Краткое содержание страницы № 1
MOBILE AIR CONDITIONER
USER’S MANUAL
Read Rules for Safe Operation and Instructions Carefully
Краткое содержание страницы № 2
CONTENTS 1. SAFETY RULES …………………………………………………………...2 2. NAME OF PARTS ………………………………………………………...3 3. ACCESSORIES …………………………………………………………….3 4. OPERATION PANEL OF THE AIR CONDITIONER ……………..…… 4-5 5. OPERATION AND INDICATION SECTIONS OF REMOTE CONTROLLER ……………………………………………….………..6-7 6. OPERATION METHOD………………………………………….…..… 8-10 7. KEY-OPERATING INSTRUCTION FOR THE AIR CONDITIONER..…………………………………………………..…. 11-13 8. INSTALLATION ..………………………………………………......… 13-15 9. MAINTENANCE …………………………………
Краткое содержание страницы № 3
SAFETY RULES 1. Do not connect unit to any AC socket in disrepair. 2. Do not use in the following locations: A: Next to source of fire B: An area where oil is likely to splash. C: An area exposed to direct sunlight. D: An area where water is likely to splash. E: Near a bath, a shower or a swimming pool. 3. Never insert your fingers or any foreign objects into the air outlet. Take special care to warn children of these dangers. 4. Always store the unit upright in order to maintain th
Краткое содержание страницы № 4
NAME OF PARTS REAR COVER FRONT COVER AIR INLET OPERATION PANEL AIR OUTLET AIR OUTLET WATER PUMP DRAIN HOSE REMOTE CONTROLLER AIR INLET AIR INLET POWER CORD CONTINUOUS DRAIN HOSE CASTER REAR VIEW SIDE VIEW FRONT VIEW Fig.1 ACCESSORIES QUANTITY PARTS PARTS NAME DUCT ASSEMBLY 1 INSTALLTION PLATE WATER PUMP DRAIN HOSE 1 Fig.2 Check all the accessories are included in the package and please refer to the installation instr
Краткое содержание страницы № 5
OPERATION PANEL OF THE AIR CONDITIONER i. A model display indicators (with electricity heating): ly light Set e e Fig.3 ii. A model display indicators (only cooling): light Set Fig.4 5
Краткое содержание страницы № 6
● B model display indicators : F Receiver Fig.5 DISPLAY: Locked indicate Auto mode indicate Heating mode indicate Fan speed mode indicate F Swing indicate Cooling mode indicate Digital display Timer indicate Fig.6 Note: 1.The AutoCoolingHeatingDry mode indicators will not display in the Fan mode. 2.The relevant display light according the set content by remote controller. 3.Air conditioner
Краткое содержание страницы № 7
OPERATION OF THE REMOTE CONTROL Display Screen ON/OFF Button For setting display Press this button to start / stop air conditioner. Sleep Button Temp Adjustment Buttons For setting sleep Press “ ▼” to decrease temp. Press “ ▲” to increase temp. SET TEMP function. AU TO PR O G R A M Mode selection Button For selecting Fan speed button AUTO HEAT SLEEP ON/OFF For selecting indoor fan COOL DRY speed: Auto AUT Medium SWEEP TEMPERATURE High
Краткое содержание страницы № 8
Remote Controller Display Operating Mode Selection AUH Display Signal Emission Timer setting Display It appears when Symbol Display HEAT AUTO pressing the AUH It appears when key is add in HEAT control signal is ON timer DRY COOL mode. emitted. FAN OFF timer PROGRAM Wind Speed Selection Program Display SET TEMP AUT PROGRAM Timer canceled Auto AUT High speed Time Display Displays the time of Medium speed clock or timing Low speed ON/OFF.
