] are in millimeters. 2. Direction of airflow. 3. Center of gravity. 4. Minimumclearances,4in.oncoilsides,24in.onfan side, and 30 in. service side. WEIGHT UNIT 538 Lb Kg C 009 55.0 25.0 C 012 62.0 28.1 D 009 60.7 27.5 D 012 66.5 30.2 9
Краткое содержание страницы № 10
DIMENSIONAL DRAWING — BASE UNIT — 538A018-024 CONDENSING UNITS AB C D E F G H UNIT 538A ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm 1 15 9 7 3 1 1 018 2-1 ⁄8 638.2 3-0 ⁄16 938.2 1-2 ⁄16 369.9 1-4 406.4 1-11 ⁄16 595.3 1-5 ⁄16 436.6 1-5 ⁄2 444.5 1-8 ⁄8 511.2 1 15 9 7 3 1 1 024 2-1 ⁄8 638.2 3-0 ⁄16 938.2 1-2 ⁄16 369.9 1-4 406.4 1-11 ⁄16 595.3 1-5 ⁄16 436.6 1-5 ⁄2 444.5 1-8 ⁄8 511.2 OPERATING JK L M N R S UNIT WT 538A ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in.
Краткое содержание страницы № 11
DIMENSIONAL DRAWING, BASE UNIT — 538D018,024 HEAT PUMP UNITS AB C D E F UNIT 538D ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm 1 15 9 7 3 018 2-1 ⁄8 638.2 3-0 ⁄16 938.2 1-2 ⁄16 369.9 1-4 406.4 1-11 ⁄16 595.3 1-5 ⁄16 436.6 1 15 9 7 3 024 2-1 ⁄8 638.2 3-0 ⁄16 938.2 1-2 ⁄16 369.9 1-4 406.4 1-11 ⁄16 595.3 1-5 ⁄16 436.6 OPERATING GHJ K L M UNIT WEIGHT 538D ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm lb Kg 1 1 5 1 5 018 1-5 ⁄2 444.5 1-8 ⁄8 511.2 1-1 330.2 0-6 ⁄8 168.3 0-
Краткое содержание страницы № 12
DIMENSIONAL DRAWING, BASE UNIT — 538S CONDENSING UNITS ABC D E F G H UNIT 538S Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm 1 15 9 7 3 1 1 024 2-1 ⁄8 638 3-0 ⁄16 938 1-2 ⁄16 370 1-4 406 1-11 ⁄16 595 1-5 ⁄16 437 1-5 ⁄2 445 1-8 ⁄8 511 3 9 1 7 1 5 5 3 048 3-1 ⁄16 945 3-8 ⁄16 1132 1-5 ⁄16 433 1-6 ⁄16 468 2- 6 ⁄2 775 1-7 ⁄8 499 2-5 ⁄8 753 2-8 ⁄16 818 OPERATING JK L M N R S UNIT WEIGHT 538S Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Lb Kg 7
Краткое содержание страницы № 13
DIMENSIONAL DRAWING, BASE UNIT — 619E009,012 FAN COIL UNITS NOTES: WEIGHT A B C UNIT 1. Dimensions are in inches. Dimensions in [ ] are in millimeters. 619E Lb Kg in. mm in. mm in. mm 2. Direction of airflow. 009 18.7 8.5 33.46 850 11.02 280 6.29 160 3. Refrigerant,drainandpowerconnectionsmaybemaderear,leftsideorrightside. 012 24.2 11.0 36.61 930 11.81 300 7.28 185 4. Refrigerant is metered by capillary tubes in the outdoor unit. Insulate both refrig- erant lines. 1 5. Clearancesof3 ⁄29ontopandto
Краткое содержание страницы № 14
DIMENSIONAL DRAWING, BASE UNIT — 619E018,024 FAN COIL UNITS NOTES: UNIT 1. Dimensions in [ ] are in millimeters. WEIGHT 619E 2. Direction if airflow. 018 39 Lb [17.5 Kg] 024 43 Lb [19.5 Kg] 3. Refrigerant, drain, and power connections may be made in unit rear, bottom, left side, or right side. 4. Refrigerant is metered byAccuRaterT device at the fan coil unit on 538Aand 538D018,024 applications.Athermostatic expansion valve is used in the out- door unit on 538S applications. Insulate both refrige
Краткое содержание страницы № 15
