Краткое содержание страницы № 1
USER’S
GUIDE
2 Gbit/s Fibre Channel
Host Adapters
LSI7102XP-LC, LSI7102LXP-LC
LSI7202XP-LC, LSI7202LXP-LC
LSI7402XP-LC
LSI7202EP-LC, LSI7202EP
LSI7402EP-LC, LSI7402EP
August 2005
Version 2.1
®
DB15-000264-02
Краткое содержание страницы № 2
This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used by or disclosed to third parties without the express written permission of an officer of LSI Logic Corporation. LSI Logic products are not intended for use in life-support appliances, devices, or systems. Use of any LSI Logic product in such applications without written consent of the appropriate LSI Logic officer is prohibited. Document DB15-000264-02, August 2005 This docum
Краткое содержание страницы № 3
Preface This book is the primary reference and user’s guide for the LSI Logic family of 2 Gbit/s Fibre Channel host adapter boards. It contains a complete functional description of these boards as well as complete physical and electrical specifications. LSI Logic uses Class 1 transceivers on the host adapter boards contained in this user’s guide. Audience This document assumes that you have some familiarity with Fibre Channel protocol and related support devices and will benefit persons installing
Краткое содержание страницы № 4
Related Publications LSIFC929X Dual Channel Fibre Channel I/O Processor Technical Manual, Document No. DB14-000202-01 LSIFC919X Single Channel Fibre Channel I/O Processor Technical Manual, Document No. DB15-000225-01 Fusion-MPT™ Device Management User’s Guide, Volume 1.2, Document No. DB15-000186-01 PCI Local Bus Specification, Rev. 2.2 PCI-X/133 Local Bus Specification, Rev. 1.0a PCI Express Base Specification, Rev. 1.0a Revision Record Revision Date Remarks 1.0 10/02 Preliminary release 2.0 04/03
Краткое содержание страницы № 5
Contents Chapter 1 Installation Procedures 1.1 General Description 1-1 1.2 Quick Installation Procedure 1-2 1.3 Detailed Installation Procedure 1-3 1.3.1 Before You Start 1-3 1.3.2 Installing the Host Adapter 1-3 Chapter 2 2 Gbit/s FC Host Adapter Characteristics 2.1 General Description 2-1 2.2 Features 2-3 2.2.1 PCI-X Interface 2-3 2.2.2 PCI Express Interface 2-4 2.2.3 FC Interface 2-4 2.3 Physical Environment 2-4 2.3.1 Electrical Characteristics 2-5 2.3.2 Thermal, Atmospheric Characteristics 2
Краткое содержание страницы № 6
2.8 Physical Characteristics 2-9 2.8.1 LSI7102XP-LC Host Adapter Configuration 2-9 2.8.2 LSI7102XP-LC Connector and Indicator LED 2-10 2.8.3 LSI7102LXP-LC Host Adapter Configuration 2-12 2.8.4 LSI7102LXP-LC Connector and Indicator LED 2-13 2.8.5 LSI7202XP-LC Host Adapter Configuration 2-14 2.8.6 LSI7202XP-LC Connectors and Indicator LEDs 2-15 2.8.7 LSI7202LXP-LC Host Adapter Configuration 2-16 2.8.8 LSI7202LXP-LC Connectors and Indicator LEDs 2-17 2.8.9 LSI7202EP-LC Host Adapter Configuration 2-18 2.
Краткое содержание страницы № 7
Chapter 4 BIOS Features 4.1 LSI Logic Boot BIOS 4-2 4.1.1 LSI Logic Boot BIOS Features 4-2 4.1.2 BIOS Overview 4-2 4.1.3 LSI Logic BIOS Boot Specification (BBS) 4-2 4.2 Starting the LSI Logic Boot BIOS Configuration Utility 4-3 4.3 Using the LSI Logic Boot BIOS CU 4-3 4.4 Main Menu 4-3 4.4.1 Adapter Properties Menu 4-4 4.4.2 Persistent ID Menu 4-4 4.4.3 Device Properties Menu 4-5 4.4.4 Boot Adapter List Menu 4-5 4.4.5 Global Properties Menu 4-6 4.5 Exiting the LSI Logic Boot BIOS Configuration Util
Краткое содержание страницы № 8
viii Contents Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.
Краткое содержание страницы № 9
Figures 1.1 Hardware Connections for the LSI Logic Host Adapter 1-4 1.2 Inserting the LSI Logic Host Adapter 1-5 2.1 LSI7102XP-LC Host Adapter Configuration 2-10 2.2 LSI7102XP-LC Connector and Indicator LED 2-11 2.3 LSI7102LXP-LC Host Adapter Configuration 2-12 2.4 LSI7102LXP-LC Connector and Indicator LED 2-13 2.5 LSI7202XP-LC Host Adapter Configuration 2-14 2.6 LSI7202XP-LC Connectors and Indicator LEDs 2-15 2.7 LSI7202LXP-LC Host Adapter Configuration 2-16 2.8 LSI7202LXP-LC Connectors and Indicat
Краткое содержание страницы № 10
x Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.
