Users Manual SX2
2. PRICOM SX-3700WB
This product is a wireless USB device server that will serve USB type peripheral equipment
(a printer, scanner etc.). By using the bundled PRICOM Monitor SX, it is possible to view the
state of the connected printer via a network. In addition it is possible, by using the bundled
PRICOM USB Utility, to share a scanner as a network scanner.
- Windows 2000, Windows XP, or Windows Server 2003 is required to use the network scanning
function.
TIP
- Only one USB d
Краткое содержание страницы № 2
Users Manual SX2 Environment The following are needed for this product. The followings are objects that connect to the network. - PC with wireless communication - USB Cable (A-B Type Connectors) - Printer, Scanner etc. Supported OS Windows 98/98SE/Me, Windows 2000, Windows XP, Windows Server 2003, UNIX/Linux, Macintosh (Mac OS 8.6 - Mac OSX Ver10.2 or newer) Operating Environment - Temperature: +10 C +35 C - Humidity: 20% to 80%RH (no dewing) Storage Environment - Temperature: -10C to 50C
Краткое содержание страницы № 3
Users Manual SX2 Equipment explanation Part name and function Bottom Top Status LED (Orange)Ethernet Address Infra LED Link LED Status LED (The last 6 digits are the product serial (Green) (Green) (Orange) number) Right Side Front Side Power connector USB Port Push Switch The LEDs have the following meaning: Infra LED (Green) Lights when an Infra. mode network connection is established. Link LED (Green) Lights when an OldAdHoc mode network connection is flashed. Lights when an
Краткое содержание страницы № 4
Users Manual SX2 Ethernet Address The Ethernet (MAC) Address of the device is found on the bottom. The last 6 digits are the product’s serial number. - If the Ethernet Address is 00:80:92:18:0E:1A (noted as 008092180E1A) then the product’s serial number is 180E1A. NOTE USB Port Connect a USB Cable (A Type connector) Power Connector Connect AC adapter Push Switch By pushing the push switch, the server can be restored to factory-default settings or do a self-dia
Краткое содержание страницы № 5
Users Manual SX2 1. Please verify that AC adapter is connected and that this product has started normally. Push Switch 2. Push and hold the push switch down. Continue to hold down the push switch for about 5 seconds. The lights will blink and then the infrastructure LED will light. It is now in infrastructure mode. - When using Infrastructure during the initial setup, disable WEP on the access point. - If a mistake is made during the configuration, restore f
Краткое содержание страницы № 6
Users Manual SX2 How to Connect Connect this product to Printer and Network - If this product has been used in another network environment, restore to factory default. TIP This product needs the following to connect to a USB device. USB Cable A-B Type The following example uses a printer as the connected device. 1. Connect the AC Adapter to this product. [ Example ] 2. Plug in the Power cable to the USB device. 3. Connect this product to a USB device. This product uses a type A connector and the
Краткое содержание страницы № 7
Users Manual SX2 Other Functions The following describes of the other functions of this product. Function Assign the IP address automatically using DHCP, BOOTP and RARP - DHCP/BOOTP If a DHCP/BOOTP server is working on your network, the DHCP/BOOTP protocol of this product will assign the IP address to this product. - This product’s DHCP protocol is compatible with RFC2131/2132. - If you use the DHCP function of this product, talk to your administrator. TIP - RARP If a RARP server is working on
Краткое содержание страницы № 8
Users Manual SX2 - Scanner server If you use a USB device, this product will allow you to share the scanner via the bundled PRICOM USB Utility. - The PRICOM USB Utility is compatible with Wndows2000/WindowsXP - This product can connect to one scanner. TIP - Storage server This product supports the NetBEUI/NetBIOS protocol which will allow you to share the USB HDD storage device. - This product does not support printing with the NetBEUI/NetBIOS protocol. - This product can connect to one HDD stor
Краткое содержание страницы № 9
Users Manual SX2 Specification Hardware Specification CPU 32bit RISC CPU Memory RAM :8MByte FlashROM :1MByte Network Interface IEEE802.11b compatible CF card USB Interface Type A port Other Push switch :1 LED :Status(Orange), Link(Green), Infra(Green) PRICOM SX-3700WB 2-9
Краткое содержание страницы № 10
Users Manual SX2 Software Specification Supported Protocol: TCP/IP, NetBEUI/NetBIOS, AppleTalk TCP/IP: Network Layer: ARP, RARP, ICMP, IP, IPv6, ICMP6 Session Layer: TCP, UDP Application Layer: LPD, TELNET, BOOTP, SNMP, HTTP, DHCP, IPP, #9100, DNS, NetBIOS, FTP, POP3, SMTP, SNTP - An IP address should be assigned by using the setup utility. NOTE NetBEUI/NetBIOS: SMB, NetBIOS AppleTalk: AppleTalk Phase2, ELAP, AARP, DDP, AEP, NBP, RTMP, ZIP, ATP, PAP PRICOM SX-3700WB 2-10
Краткое содержание страницы № 11
Users Manual SX2 Using Wireless Communication This product operates at 2.4GHz No radio license is required to use this product. Take note of the following points. Do not use next to the following. - Microwave, scientific instruments, pacemaker or other medical equipment. - Licensed radio station in a factory. - Small power radio station (a non-licensed radio station) The above equipment may use the same band. If you use this product near this equipment, the radio waves from this product and the
Краткое содержание страницы № 12
Users Manual SX2 Wireless Equipment for 2.4GHz band This band of equipment is used by the microwave, industry, science, medical equipment and licensed in room or low power (non licensed)radio stations. - Before you use this equipment, verify that it will not interfere with other broadcasting. - If interference happens, stop using the equipment or change the band. Contact us to discuss ways of avoiding interference (example: create the wall). 2.4 DS 4 2.4 : The frequency of this device is 2.
Краткое содержание страницы № 13
Users Manual SX2 Each wireless product connects directory. Connect this product to the USB device using a USB cable. The PC connects directly to our product in AdHoc mode. NOTE PRICOM SX-3700WB 2-13
Краткое содержание страницы № 14
Users Manual SX2 In Infrastructure mode this product connects through an access point. An Access point allows communication between wired and wireless environments. Connect this product to the USB device using a USB cable. - The following are the two ways to put this product into Infrastructure mode 1. Set the mode to be Infrastructure during the configuration. NOTE 2. After boot, hold down the push switch. PRICOM SX-3700WB 2-14