Краткое содержание страницы № 1
IPL T S Series
®
IP Link Ethernet Control Interfaces
68-1218-01 Rev. D
12 08
Краткое содержание страницы № 2
Precautions Safety Instructions • English Warning Power sources • This equipment should be operated only from the power source indicated on the product. This This symbol is intended to alert the user of important operating and maintenance equipment is intended to be used with a main power system with a grounded (neutral) conductor. The (servicing) instructions in the literature provided with the equipment. third (grounding) pin is a safety feature, do not attempt to bypass or disable it. Th
Краткое содержание страницы № 3
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The Class A limits are designed to provide reasonable protection against harmful interference when the equipment i
Краткое содержание страницы № 4
ii IPL T S Series
Краткое содержание страницы № 5
IPL T S2 COM 100 R 2 1 AC LT INK 2 4 IPL T S2 COM 100 R 1 LINK 2 ACT ® ® IPL T S2 IPL T S2 COM COM 100 100 R 1 LINK R 1 LINK 2 ACT 2 ACT ® IPL T S2 COM 100 R 1 LINK 2 ACT T X RX R T SC T S Quick Start — IPL T S Series Step 1 Step 4 Turn power off and disconnect the device from Connect RS-232 cables from the IPL T S Series its power source. unit to the audio video (A/V) devices. Step 2 Step 5 Mount the IPL T S Series unit: Connect power cords and apply power in the following order: • on a pr
Краткое содержание страницы № 6
Quick Start — IPL T S Series, cont’d QS-2 IPL T S Series • Quick Start
Краткое содержание страницы № 7
Table of Contents Chapter One • Introduction ......................................................................................................1-1 About This Manual ....................................................................................................................1-2 About the IPL T S Series Interface ..................................................................................1-2 IPL T S1 control interface .............................................................
Краткое содержание страницы № 8
Table of Contents, cont’d File Management page ..........................................................................................................3-14 Configuration using DataViewer ...................................................................................3-15 Chapter Four • Communication and Control ...............................................................4-1 Programmer’s Guide for Telnet and Web Browsers ..............................................4-2 Using the command/
Краткое содержание страницы № 9
IPL T S Series Chapter One 1 Introduction About This Manual About the IPL T S Series Interface Features
Краткое содержание страницы № 10
Introduction About This Manual This manual describes the function, installation, configuration, and operation of the Extron IPL T S Series interface devices which are shown below. About the IPL T S Series Interface The Extron IPL T S Series interface devices integrate network connectivity into audio/video (A/V) systems. Installing an IPL T S Series interface into an A/V network gives users the ability to remotely monitor and control projectors, flat-panel displays, switchers, and other
Краткое содержание страницы № 11
® Each IPL T S Series interface comes with Extron’s IP Link technology including: • A built-in Web server • A set of Web pages that can be used to configure the device ® • Flash memory to store Extron’s GlobalViewer application and A/V equipment device drivers • Compatibility with Extron’s free GlobalViewer application which provides a graphical user interface with which to remotely monitor and control your A/V network devices The IPL T S Series interface devices support the following
Краткое содержание страницы № 12
Introduction, cont’d Web-based A/V asset management — When used with GlobalViewer software, the IPL T S interfaces provide a powerful, flexible way to manage, monitor, and control projectors, flat-panel displays, and other devices using a standard Ethernet network. Integral, high performance Web server — Each IPL T S interface features a built-in Web server with memory available for storing device drivers, GlobalViewer, and development of your own Web pages using “off-the-shelf” Web author
