Dial Up Adapter
Model AW- P
Before attempting to connect, operate or adjust this product, please read
these instructions completely.
Краткое содержание страницы № 2
FCC Note: CAUTION This device complies with Part 15 of the FCC Rules. RISK OF ELECTRIC SHOCK To assure continued compliance follow the attached DO NOT OPEN installation instructions and do not make any unauthorized modifications. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. This equipment has been tested and found to comply REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. with the limits for a class A digital device, pursuant to
Краткое содержание страницы № 3
Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Menu settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Attaching the rack mounting adapters . . . . . . . . . . . . . 19 Parts and their functions . . . . . . . . . . . . . . . . . . . . . . . . . 4 Changing the position of the rear panel . . . . . . . . . . . 19 Control panel . . . . . . . .
Краткое содержание страницы № 4
Parts and their functions Control panel $ 1 2 3 4 5 1 POWER indicator This lights when power is supplied to the main unit and the POWER switch is set to ON. 2 POWER switch This is the unit’s power switch. 3 LCD panel This displays the current statuses and menu settings. 4 Operating keys These keys are used for dialing and to perform menu settings. These keys are also used to operate the pan-tilt head system in direct mode. 2 When any key is operated with the key held down, the function indicated
Краткое содержание страницы № 5
Parts and their functions Rear panel $ 6 89 RS-232C CONTROL OUT TO CAMERA & PAN/TILT HEAD TO MODEM INPUT TO RCB/PC DC 12V IN P5 P4 P3 P2 P1 RS-422 CONTROL OUT > TO CAMERA & PAN/TILT HEAD TO CONTROL PANEL A ? B GND P5 P4 P3 P2 P1 PAN/TILT CAMERA CONTROL IN CONTROL IN OUT PUT :; < = 7 6 RS-232C CONTROL OUT connectors (P1 to P5) : PAN/TILT CONTROL IN connector These connectors are used to connect the pan-tilt head This is used to connect the controller. system controlled with RS-232C. When an AW-RP
Краткое содержание страницы № 6
Connections Turn off the power of all components before proceeding with the connections. Transmitting system connections Connect the control panel Coaxial cable (5C-2V) Set the control panel selector switch to B. 10Base-T cable AW-PS301 Control AW-DU600 RS-232C cable panel Modem AW-PS301 Telephone line OWhen an AW-RP301 or AW-RP501 is being used, OWhen an AW-RP301, AW-RP501 or AW-RP505 is connect the receiving pan-tilt head system to the P1 being used as the controller, an AW-PH350 can not be CO
Краткое содержание страницы № 7
Connections Transmitting system connection procedure 1. Connect the AW-PS301 AC adapter to the DC 12V IN 3 Set this adapter to switch to an external line via a PBX (private branch exchange). connector on this adapter. Press the MENU+ key ( i START ) to change 2 2. Set the control panel selector switch on this adapter. the menu setting item. Set it to A when using an AW-RP605. When “Menu-3 PBX” appears on the LCD panel, use Set it to B when using an AW-RP301, 501, 505, or WV- the ! # START STOP k
Краткое содержание страницы № 8
Connections Receiving system connections $ Connect the pan-tilt head system to the RS-232C CONTROL OUT connector: When an AW-PH300A is used and the connection distance is 10 m or less: Telephone line Modem AW-DU600 AW-CA50A15 AW-PS301 Convertible camera AW-PH300A AW-CA28T9 AW-PS300 When an AW-PH600 is used: Telephone line Modem AW-DU600 AW-PS301 AW-CA50D15 (component) AW-CA50A15 (composite) AW-CH600 AW-CA24U10 P-T CONTROL CAMERA CONTROL AW-PH600 AW-CA16U10 G/L video (BNC cable) Video (BNC cable)
Краткое содержание страницы № 9
Connections $ Connect the pan-tilt head system to the RS-422 CONTROL OUT connector: Use the RS-422 connector when the AW-PH350 is to be used as the pan-tilt head or when the connection distance between this adapter and the pan-tilt head is to exceed 10 m. When an AW-PH350 is used: Telephone line Modem AW-DU600 AW-PS301 AW-CA50C29 (component) AW-CA50T29 (composite) Convertible camera AW-PH350 10 Base-T cable AW-PS300 When an AW-PH300A is used and the connection distance is more than 10 m: Telepho
Краткое содержание страницы № 10
Connections When an AW-PH600 is used and the connection distance is more than 10 m: Telephone line Modem AW-DU600 AW-PS301 AW-CA50D15 (component) AW-CA50A15 (composite) AW-CH600 RS-232C/RS-422 10 Base-T AW-CA24U10 converter cable P-T CONTROL CAMERA CONTROL AW-PH600 AC adapter AW-CA16U10 G/L video (BNC cable) Video (BNC cable) COMPONENT AW-PS600 Refer to the Operating Instructions of the AW-PH600 for details on how to perform the connections for the AW-PH600. 10
