Ethernet over VDSL2 Converter
VC-201 / VC-202
User’s Manual
Краткое содержание страницы № 2
Trademarks Copyright © PLANET Technology Corp. 2007 Contents subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. The information in this manual is subject to change without notice. All other trademarks belong to their respective owners. Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to
Краткое содержание страницы № 3
If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate your comments and suggestions. FCC Warning This equipment has been tested and found to comply with the regulations for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre
Краткое содержание страницы № 4
WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end users of electrical and electronic equipment should understand the meaning of the crossed- out wheeled bin symbol. Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately. Revision Ethernet Over VDSL2 Converter User’s Manual For Models: VC-201 / VC-202 Rev 1.0 (September 2007) Part
Краткое содержание страницы № 5
TABLE OF CONTENTS 1. Introduction ...............................................................7 1.1 Checklist .............................................................7 1.2 Introduction to Ethernet over VDSL2 Converter ......7 1.3 Key Features .....................................................10 1.4 Specifications ....................................................11 2. Hardware Description ................................................14 2.1 Front Panel .......................
Краткое содержание страницы № 6
3.2.2 Connecting Multiple PCs to an Ethernet LAN ..22 3.3 Connecting VC-202 ............................................23 3.3.1 Connecting Standalone IP device ...............23 3.3.2 Connecting Multiple PCs to an Ethernet LAN ..24 3.4 Chassis Installation and Rack Mounting ...............25 4. POWER INFORMATION ..............................................27 5. Troubleshooting ........................................................28 6. FAQ ..........................................
Краткое содержание страницы № 7
1. Introduction 1.1 Checklist Check the contents of your package for following parts: ● Ethernet over VDSL2 Converter ● Power Adapter ● RJ-11 Telephone line (VC-201 only) ● User’s Manual If any of these pieces are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the original packing material, and use them against to repack the product in case there is a need to return it to us for repair. 1.2 Introduction to Ethernet over VDSL2 Converter P
Краткое содержание страницы № 8
means upstream and downstream rate are the same or similar) – the VDSL port can be RJ-11 connectors or BNC connector. The VC-201/VC-202 can be set to CO mode or CPE mode via a DIP switch. When the VC-20X-CO is used to connect to the other VC-20X-CPE as a standalone pair, up to 100/55Mbps asymmetric data rate within 200m and up to 30/6Mbps asymmetric data rate at 1km. This capability is ideal for use as an Ethernet extender for your existing Ethernet network. PLANET’s VDSL2 Converter sol
Краткое содержание страницы № 9
Краткое содержание страницы № 10
1.3 Key Features The converter provides the following key features: ● Cost-effect VDSL2 CO/CPE bridge solution ● One box design, CO/CPE selectable via DIP Switch ● Complies with IEEE 802.3, IEEE 802.3u and IEEE 802.3x standards ● DMT (Discrete Multi-Tone) line coding ● Half duplex Back pressure and IEEE 802.3x Full Duplex Pause frame flow control ● Built-in POTS/ISDN splitter ● Voice and data communication can be shared on the ex- isting telephone wire simultaneously ● Support up to 1536 by
Краткое содержание страницы № 11
1.4 Specifications Product VC-201 VC-202 Hardware Specification 10/100Base-TX 1 RJ-45, Auto-negotiation and Auto-MDI/MDI-X 1 RJ-11, female 1 BNC, female VDSL Phone Jack connector Ports 1 RJ-11, Built-in splitters for PHONE - POTS/ISDN connection DIP Switch 4 position DIP switch • CO / CPE mode select • Selectable fast and interleaved mode Functionality • Selectable target Data Rate • Selectable target SNR mode • VDSL-DM - ITU-T G.993.1 VDSL Encoding - ITU-T G.997.1 - ITU-T G.993.2 VDSL2
Краткое содержание страницы № 12
