Краткое содержание страницы № 1
®
BitStorm 2600
IP DSLAM
Installation Guide
Document No. 2600-A2-GN20-40
March 2005
Краткое содержание страницы № 2
Copyright 2005 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Ave.
Краткое содержание страницы № 3
Software and Firmware License Agreement ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT. BY USING THE PARADYNE PRODUCT YOU SHOW YOUR ACCEPTANCE OF THE TERMS OF THIS LICENSE AGREEMENT. IN THE EVENT THAT YOU DO NOT AGREE WITH ANY OF THE TERMS OF THIS LICENSE AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT IN ITS ORIGINAL PACKAGING AND YOUR SALES RECEIPT OR INVOICE TO THE LOCATION WHERE YOU OBTAINED THE
Краткое содержание страницы № 4
! Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. This product is intended to be used with a 3-wire grounding type plug — a plug that has a grounding pin. This is a safety feature. Equipment grounding is vital to ensure safe operation. Do not defeat the purpose of the grounding type plug by modifying the plug or using an adapter. Prior to installation, use an outlet tester or a voltmeter to check the AC
Краткое содержание страницы № 5
2 13. The power supply cord for countries other than North America is to be a minimum H05 V V-F type, min. 0.75 mm , 2-conductor and earth ground terminated in an IEC 320 connector on one end, and a plug which is certified for use in the country of installation at the other end. 14. Do not physically stack more than eight (8) 26x1 units high. Physical stability has not been evaluated for stacking higher than eight units, and any configuration greater than eight may result in an unstable (tip-
Краткое содержание страницы № 6
Japan Class A ITE This is a Class A product based on the standard of the Voluntary Control Council for interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. E March 2005 2600-A2-GN20-40
Краткое содержание страницы № 7
Contents Software and Firmware License Agreement . . . . . . . . . . . . . . . . . . . . B About This Guide Document Purpose and Intended Audience . . . . . . . . . . . . . . . . . . . . iii Document Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Related Product Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv 1 Installation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 8
Contents Connecting to Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12 3LEDs LED Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 LED Meanings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 4 Configuration Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Using the CLI . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 9
About This Guide Document Purpose and Intended Audience ® This document is written for technicians who install the BitStorm 2600 IP DSLAM. Document Summary Section Description Chapter 1, Installation Describes the physical installation of the BitStorm 2600 into a rack. Chapter 2, Cabling Describes how to install all cables for the BitStorm 2600. Chapter 3, LEDs Explains the meaning and usage of the front panel LEDs. Chapter 4, Configuration Describes the minimal configuration steps required to
Краткое содержание страницы № 10
About This Guide Related Product Documents Documentation for the BitStorm 2600 IP DSLAM is available on the World Wide Web at www.paradyne.com. Select Support → Technical Manuals. Document Number Document Title 2600-A2-GB21 BitStorm 2600 and GranDSLAM 4200 IP DSLAM Command Line Interface Reference Describes the Command Line Interface (CLI) used to configure and monitor the BitStorm 2600 IP DSLAM. 2600-A2-GB22 BitStorm 2600 and GranDSLAM 4200 IP DSLAM SNMP Reference Contains the informati
Краткое содержание страницы № 11
2600 PORT1-10/100BT PORT2-10/100BT 1000BT PORT3 POTS 1-24 GigE 1 3 5 7 9 11 13 15 17 19 21 23 CONSOLE ALARM 2 4 6 8 10 12 14 16 18 20 22 24 DSL PORTS 1-24 Installation 1 Overview ® The BitStorm 2600 is a family of stackable IP DSLAMs designed for installation in a Central Office (CO), multi-tenant unit (MTU), multi-dwelling unit (MDU), or remote terminal environment. The BitStorm 2600 is available with or without internal POTS splitters. 03-17435 ® The ReachDSL™ Models 2611 and 2614 are int
Краткое содержание страницы № 12
1. Installation Up to eight BitStorm 2600 units can be logically stacked, with aggregation for up to 192 ports of DSL traffic. ReachDSL, ADSL, and SHDSL units can be included in the same stack. Preparation Consider the following before installing the BitStorm 2600 IP DSLAM: Installation Site Your installation site should be well ventilated, clean, and free of environmental extremes. Installation Options The BitStorm 2600 may be: — Mounted with the included mounting brackets in a standar
Краткое содержание страницы № 13
1. Installation Cables Required Table 1-1 shows all the cables that may be required for your installation. Table 1-1. Cable Descriptions Connector Name Connector and Cable For Connecting . . . DSL PORTS 1–24 50-pin RJ21X Telco-type Up to 24 DSL ports to Main straight connector and 50-wire Distribution Frame, punchdown cable. Two cables required, one block, or splitters. for DSL and one for POTS (if POTS 1–24 Up to 24 POTS splitter ports to used). Main Distribution Frame or punchdown block.