Краткое содержание страницы № 9
OPERATION METHOD AUTO, HEAT, COOL,FAN and DRY operation Setting Operation Mode Auto Heat Sweep 1 Cool Dry SET TEMP AUTO Temp Adjustment Buttons Press “ ▲ ” “ ▼ ” buttons to set 2 temp as needed. Switch On SLEEP ON/OFF Press ON/OFF button to start air 3 conditioner. TEMPERATURE Airflow selection Press “FAN SWEEP” button to select 4 airflow direction. MODE FAN SPEED Setting Fan Speed AUH FAN SWEEP Four speeds can be selected: A
Краткое содержание страницы № 10
Clock Setting SET TEMP Press “TIME” button to SLEEP ON/OFF select , clock display 1 will flash. TEMPERATURE MODE FAN SPEED Press “HOUR” button to Press “MINUTE” button change the hour display, AUH FAN SWEEP to change the minute each press of HOUR TIME display, (the method as TIMER button will increase or step 2). The clock 2 decrease the time display HOUR MINUTE display will flash for 10 by 1 hour; hour display 3 seconds after setting, the will be changed
Краткое содержание страницы № 11
Off Timer SET TEMP Set the clock time as Clock Setting, SLEEP ON/OFF Press “TIME” button to 1 select OFF, clock display will flash. TEMPERATURE MODE FAN SPEED Press “HOUR” or AU FAN SWEEP “MINUTE” button; set H TIM TIMER the time to turn on the Press “TIMER” 2 air conditioner on E HOUR MINUT button to select 3 timer. At this time if E OFF . user press “MINUTE” RESET button, it will increase or decrease by 10 minutes. Note: 1. When off timer
Краткое содержание страницы № 12
Before Starting This Unit 1) Select a suitable location ,make sure you have easy access to an electrical outlet. 2) Install the Flexible Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig.7 Fig.7a NOTE: Step 2) is required only while using the cooling mode. Fig.7 Fig.7a 3) Plug the unit into the grounded electrical outlet. 4) Make sure the water pump drain hose is correctly installed, as Fig.8 . 5) Press the on/off button to turn on the
Краткое содержание страницы № 13
Power supply: - Insert the plug of the air conditioner into a standard three prong outlet. 2. COOLING OPERATION - Connect the power and press the “ ON/OFF ” button. - Press the “ MODE” button several times until the cooling indicator light comes on. - Press the “ TEMP SETTING” buttons ▲or ▼ to select your desired room temperature. (60-89) - Press the ″FAN SPEED ″ button to choose the fan speed: AutoHighMediumLow. 3. DEHUMIDIFYING OPERATION - Connect the power and press the “ ON/O
Краткое содержание страницы № 14
This is located on the back-side of the AC.) 8. CONTINUOUS DRAINAGE - When you plan to leave this unit unused for a long time or do not want to use the water pump, remove the rubber stopper from the continuous drainage plug and attach a tube or hose for continuous drainage. All the water in the water tank will drain once the continuous drainage plug is removed.(Under this condition, the water pump is not activated.) NOTE: 1. This type of air conditioner’ s waterproof level is IPX0. Do not
Краткое содержание страницы № 15
Fig.10 A) TEMPORARY 1. Attach one end of the duct to the exhaust air outlet of the mobile air conditioner, first fit the left side of the duct on the exhaust air panel, then the right side duct. Push it downwards, be sure to fix thoroughly.(See the fig.10 ) 2. Put the end of duct to a nearby window. Window Kit Installation Your window kit has been designed to fit most standard “Vertical” ,and “horizontal” window applications , However,
Краткое содержание страницы № 16
MAINTENANCE IMPORTANT: 1) BE SURE TO UNPLUG THE UNIT BEFORE CLEANING. 2) DO NOT USE GASOLINE, THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT. 3) DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR USING A HOSE. 4) IF THE POWER CORD IS DAMAGED, IT SHOULD BE REPAIRED BY MANUFACTURE OR ITS AGENCY . Fig.12 1. AIR FILTER - Clean the air filter at least once every two weeks to prevent inferior fan operation from dust build-up. - Removal Pull out the filter cover and re
Краткое содержание страницы № 17
SUGGESTED PROBLEM POSSIBLE CAUSES REMEDIES - Water full indicator blinks, Dump the water in the water 1. UNIT DOES NOT START water tank is full. tank. WHEN PRESSING ON/OFF - Room temperature is higher Reset the temperature. BUTTON than the set temperature. (Heating mode) - Room temperature is lower Reset the temperature. than the set temperature. (Cooling mode). - LCDI plug was tripped. Press the reset button on the LCDI plug. Press On/Off button on the air conditioner. - The w
Краткое содержание страницы № 18
18