• One Power, • 3 for RJ-11/VDSL2 WAN : - Green, LNK/ACT - Green, CO mode LED Indicators - Green, CPE mode • 2 for per RJ-45 10/100Base-TX port - Green, LNK/ACT. - Green, Speed • 10Base-T: 2-pair UTP Cat.3,4,5 up to 100m (328ft) Ethernet • 100Base-TX: 2-pair UTP Cat.5, up to 100m (328ft) Cabling Twisted-pair telephone 50 ohm, RG58A/U, or ISDN wires RG58C/U, RG58/U or VDSL (AWG24 or better) up equivalent to 6.0k feet 200m -> 100/55Mbps 200m -> 100/65Mbps 400m -> 90/40Mbps 400m -> 100
Краткое содержание страницы № 13
10% to 90% , relative humidity, non- Operating Humidity condensing 10% to 90% , relative humidity, non- Storage Humidity condensing Standard Conformance Regulation Compliance FCC Part 15 Class A, CE IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX ITU-T Standards Compliance - G.993.1 (VDSL) - G.997.1 - G.993.2 VDSL2 (Profile 12a Support), Annex A * The actual data rate will vary on the quality of the copper wire or coaxial cable and environment factors. 13
Краткое содержание страницы № 14
2. Hardware Description VC-201 provides 2 RJ-11 ports for voice connection (like telephone or ISDN) and for network line connection. VC-202 provides 1 BNC connector and supports 50 ohm cable with distance of up to 1.6km Both VC-201 and VC-202 provide 1 RJ-45 ports for two different running speed –10Mbps, 100Mbps, in the same converter and automatically distinguish the speed of incoming connection. This section describes the hardware features of these Converters. For easier control of the c
Краткое содержание страницы № 15
● VC-202 Front Panel 2.1.1 LED indicators The rich diagnostic LEDs on the front panel can provide the operating status of individual port and whole system. ● System LED Color Function Lit: Power ON PWR Green Off: Power OFF ● VDSL LED Color Function Indicate that the VDSL link is Lit: established. Fast Indicate that the VDSL link is at training LNK/ Green Blink: status(about 10 seconds) ACT Slow Indicate that the VDSL link is at idle Blink: status Off: Indicate that the port is link down Indi
Краткое содержание страницы № 16
● 10/100Base-TX Port LED Color Function Lit: Indicate that the port is link up. LNK/ Indicate that the converter is actively Green Blink: ACT sending or receiving data over that port Off: Indicate that the port is link down Indicate that the port is operating at Lit: 100Mbps. 100 Green Indicate that the port is link down or Off: 10Mbps. 2.2 The Rear Panel The rear panel of the converter is shown below. ● VC-201 / VC-202 Rear Panel 2.2.1 MODE DIP Switch The converter provides 4 selective trans
Краткое содержание страницы № 17
distance of connectivity. The following is the summary table of transmission setting, bandwidth and distance extensibility tested for AWG 24 (0.5mm) twisted-pair without noise and cross talk. DIP-1 DIP-2 DIP-3 DIP-4 Mode Channel Rate Limit SNR OFF CO Interleave 50/20 Mbps 9dB ON(default) CPE Fast No Limit 6dB ● CO / CPE ▪ CO (Central Office) – the Master device mode, usually the CO device will be located at the data center of ISP or enterprise to link to the backbone. ▪ CPE (customer premis
Краткое содержание страницы № 18
● Rate Limit: (For CO Mode only) User has the ability to select fixed data rate. When Rate Limit is selected, the system will lock the date rate at 50Mbps/20Mbps whenever the calculated SNR margin is higher than 9 dB. This gives best system stability. ● Target SNR (Signal Noise Ratio) Margin: (For CO Mode only) When fixed SNR margin is selected, the system will maintain the SNR margin at 9 dB across all usable loop length. Please power off the converter before making any transmission mod
Краткое содержание страницы № 19
3. Installing and Using VDSL Converter 3.1 Install the Ethernet Over VDSL2 Converter The Converter does not require any software configuration. Users can immediately use any feature of this product simply by attached the cables and plug power on. There is some key limitation on the Ethernet over VDSL2 converter. Please check the following items: ● The device is used for Point-to-Point connection only (Master device to Slave device) and allows data and voice work on the same telephone or I
Краткое содержание страницы № 20
asymmetric backbone, but one converter must be Master (CO mode) and the other one is Slave (CPE mode). Figure 3-1: VC-201 LAN to LAN connection 3.1.2 VC-201 Connect to Multi-Port Master In order, to built up a local Internet in apartment, hotel, campus and hospitality environment. The Multi-port Master (for example, VC-810S VDSL2 Switch) need to be placed In the wiring center (MDF room) and connect to the telephone line system, on the other hand, need to install a Slave (VC-201 CPE) convert