Краткое содержание страницы № 13
IPL T S Series Chapter Two 2 Installation and Operation Installation Overview Mounting the IPL T S Interface Rear Panel Features and Cabling Operation
Краткое содержание страницы № 14
Installation and Operation Installation Overview To install and set up an IPL T S interface, follow these steps: 1. Turn all of the equipment off. Make sure that the video sources (DSS, cable boxes, or other devices), the IPL T S unit, the output devices (monitors, VCRs, projectors, etc.) and the serial controller are all turned off and disconnected from the power source. 2. Mount the IPL T S interface. See “Mounting the IPL T S Interface”, below. 3. Attach the cables. See “Connecting the
Краткое содержание страницы № 15
® ® IPL T S2 IPL T S2 COM COM 100 100 R 1 LINK R 1 LINK 2 ACT 2 ACT ® IPL T S2 COM 100 R 1 LINK 2 ACT Mounting options All units are easily mounted in a rack, under a desk or podium, or on a projector mount. Mounting kits and IPL T S Series device compatibility are shown in the table below. Mounting Type Kit PN S1 S2 S4 S6 Under-furniture mount 70-077-01 • Under-furniture mount 70-212-01 • • • Projector mount 70-077-04 • Projector mount 70-217-01 • • • Rack mount 1U 9.5” D rack s
Краткое содержание страницы № 16
® ® IPL T S2 IPL T S2 COM COM 100 100 R 1 LINK R 1 LINK 2 ACT 2 ACT MDA SERIES DISTRIBUTION AMPLIFIER Installation and Operation, cont’d Figure 2-2 — Mounting the interface on the standard shelf Furniture or projector mounting The following furniture and projector mount kits are available: • PN 70-077-01 Furniture mount kit (for IPL T S1) • PN 70-077-04 Projector mount kit (for IPL T S1) • PN 70-212-01 Furniture mount kit (for IPL T S2, S4, S6) • PN 70-217-04 Projector mount kit (for
Краткое содержание страницы № 17
IPL T S2 COM R 1 LINK 100 2 2 4 ACT IPL T S2 COM 100 R 1 LINK 2 ACT TX RX RTS CTS Projector Mounting Mounting Bolt Bracket Furniture Mount Digital Projector Projector Mount Figure 2-3 — Mounting the interface Rear Panel Features and Cabling All connections, including power, control, input, and output, are on the back panel of the IPL T S interface. See figures 2-4, 2-5, 2-6, 2-7 for details on each model. 10 00-05-A6-00-00-01 12V 0.5 A COM1 LAN 1 6 2 3 4 Figure 2-4 — I
Краткое содержание страницы № 18
Installation and Operation, cont’d 10 6 COM1 00-05-A6-00-00-06 LAN POWER COM2 12V COM3 COM4 COM5 COM6 .5A MAX TX RX TX RX TX RX TX RX 3 5 7 1 2 4 Figure 2-7 — IPL T S6 interface back panel Power Power connection — Plug the unit’s external 12 VDC power supply into this a connector. The power supply is provided with the unit. When you are connecting the power supply, voltage polarity is extremely C important. Applying power with incorrect voltage polarity could damage the power s
Краткое содержание страницы № 19
Ethernet/LAN LAN Activity LED — A blinking yellow LED indicates LAN activity. b LAN connector — An RJ-45 connector for a network connection. Use an c Ethernet straight-through cable to connect to a switch, hub, or router, or an Ethernet crossover cable to connect directly to a PC. COM1 00-05-A6-00-00-02 Straight-through Cable (for connection to a switch, hub, or router) LAN End 1 End 2 POWER COM2 12V COM1 COM2 Pin Wire Color Pin Wire Color .5A MAX 1 white-orange 1 white-orange
Краткое содержание страницы № 20
Installation and Operation, cont’d Factory default protocol for the control interface is: • RS-232 • 9600 baud • no parity • 8 data bits • 1 stop bit • pacing = 0 ms • handshaking = off Communication to an attached device can be done through the IPL T S Series ™ device’s default Web pages or by using Extron’s Simple Instruction Set (SIS ) commands. The rear panel 9-pin D connector COM ports have the following pin assignments: Pin Function RS-232 RS-422 RS-485 2 Receive Data/Receive D