4000E IP Broadband Loop Carrier
Installation Instructions
Document Number IPD4-A2-ZZ40-20
October 2005
Contents
End User License Agreement (Zhone and Affiliates) 2
Introduction 4
Unpacking and Inspecting the Equipment 5
Installation Options 6
Installing Your Management Module 8
Installing Your Interface Module(s) 9
Powering Up Your 4000E BLC 10
Uplink Connections 13
Subscriber Lines 13
Securing the Connecting Cables 16
Configuration and Management 16
Fan Module 17
Specifications 18
Important Sa
Краткое содержание страницы № 2
End User License Agreement (Zhone and Affiliates) Do not install this Software unless you agree to these provisions. Return the Software promptly for a refund if you do not agree. License. Zhone Technologies, Inc. and/or an affiliate ("Zhone") hereby grants you ("User")—either an individual or a single business entity—the non-exclusive right to install, access, run, or interact with ("Use") one copy of the enclosed software (which may have been, or may be, provided on media, as part of a har
Краткое содержание страницы № 3
End User License Agreement (Zhone and Affiliates) Limited Warranty. Zhone warrants that the media containing the Software is free from defects in material and workmanship for ninety (90) days following your purchase of the Software. You may provide written notice of such defect (addressed to Zhone Technologies, Inc., Attention: Customer Service, 7001 Oakport Street @ Zhone Way, Oakland, CA 94621) no later than ten (10) days following expiration of such period and, as your sole and exclusive
Краткое содержание страницы № 4
!" # $
% % $
Introduction The 4000E IP Broadband Loop Carrier (BLC) provides a high capacity and native IP Ethernet foundation for a variety of feature-rich multi-service access mulitplexer modules. The 4000E BLC features a high capacity backplane delivering up to 8 Gbps throughput, and providing a non-blocking architecture for even the highest bandwidth broadband access technologies, such as ADSL2+. It supports a single uplink, management, and swit
Краткое содержание страницы № 5
Unpacking and Inspecting the Equipment Unpacking and Inspecting the Equipment HANDLING PRECAUTIONS FOR ! STATIC-SENSITIVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static control precautions to prevent damage to equipment. If you are not sure of the proper static control precautions, contact your nearest sales or service representati
Краткое содержание страницы № 6
Installation Options The 4000E BLC is designed for installation in a Restricted Access area where admittance is limited to trained and authorized service personel. It may be installed on a tabletop or in a rack. Installation on a Tabletop Insert the four provided rubber bumper screws into the mounting holes at the bottom of the 4000E chassis for surface grip and airflow. Position and secure all connecting cables such that they will not become a tripping hazard or pull loose from the chassis
Краткое содержание страницы № 7
!" # $
% % $
Installation Options Installation in a Rack Using a Phillips Screwdriver, attach the two provided rack mount brackets to the sides of the 4000E with eight of the ten provided bracket screws. There are seven position options for the rack brackets; position them as best suited to the space available for your chassis on the rack being utilized. $"),"- (# ' ('! *#( Mount the chassis onto the rack and secure
Краткое содержание страницы № 8
!" # $
% % $
Installing Your Management Module A management module provides the functional control for the 4000E BLC; the 4000E cannot function without one. There are several different models available. Contact your sales representative. Installing a Management Module An uplink module provides the upstream network connection for the 4000E BLC; a management module cannot function without one. Depending on the management module model that you plan to i
Краткое содержание страницы № 9
!" # $
% % $
!" # $
% % $
Installing Your Interface Module(s) ((/+ ')! '')!0!") 3 Slide the Management Module Firmly into the Chassis. Tighten the fastening screws on the management module faceplate. &( "/#- Installing Your Interface Module(s) Interface modules provide the subscriber connections for a 4000E BLC; up to four interface modules may be installed in the
Краткое содержание страницы № 10
!" # $
% % $
!" # $
% % $
2 Align the interface module with the slot module guides. With the interface module PCB facing up and the interface module model name on the right side of the module faceplate (facing towards you), align the left and right edges of the PCB with the slot module guides of the chosen slot on the 4000E. '')!0!") #1( ')! 3 Slide the interface module fFirmly in
