Краткое содержание страницы № 1
PremierWave XC
User Guide
Part Number 900-598
Revision A June 2012
Краткое содержание страницы № 2
Copyright & Trademark © 2012 Lantronix, Inc. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any form or by any means without the written permission of Lantronix. Lantronix® and PremierWave® are registered trademarks, and DeviceInstaller™ is a trademark of Lantronix, Inc. Ethernet is a trademark of XEROX Corporation. Windows is a trademark of Microsoft Corporation. Linux is a registered trademark of Linus Torvalds. Warranty For detail
Краткое содержание страницы № 3
FCC Part 15.21 Statement Changes or modifications made to this equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC RF Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must be at least 20 cm from the user and
Краткое содержание страницы № 4
Table of Contents Copyright & Trademark ______________________________________________________ 2 Warranty _________________________________________________________________ 2 Contacts __________________________________________________________________ 2 Disclaimer ________________________________________________________________ 2 FCC Part 15.21 Statement ___________________________________________________ 3 FCC RF Radiation Exposure Statement _________________________________________ 3
Краткое содержание страницы № 5
Table of Contents 4: Using DeviceInstaller 26 Accessing PremierWave XC using DeviceInstaller ________________________________ 26 5: Configuration Using Web Manager 29 Accessing Web Manager ____________________________________________________ 29 Device Status Page_____________________________________________________ 30 Web Manager Page Components _____________________________________________ 31 Navigating the Web Manager ________________________________________________ 32 6: Network Setti
Краткое содержание страницы № 6
Table of Contents To Configure Line Settings _______________________________________________ 48 Statistics _____________________________________________________________ 48 To View Line Statistics __________________________________________________ 48 Tunnel Settings ___________________________________________________________ 49 Serial Settings _________________________________________________________ 49 To Configure Tunnel Serial Settings ________________________________________ 50 Packing
Краткое содержание страницы № 7
Table of Contents To Configure an Existing SSL Credential ____________________________________ 69 Trusted Authorities _____________________________________________________ 70 To Upload an Authority Certificate __________________________________________ 70 11: Maintenance and Diagnostics Settings 71 Filesystem Settings ________________________________________________________ 71 File Display ___________________________________________________________ 71 To Display Files ____________________
Краткое содержание страницы № 8
Table of Contents To View and Configure Basic CLI Settings ___________________________________ 83 Telnet Settings _________________________________________________________ 84 To Configure Telnet Settings ______________________________________________ 84 SSH Settings __________________________________________________________ 85 To Configure SSH Settings _______________________________________________ 85 XML Settings _____________________________________________________________ 85 XML: Expo
Краткое содержание страницы № 9
Table of Contents 17: Troubleshooting 102 Diagnostic LED States _____________________________________________________ 102 Problems and Error Messages ______________________________________________ 102 Appendix A: Technical Support 104 Appendix B: Binary to Hexadecimal Conversions 105 Converting Binary to Hexadecimal ___________________________________________ 105 Conversion Table _____________________________________________________ 105 Scientific Calculator ___________________________
Краткое содержание страницы № 10
List of Figures List of Figures Figure 2-1 Product Label ____________________________________________________ 17 Figure 3-1 PremierWave XC Male DB9 DTE Serial Ports ___________________________ 19 Figure 3-2 PremierWave XC Pinout Configuration for RS-232 _______________________ 19 Figure 3-3 PremierWave XC Pinout Configuration for Full Duplex RS-422/485 (4-wire) ___ 19 Figure 3-4 PremierWave XC Pinout Configuration for Half Duplex RS-485 (2-wire) ______ 19 Figure 3-5 PremierWave XC Back
Краткое содержание страницы № 11