Краткое содержание страницы № 11
Tables 2.1 LSI Logic 2 Gbit/s FC Host Adapter Descriptions 2-2 2.2 Hardware and Software Requirements 2-3 2.3 Maximum Power Requirements 2-5 2.4 LED Appearance to Represent Link Status 2-7 2.5 PCI System ID Values 2-8 2.6 PCI Subsystem ID Values 2-8 2.7 LSI7102XP-LC Link Activity/Link Fault LEDs 2-11 2.8 LSI7102LXP-LC Link Activity/Link Fault LEDs 2-13 2.9 LSI7202XP-LC Link Activity/Link Fault LEDs 2-15 2.10 LSI7202LXP-LC Link Activity/Link Fault LEDs 2-17 2.11 LSI7202EP-LC Link Activity/Link Fa
Краткое содержание страницы № 12
xii Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.
Краткое содержание страницы № 13
Chapter 1 Installation Procedures This chapter contains general information about the LSI Logic 2 Gbit/s family of Fibre Channel (FC) host adapters. It also provides host adapter installation instructions. This chapter describes these topics in the following sections: • Section 1.1, “General Description” • Section 1.2, “Quick Installation Procedure” • Section 1.3, “Detailed Installation Procedure” 1.1 General Description LSI Logic provides high-performance, cost-effective 2 Gbit/s FC controllers
Краткое содержание страницы № 14
1.2 Quick Installation Procedure This section provides an overview of the installation procedure. If you are an experienced computer user with prior host adapter installation and FC setup experience, this section may describe the procedure sufficiently. If you prefer more detailed guidance for installing the host adapter, proceed to Section 1.3, “Detailed Installation Procedure.” For safe and proper installation, refer to the user’s manual supplied with your computer and perform the following ste
Краткое содержание страницы № 15
1.3 Detailed Installation Procedure This section provides step-by-step instructions for installing the host adapter. If you are experienced in these tasks, you may prefer to use Section 1.2, “Quick Installation Procedure.” 1.3.1 Before You Start Before starting, look through the following task list to get an overall idea of the steps you will perform. If you are not confident you can perform the tasks as described here, LSI Logic recommends getting assistance. Each FC host adapter channel that y
Краткое содержание страницы № 16
connector contacts. LSI Logic recommends using a static ground strap. Step 5. Locate the slots for PCI plug-in board installation. Refer to the user’s manual supplied with your computer to confirm the location of the PCI slots. This host adapter requires a 32-bit or 64-bit PCI slot that allows bus master operation. If a 32-bit PCI slot is used, the portion of the J1 connector opposite the bracket remains uninserted. Refer to Table 1.2 for details. Note: For this host adapter to function as a 64-b
Краткое содержание страницы № 17
Step 7. Carefully insert PCI Bus edge connector J1 (see Figure 1.1)of the host adapter into the PCI slot. Make sure the edge connector is properly aligned before pressing the board into place, as shown in Figure 1.2. The bracket around the Small Form-Factor Pluggable (SFP) transceiver cages should fit where you removed the blank panel. Figure 1.2 Inserting the LSI Logic Host Adapter Bracket Screw 32-Bit PCI Slots 64-Bit PCI Slots Step 8. Secure the board with the bracket screw (see Figure 1.2),
Краткое содержание страницы № 18
1-6 Installation Procedures Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.
Краткое содержание страницы № 19
Chapter 2 2 Gbit/s FC Host Adapter Characteristics This chapter provides specific details about the physical environment associated with the 2 Gbit/s family of FC host adapters. This chapter includes the following sections: • Section 2.1, “General Description” • Section 2.2, “Features” • Section 2.3, “Physical Environment” • Section 2.4, “Operational Environment” • Section 2.5, “PCI System ID Values” • Section 2.6, “PCI Subsystem ID Values” • Section 2.7, “Unique World Wide Name” • Section 2.8, “
Краткое содержание страницы № 20
This manual serves as a step-by-step guide during the installation of your LSI Logic host adapter. Table 2.1 lists the 2 Gbit/s FC host adapters discussed in this User’s Guide. Table 2.1 LSI Logic 2 Gbit/s FC Host Adapter Descriptions Adapter Description LSI7102XP-LC 2 Gbit/s, PCI-X, single-port, standard height bracket, optical LSI7102LXP-LC 2 Gbit/s, PCI-X, single-port, low-profile bracket, optical LSI7202XP-LC 2 Gbit/s, PCI-X, dual-port, standard height bracket, optical LSI7202LXP-LC 2 Gbit/s,