Краткое содержание страницы № 11
2,
2,
Powering Up Your 4000E BLC the back of your chassis. Secure the terminal lug to the chassis with two #10-32 screws. $(#,"- * * *
* 0#'!)%'"'1'#34'#+"(!/ 2 Connect the Ground Wire to a Frame Ground. Ground wire connection can vary from location to location, although typically all equipment in a Central Office is grounded to a common copper bus. 3 Select a Terminal Block. Either terminal block on the back of the 4000E ma
Краткое содержание страницы № 12
2,
2,
2,
2,
and insert the screw into the same "+" terminal from which it was removed. %'-##+"( ' ""5678 #+"( ' ""5'-#() "/#+"( 5 Remove the right-hand screw (labeled "–") from the same terminal block. Slide the ring terminal of your NEGATIVE lead around the shaft of the screw and insert the screw into the same "–" terminal from which it was removed. %'-##+"( 9/("5'-#() "/#+"( 9/("5628
Краткое содержание страницы № 13
!" # $
% % $
Uplink Connections 7 Turn your power source(s) on. The PWR (power) LED on both the interface module and management module faceplates will illuminate solid green to indicate the modules are receiving power. '-#$ ((/+ #1( ')! ')! Uplink Connections No configuration is necessary for Uplink Interface Modules (UIMs) or Media Interface Modules (MIMs) installed on the management module in your 4000E to operate at
Краткое содержание страницы № 14
2,
1 Identify the appropriate RJ21 Connector. Subscriber lines must be connected according to the 4000E slot in which the corresponding interface module was installed. Interface module slots 1–4 run from bottom to top; the corresponding RJ21 ports are directly behind each slot on the back of the chassis (1–4, bottom to top). Each interface module slot on the 4000E has two corresponding RJ21 connectors on the back of the chassis: the RJ21 connectors on the left (A) provide the subsc
Краткое содержание страницы № 15
Subscriber Lines 4 Pull the hook-and-loop fastener strap upward, making sure that it is snug against the connector, then pull the strap back down, such that the hook-and-loop fastener layers stick to one another across the top of the connector. 5 Tuck the tab at the end of the strap down between the connector frames so that it is out of the way of other connections. 6 Screw the right side of the RJ21 cable connector into the jack screw on the right side of the RJ21 connect
Краткое содержание страницы № 16
The LK (Link) LED for each port being connected with a remote modem will illuminate solid or flashing green to indicate a connection has been established. Link up time between interface modules and remote modems can vary from one to five minutes depending on the quality, gauge and distance of the copper cable pair(s) being used. Refer to individual interface module user guides for specific information such as connector pinouts, parameter configurations and distance capabilities.
Краткое содержание страницы № 17
!" # $
% % $
Fan Module Table 1: User Documentation Document Contents Interface module user module installation guides distance and bandwidth capabilities port pinouts (model-specific) parameter defaults parameter configuration options CLI Management User management module initialization instructions Guide command user guide command definitions configuration options common to all management module models configuration options common to all interface
Краткое содержание страницы № 18
Specifications Table 2: Specifications Specification Criteria Environment Operating Temperature: –40° F to 149° F (–40° C to 65° C) Storage Temperature: –40° F to 158° F (–40° C to 70° C) Humidity: 5 % to 95 %, non-condensing Altitude: –200 ft to 16,500 ft (–60 m to 5,000 m) Physical 7" High x 17" Wide x 18" Deep (17.8 cm High x 43.2 cm Wide x 46 cm Deep) 28 lbs (12.73 kg) Power –48 VDC 10 amps maximum Although actual power draw depends upon chassis configuration, a fully loaded chassis ave
Краткое содержание страницы № 19
Important Safety Instructions ! Important Safety Instructions 1 Read and follow all warning notices and instructions marked on the product or included in the manual. 2 Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel. 3 WARNING: This unit supports a redundant 48 VDC power input connection. Disconnect both sources of input power before servicing. 4 T
Краткое содержание страницы № 20
— Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. — Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. — Use caution when installing or modifying telephone lines. — Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. — Do not use the telephone to report a gas leak in the