Краткое содержание страницы № 14
1. Installation Unpacking the Hardware HANDLING PRECAUTIONS FOR ! STATIC-SENSITIVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static control precautions to prevent damage to equipment. If you are not sure of the proper static control precautions, contact your nearest sales or service representative. The BitStorm 2600 is shipped in a
Краткое содержание страницы № 15
1. Installation Table 1-2. Contents of Hardware Kit Shipped with the BitStorm 2600 Appearance Description Quantity Flat-head screw for attaching 19" mounting brackets to 6 unit 02-17259 Machine screw with captive starwasher (6-32 x 1/4 ″) for 6 attaching 23" mounting brackets to unit Self-retaining nut for racks without threaded holes 4 02-17256 Dress screw (12-24 x 1/2 ″) for use with self-retaining 4 nuts 02-17257 Machine screw with captive starwasher (10-32 x 1/2 ″) 4 for use with ra
Краткое содержание страницы № 16
POTS 1-24 DSL PORTS 1-24 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 1. Installation Mounting Configurations Three basic installation configurations are available: Rack mount – see Installing the Brackets for Rack Mounting on page 1-6 and Installing the BitStorm 2600 Into a Rack on page 1-8. Wall mount – see Installing the BitStorm 2600 on a Wall on page 1-10. Shelf or desktop – see Installing the BitStorm 2600 on a Shelf or Desktop on page 1-12. Mounting Brackets Your B
Краткое содержание страницы № 17
1. Installation 3. Identify six flat-head screws (for 19-inch racks) or six machine screws (for 23-inch racks) provided with the mounting brackets in the hardware kit. 4. Attach the brackets appropriate to your rack size. Tighten all screws firmly. !#
!"!
$ 2600-A2-GN20-40 March 2005 1-7
Краткое содержание страницы № 18
1. Installation Installing the BitStorm 2600 Into a Rack Two types of mounting screws are provided. Use: #10-32 mounting screws for rails with threaded screw holes #12-24 mounting screws and self-retaining nuts for rails with unthreaded screw holes Procedure To install the BitStorm 2600 into a rack: 1. Determine where in the rack you will mount the BitStorm 2600. If your rack does not have threaded screw holes, slip self-retaining nuts onto the rails where the BitStorm 2600 will be fasten
Краткое содержание страницы № 19
PORT1-10/100BT PORT2-10/100BT 1000BT PORT3 POTS 1-24 GigE 1 3 5 7 9 11 13 15 17 19 21 23 CONSOLE ALARM 2 4 6 8 10 12 14 16 18 20 22 DSL PORTS 1-24 24 1 1 POR -10/100BT PORT2-10/100BT 00 T3 GigE POTS 1-24 A 1 3 5 7 9 12 11 13 14 15 16 17 18 20 19 22 21 23 24 L OR CONSOLE LARM 2 4 6 8 10 DS TS T 0B T POR P 1-24 1. Installation 3. Insert and tighten the screws in the top screw positions, then tighten the bottom screws. 03-17436 2600-A2-GN20-40 March 2005 1-9 LINK ACT STATUS ALARM TEST A C LINK
Краткое содержание страницы № 20
1. Installation Installing the BitStorm 2600 on a Wall Wall mounting requires two wood screws suitable for the weight of the fully cabled unit. These are not included. Use at a minimum 1/4-inch (6 mm) diameter screws in 3/4-inch (19 mm) plywood (not drywall). Procedure To install the BitStorm 2600 on a wall: 1. Identify the flat-head screws provided in the hardware kit and the brackets suitable for a 23-inch rack. Two screws are required for each bracket. 2. Orient the unit so that the bott