List of Tables Table 7-7 Tunnel Disconnect Mode Settings _____________________________________ 55 Table 7-8 Tunnel Modem Emulation Settings ____________________________________ 56 Table 8-1 Terminal on Network and Line Settings _________________________________ 58 Table 8-2 Host Configuration _________________________________________________ 59 Table 9-1 DNS Settings _____________________________________________________ 61 Table 9-2 FTP Settings ____________________________________________
Краткое содержание страницы № 12
1: Using This Guide Purpose and Audience This guide provides the information needed to configure, use, and update the PremierWave XC. It is intended for software developers and system integrators who are deploying PremierWave in their designs. Summary of Chapters The remaining chapters in this guide include: Chapter Description 2: Introduction Main features of the product and the protocols it supports. Includes technical specifications. 3: Installing the PremierWave XC Instructio
Краткое содержание страницы № 13
1: Using This Guide Chapter Description 15: Updating Firmware Instructions for obtaining the latest firmware and updating the PremierWave XC. 16: Branding the PremierWave XC Instructions on how to brand your device. 17: Troubleshooting Describes common problems and error messages. Appendix A: Technical Support Instructions for contacting Lantronix Technical Support. Appendix B: Binary to Hexadecimal Instructions for converting binary values to hexadecimals. Conversions Appen
Краткое содержание страницы № 14
2: Introduction The PremierWave XC is a unique, hybrid Ethernet and GSM/GPRS dual port serial device server which allows remote access to and management of virtually any IT/networking equipment or device connected via Ethernet or GPRS through ‘Serial-tunneling’. Applications include medical equipment, POS terminals or security equipment. Key Features Power Supply: Flexible power options and input voltage range (one barrel connector for 12V power supply, on terminal block connector
Краткое содержание страницы № 15
2: Introduction Protocol Support The PremierWave XC device server contains a full-featured IP stack. Supported protocols include: ARP, IP, UDP, TCP, ICMP, BOOTP, DHCP, Auto IP, Telnet, DNS, FTP, TFTP, SSH, SSL/TLS, and Syslog for network communications and management TCP, UDP tunneling to the serial port TFTP for uploading/downloading files FTP and HTTP for firmware upgrades and uploading/downloading files Troubleshooting Capabilities The PremierWave XC offers a comprehensi
Краткое содержание страницы № 16
2: Introduction Addresses and Port Numbers Hardware Address The hardware address is also referred to as the Ethernet address or MAC address. The first three bytes of the Ethernet address are fixed and identify the unit as a Lantronix product. The fourth, fifth, and sixth bytes are unique numbers assigned to each unit. Sample Hardware Address: 00-80-A3-14-01-18 00:80:A3:14:01:18 IP Address Every device connected to an IP network must have a unique IP address. This address refer
Краткое содержание страницы № 17
2: Introduction Figure 2-1 Product Label Part Number International Mobile Equipment Identity Number MAC Address Revision Country of Origin Manufacturing Date Code PremierWave XC User Guide 17
Краткое содержание страницы № 18
3: Installation of PremierWave XC This chapter describes how to install the PremierWave XC device server. It contains the following sections: Package Contents User-Supplied Items Hardware Components Installing the PremierWave XC Package Contents The PremierWave XC package includes the following items: PremierWave XC device 3-pin Terminal Mating Connector 6-pin Terminal Mating Connector RJ-45 Ethernet Straight Cat5 Cable, 1.5 meter External Antenna, SMA Connecto
Краткое содержание страницы № 19
3: Installation of PremierWave XC Hardware Components The PremierWave XC has two male DB9 serial ports that support RS-232/422/485. Figure 3-1 shows the front panel view of the device. The default serial port settings are 9600 baud, 8 bits, no parity, 1 stop bit, no flow control. Figure 3-1 PremierWave XC Male DB9 DTE Serial Ports Figure 3-2 PremierWave XC Pinout Configuration for RS-232 Figure 3-3 PremierWave XC Pinout Configuration for Full Duplex RS-422/485 (4-w
Краткое содержание страницы № 20
3: Installation of PremierWave XC Back Panel On the PremierWave XC back panel, there is a Barrel Connector for Primary Power (Power 1), 3- Pin Terminal Connector for Secondary Power (Power 2), USB 1, USB 2, RJ-45 Ethernet Port and Reset button as shown in Figure 3-5. Figure 3-5 PremierWave XC Back Panel View The Ethernet Port has two LEDs that indicate the status of the connection as follows: Left LED - Green ON 100 Mbps Link - Green Blink 100 Mbps Activity - Amber ON