Краткое содержание страницы № 1
Extended
®
Ethernet
AT-MC601
AT-MC602
◆
Installation
and
User’s Guide
PN 613-50538-00 Rev B
Краткое содержание страницы № 2
Copyright © 2004 Allied Telesyn, Inc. www.alliedtelesyn.com All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc. Microsoft is a registered trademark of Microsoft Corporation, Netscape Navigator is a registered trademark of Netscape Communications Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Te
Краткое содержание страницы № 3
Electrical Safety and Emission Statement Standards: This product meets the following standards. U.S. Federal Communications Commission Declaration Of Conformity Manufacture Name: Allied Telesyn, Inc. (www.alliedtelesyn.com) Declares that the product: Extended Ethernet Model Numbers: AT-MC601, AT-MC602 This product complies with FCC Part 15B, Class A Limits: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause
Краткое содержание страницы № 4
AT-MC601 and AT-MC602 Installation and User’s Guide RFI Emission EN55022 Class A, FCC Part 15 Class A, C-TICK 1 Immunity EN55024 2 Electrical Safety EN60950, UL60950, FCC Part 68 3 Important: Appendix C contains translated safety statements for installing this equipment. When you see the , go to Appendix C for the translated safety statement in your language. Wichtig: Anhang C enthält übersetzte Sicherheitshinweise für die Installation dieses Geräts. Wenn Sie sehen, schlagen Sie in Anhang
Краткое содержание страницы № 5
Contents Electrical Safety and Emission Statement ............................................................................................................................................... 3 Preface ...................................................................................................................................................................................................................... 7 How This Guide is Organized ...................................................
Краткое содержание страницы № 6
AT-MC601 and AT-MC602 Installation and User’s Guide Installing the AT-MC602 Provider Unit .........................................................................................................................................................30 Cabling the Provider Unit......................................................................................................................................................................... 32 Powering On the Provider Unit ..........................
Краткое содержание страницы № 7
Preface This guide contains instructions on how to install and configure the AT-MC601 and AT-MC602 Extended Ethernet units. How This Guide is Organized This manual contains the following chapters and appendices: Chapter 1, Product Description, describes the features and components of the network extenders. Chapter 2, Installation, contains installation instructions for each unit. Chapter 3, Configuration, explains how to use the configuration software. The AT-S57 software is used to configur
Краткое содержание страницы № 8
AT-MC601 and AT-MC602 Installation and User’s Guide Document Conventions This document uses the following conventions: Note Notes provide additional information. Warning Warnings inform you that performing or omitting a specific action may result in bodily injury. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data. 8
Краткое содержание страницы № 9
AT-MC601 and AT-MC602 Installation and User’s Guide Contacting Allied Telesyn Technical Support This section provides Allied Telesyn contact information for technical support as well as sales or corporate information. Online Support You can request technical support online by accessing the Allied Telesyn Knowledge Base from the following web site: http://kb.alliedtelesyn.com. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously
Краткое содержание страницы № 10
Chapter 1 Product Description The AT-MC601, AT-MC602 Extended Ethernet products are designed to transmit data at very high speeds over unshielded pairs of copper wires using VDSL technology on your existing telephone line. Summary of Features ❑ VDSL (Very high-bit-rate Digital Subscriber) Line port ❑ PSTN (Public Switched Telephone Network) port ❑ 10/100 Mbps Ethernet port with an RJ-45 connector ❑ Auto MDI/MDI-X ❑ Auto-Negotiation for speed and duplex mode (IEEE 803.3u- compliant) ❑ Status
Краткое содержание страницы № 11
AT-MC601 and AT-MC602 Installation and User’s Guide Overview These devices can be used in multi-dwelling units (MDU), multi-tenant buildings (MTU), and in the hospitality industry, such as airports, hotels, and convention centers. These units are sold in pairs with the AT-MC601 functioning as the subscriber and the AT-MC602 functioning as the provider. In an MDU, such as a university dormitory, the subscriber unit would be installed in each room and connected to a provider unit through the