ELECTRICAL DATA CONDENSING UNITS OPERATING OPERATING POWER VOLTAGE COMP FAN UNIT VOLTAGE VOLTAGE (Single Ph, 60 Hz) RLA FLA MCA† MOCP† MINIMUM* MAXIMUM* 538A 018 8.0 10.7 15 208/230 187 254 0.70 538A 024 12.9 16.8 25 538C 009 115 104 127 7.6 0.76 12.1 15 538C 012 208/230 187 253 5.5 0.35 8.5 15 LEGEND NOTES: 1. The018and024outdoorunitscontaina24-vtransformer;additional FLA — Full LoadAmps transformers are not required. The 009, 012 outdoor units use high HACR — Heating,Air Conditioning, Refriger
Краткое содержание страницы № 16
ELECTRICAL DATA (cont) FAN COIL UNITS INDOOR OPERATING VOLTAGE* FAN V (Single- UNIT Ph, 60 Hz) Minimum Maximum FLA 619E 009† 115 104 127 — 012† 208/230 187 253 — 009** 115 104 127 — 012** 208/230 187 253 — 018† 024† 208/230 187 253 0.53 018** 024** LEGEND NOTES: 1. The 018, 024, 048 outdoor units contain a 24-v transformer; addi- FLA — Full LoadAmps tionaltransformersarenotrequired.The009,012outdoorunitsuse HACR — Heating,Air Conditioning, Refrigeration 230-v (high voltage) controls. LRA — Locke
Краткое содержание страницы № 17
TYPICAL INSTALLATION — HIGH-WALL SYSTEMS, 9,000 AND 12,000 BTUH (Cooling-Only System Shown) LEGEND NEC — National Electrical Code *Standard. †Field supplied. NOTES: 1. All piping must follow standard refrigerant techniques. 2. Do not install a filter drier in mixed phase liquid line. 3. All wiring must comply with applicable local and national codes. 4. Capillary tube expansion device (cooling-only systems only) is located in the outdoor unit. Both refrigerant lines must be insulated. 5. Wiringan
Краткое содержание страницы № 18
TYPICAL INSTALLATION — HIGH-WALL SYSTEMS, 18,000 AND 24,000 BTUH (Cooling Only System Shown) LEGEND NEC — National Electrical Code Piping Line Voltage 24 V Thermistor *Standard. †Field supplied. NOTES: 1. All piping must follow standard refrigerant piping techniques. 2. All wiring must comply with the applicable local and national codes. 3. Liquid line need not be insulated. 4. Wiringandpipingshownaregen- eral points-of-connection guides only and are not intended for a specific installation. 5. I
Краткое содержание страницы № 19
APPLICATION DATA 1. Unit selection 5. Mounting template Thefancoilunitsarefurnishedwithamountingtemplateto Selectequipmenttoeithermatchorbeslightlylessthanan- mark the location of the mounting brackets, wiring, and re- ticipated peak load. This provides better humidity control, frigeration hole locations. fewer unit cycles, and less part-load operation. 6. Support For units used in spaces with high sensible loads, base Adequate support must be provided to support the weight equipment selection o
Краткое содержание страницы № 20
APPLICATION DATA (cont) 9. Metering devices method.Sinceallrefrigerantlinesareonthelowside a. 009, 012 units —The 009 and 012 units have capillary of the system, it is not normally necessary to add or tubesforrefrigerantmeteringlocatedintheoutdoorcon- remove charge. densing unit. 2) Theseunitshavemixed-phaserefrigerantflowinthe b. 018, 024 units — The 018, 024 units use a piston-type liquidline.DONOTinstallafilterdrierintheliquid metering device located in the indoor unit. line. The liquid line mu