Краткое содержание страницы № 11
Connections Receiving system connection procedure 1. 7. Connect the AW-PS301 AC adapter to the DC 12V IN Set the power switch on the modem and the pan-tilt connector on this adapter. head to ON. 2. 8. Connect the TO MODEM connector to the RS-232C “OK” appears on the LCD panel. connector on the modem using the RS-232C cable provided with the modem. Mode : Receiver 3. Connect the telephone line to the line input jack on the OK modem. If the modem is not connected correctly, [---] will appear 4. Co
Краткое содержание страницы № 12
Connections Making a call 5. After control of the pan-tilt head is completed, press the STOP key. Make a call from the AW-DU600 of the transmitting “Hang Up” appears on the LCD display and the system. telephone line is cut. Once the line is cut, “Press Start” appears on the LCD 1. Turn on the power to all units. panel. 2. Use the number keys on this adapter to enter the When ON has been selected for the “Menu-7 Pw-Off” desired number. setting, the power to the pan-tilt head will turn off at the
Краткое содержание страницы № 13
Connections $ Direct mode 1. Control the pan-tilt head system directly using this adapter: AW-DU600 AW-PS301 AW-CA50T29 (composite) AW-CA50C29 (component) Convertible camera 10 Base-T cable AW-PH350 AW-PS300 13
Краткое содержание страницы № 14
Connections Connection procedure 1. 5. Connect the pan-tilt head system to the CONTROL The pan-tilt head system can be controlled in the OUT connector on this adapter. following ways using the operating keys on this adapter. 2. Turn on the power to this adapter and the pan-tilt head system. START STOP 3. Dial Up Adapter settings MENU MENU CLEAR RECALL 1 Set this adapter to direct mode. 1 2 3 M1 M2 M3 Press the MENU+ key ( 2 i START ) to open TELE FAR 4 5 6 the menu settings. M4 M5 BAR When “Menu
Краткое содержание страницы № 15
Connections 2. Control the pan-tilt head system using a control panel or PC: Coaxial cable (5C-2V) 10Base-T cable AW-PS301 AW-DU600 Control AW-CA50T29 panel Convertible camera AW-PH350 AW-PS301 10 Base-T cable AW-PS300 AW-CA50T9 PC AW-PS301 AW-DU600 AW-CA50T29 Convertible camera AW-PH350 10 Base-T cable AW-PS300 AW-RP605 cannot be used as the control panel with direct mode. 15
Краткое содержание страницы № 16
Connections Connection procedure 1. Connect the AW-PS301 AC adapter to the DC 12V IN 3 Set the CONTROL OUT connector according to the connector on this adapter. type of pan-tilt connected and the connection distance. 2. Set the control panel selector switch on this adapter to Press the MENU+ key ( 2 i START ) to change B. the menu setting item. When “Menu-5 Output-1” appears on the LCD panel, 3. 1 Connect the PAN/TILT CONTROL OUT connector use the ! # START STOP keys and select on the control pa
Краткое содержание страницы № 17
Menu settings $ How to perform menu settings O Press the MENU+ key ( 2 i START ) and the first menu item will appear on the LCD. O Press the MENU+ key ( 2 i START ) while a menu item is displayed on the LCD and the display will move to the next item. START STOP O Press the MENU+ key ( 2 i START ) again and the MENU MENU last menu item will appear on the LCD. CLEAR RECALL O Press the MENUj key ( 2 i STOP ) while a menu 1 2 3 M1 M2 M3 item is displayed on the LCD and the display will move to TELE
Краткое содержание страницы № 18
Menu settings The following items are only displayed when this adapter is in Direct mode This setting selects which connector is to be used for the controller when this adapter is in Direct mode. Menu-4 Input RS-232C TO RCB/PC connector (PC used for control) (Initial setting:RS-232C) RS-422 PAN/TILT CONTROL IN connector (control panel used for control) This setting selects which pan-tilt head system is to be controlled by this adapter when this adapter is in Direct mode. The pan-tilt head system
Краткое содержание страницы № 19
Attaching the rack mounting adapters To install the adapter in a rack, use the rack mounting adapters and four of the mounting screws (M4) supplied. Screw Rack mounting adapter Changing the position of the rear panel 1. Remove the three screws from the bottom panel and 3. Use the three screws to firmly secure the rear panel remove the blank panel. where the blank panel was removed from the bottom panel. Screws Screws RS-232C CONTROL OUT TO CAMERA & PAN/TILT HEAD TO MODEM IN PUT TO RCB/PC Blank p
Краткое содержание страницы № 20
Attaching the joint angle adapter To attach the adapter to the controller, use the joint angle adapter, rack mounting adapter and mounting screws (M4 x 8) supplied. Screw Joint angle adapters Rack mounting adapter 20