Краткое содержание страницы № 12
AT-MC601 and AT-MC602 Installation and User’s Guide Location of Components Figure 2 illustrates the front panels of the AT-MC601 and AT-MC602 network extenders. 10BaseT/ LINE 100BaseTX Ethernet VDSL Line LINK ERR ACT LINK Status LEDs PWR PSTN LEDs MGMT AT-MC601 VDSL EXTENDED ETHERNET Management Port VDSL Line Port Ethernet Port PSTN Port 10BaseT/ LINE 100BaseTX Ethernet VDSL Line LINK ERR ACT LINK Status LEDs PWR PSTN MGMT LEDs AT-MC602 VDSL EXTENDED ETHERNET Figure 2 Front Panels Figure 3 i
Краткое содержание страницы № 13
AT-MC601 and AT-MC602 Installation and User’s Guide Hardware Features The following sections describe these hardware features of the AT-MC601 and AT-MC602 network extenders: ❑ VDSL Line port ❑ PSTN port ❑ 10/100 Mbps twisted pair Ethernet port ❑ Status LEDs ❑ Management port ❑ Management cable ❑ 12V DC power supply input port ❑ External AC/DC power adapter Note The AT-MC602 unit can only be installed in an AT-MCR12 chassis. VDSL Line Port The VDSL Line port allows you to connect the AT-MC601 Su
Краткое содержание страницы № 14
AT-MC601 and AT-MC602 Installation and User’s Guide PSTN Port The PSTN port allows you to connect the AT-MC601 Subscriber unit to a telephone and the AT-MC602 Provider unit to the outside telco box. This port features an RJ-11 connector. Table 2 lists the RJ-11 port pinouts and their assignments. Table 2 PSTN - RJ-11 Port Pinout Pin Assignment 1 pass-through 1/6 2 pass-through 2/5 3 Ethernet and phone ring 4 Ethernet and phone tip 5 pass-through 5/2 6 pass-through 6/1 10/100 Mbps The AT-MC601
Краткое содержание страницы № 15
AT-MC601 and AT-MC602 Installation and User’s Guide Auto-Negotiation.The network extenders Auto-Negotiate the speed and duplex mode of the Ethernet link, so that the link comes up in the highest performance configuration supported by both ends. Half- and Full-duplex Mode.Duplex mode refers to the way an end-node sends and receives data on the network. An end-node can operate in either half- or full-duplex mode, depending on its capabilities. An end-node that is operating in half-duplex mode
Краткое содержание страницы № 16
AT-MC601 and AT-MC602 Installation and User’s Guide Status LEDs The AT-MC601 and AT-MC602 network extenders feature the following status LEDs: ❑ Power ❑ Ethernet: link and activity ❑ VDSL Line: link and error Table 4 defines the LEDs for the AT-MC601 and AT-MC602 network extenders. Table 4 Status LEDs LED Color Description PWR Green Power is applied to the unit. 10/100Base-TX Port LINK Green A link has been established on the port. ACT Green Data is being received on the ports. LINE Port ERR
Краткое содержание страницы № 17
AT-MC601 and AT-MC602 Installation and User’s Guide MGMT Port The management port features a 8-pin DIN connector for connecting the network extenders to your laptop or PC-compatible computer for configuration using the provided management cable. Management The management cable included with the AT-MC602 Provider unit features a 9-pin RS-232 connector to attach to your computer and an Cable 8-pin DIN connector to attach to the network extender. 8-pin DIN connector 9-pin RS-232 connector Figu
Краткое содержание страницы № 18
AT-MC601 and AT-MC602 Installation and User’s Guide AC Power Supply Input Port The network extender has a single DC power supply socket on the back panel. The unit does not have a power switch. To turn the network extender ON or OFF, you connect or disconnect the power cord. External AC/DC An external AC/DC power adapter is included with the network extender for desktop or wall-mount operation. The power adapter supplies 12V Power Adapter DC to the network extender. Allied Telesyn supplies a
Краткое содержание страницы № 19
AT-MC601 and AT-MC602 Installation and User’s Guide Software Features The AT-S57 software used to configure the AT-MC601 and AT-MC602 network extenders has the following features: ❑ Determine the VDSL link status ❑ Set the upstream and downstream data transfer rates ❑ Monitor the status of the VDSL parameters on both the local and remote units ❑ Monitor the status of the Ethernet parameters on both the local and remote units ❑ Link recovery Note The features listed here are further described
Краткое содержание страницы № 20
Chapter 2 Installation This chapter contains the installation procedures for the network extenders. The installation process is described in the following sections: ❑ Installation Safety Precautions ❑ Selecting a Site for the Network Extender ❑ Required Cables ❑ Unpacking the Network Extender ❑ Installing the AT-MC601 Subscriber Unit ❑ Installing the AT-MC602 Provider Unit ❑ Warranty Registration 20