Краткое содержание страницы № 1
MINIDISC RECORDER
ENREGISTREUR MINIDISC
XM-G6
SAMPLING RATE CONVERTER
MINIDISC RECORDER XM-G6
REC PAUSE
REC
INSTRUCTIONS For Customer Use:
Enter below the Model No. and Serial
MANUEL D'INSTRUCTIONS No. which are located either on the rear,
bottom or side of the cabinet. Retain this
information for future reference.
Model No.
Serial No.
LVT0378-001A
[J]
XM-G6[J].cover 1 99.11.26, 20:05
Краткое содержание страницы № 2
Warnings, Cautions and Others Mises en garde, précautions et indications diverses CAUTION WARNING: TO REDUCE THE RISK OF FIRE RISK OF ELECTRIC SHOCK OR ELECTRIC SHOCK, DO NOT EXPOSE DO NOT OPEN THIS APPLIANCE TO RAIN OR MOISTURE. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK. DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. CAUTION The lightning flash with arrowhead symbol,
Краткое содержание страницы № 3
IMPORTANT FOR LASER PRODUCTS/ IMPORTANT POUR LES PRODUITS LASER 1 CLASSIFICATION LABEL, PLACED ON REAR 2 WARNING LABEL, PLACED INSIDE THE UNIT ENCLOSURE 1 ETIQUETTE DE CLASSIFICATION, PLACÉE A 2 ETIQUETTE D'AVERTISSEMENT PLACÉE À L'ARRIÈRE DU COFFRET L'INTERIEUR DE L'APPAREIL DANGER: Invisible laser VARNING: Osynlig laser- radiation when open and strålning när denna del är interlock failed or defeated. öppnad och spärren är CLASS 1 AVOID DIRECT EXPOSURE urkopplad. Betrakta ej LASER
Краткое содержание страницы № 4
QUALITY SERVICE HOW TO LOCATE YOUR JVC SERVICE CENTER TOLL FREE : 1-800-537-5722 http://www.jvcservice.com Dear customer: In order to receive the most satisfaction from your purchase, read the instruction booklet before operating the unit. In the event that repair is necessary, or for the address nearest your location, please refer to the factory service center list below or within the Continental United States, Call 1-800-537-5722 for your authorized servicer. Remember to retain your Bill of Sa
Краткое содержание страницы № 5
LIMITED WARRANTY AUDIO-1 JVC COMPANY OF AMERICA warrants this product and all parts thereof, except as set forth below ONLY TO THE ORIGINAL PURCHASER AT RETAIL to be FREE FROM DEFECTIVE MATERIAL AND WORKMANSHIP from the date of original retail purchase for the period as shown below. (“The Warranty Period.”) PARTS LABOR 1YR 1YR THIS LIMITED WARRANTY IS VALID ONLY IN THE FIFTY(50) UNITED STATES, THE DISTRICT OF COLUMBIA AND IN COMMONWEALTH OF PUERTO RICO. WHAT WE WILL DO: If this product is found
Краткое содержание страницы № 6
Introduction We would like to thank you for purchasing one of our JVC products. Before operating this unit, read this manual carefully and thoroughly to obtain the best possible performance from your unit, and retain this manual for future reference. Welcome to XM-G6 Precautions XM-G6 is MiniDisc Recorder exclusively designed for FS- Installation G6 compact component system. Although you cannot • Install in a place which is level, dry and neither too hot operate this MD recorder without FS-G6, t
Краткое содержание страницы № 7
Contents Introduction .......................................................... 1 Handling MDs ..................................................... 27 Welcome to XM-G6 ............................................................. 1 MD Handling Precautions .................................................. 27 Precautions ........................................................................... 1 Additional Information ...................................... 28 Contents ........................
Краткое содержание страницы № 8
Location of the Buttons and Controls Become familiar with the buttons and controls on the unit. XM-G6 MiniDisc Recorder 1 5 SAMPLING RATE CONVERTER 2 6 REC PAUSE 3 7 REC 4 AX-UXG6 Stereo Amplifier (belongs to FS-G6) OPEN/CLOSE POWER STANDBY/ON 1 COMP ACT COMPONENT SYSTEM FS-G6 4 5 2 6 FM/AM AUX MULTI JOG VOLUME MOS - FET 3 7 ( ) Buttons behind the Sliding Panel When pressing OPEN/CLOSE button 4 DISPLAY PLAY REC TITLE CLOCK /CHARA. 4 ¢ SET CANCEL ENTER MODE MODE /EDIT /TIMER POWER STANDBY/ON OPE
Краткое содержание страницы № 9
Front Panels Remote Control (belongs to FS-G6) MiniDisc Recorder XM-G6 1 MD IN lamp (7) * MD related operations are mainly assigned to 2 MD loading slot (7) the hollow buttons as illustrated bellow. 3 REC PAUSE button (12) 4 REC indicator (12) 50 (eject) button (8) REMOTE CONTROL RM-SFSG6J 66 (play/pause) button (8) PANEL OPEN/CLOSE DIMMER POWER 77 (stop) button (8) ACTIVE CLOCK/TIMER SLEEP BASS EX. BASS TREBLE FM MODE PLAY MODE REPEAT AUTO PRESET TITTLE/EDIT ENTER DISPLAY /CHARA. CANCEL Ste
Краткое содержание страницы № 10
Getting Started Unpacking When connecting the XM-G6 MD recorder Make sure to turn off FS-G6 and unplug the AC power After unpacking, check to be sure that you have the cord. Leave it until all the connections complete. following items. • Optical digital cable (1) DO NOT place XM-G6 unit or any other • External wire (1) equipment onto AX-UXG6 stereo amplifier unit. Damage or malfunction may result from heat generating portion of AX-UXG6. The number in the parentheses indicates the quantity of the
Краткое содержание страницы № 11
Connecting Another Digital Audio Equipment For digital audio recording onto an MD, XM-G6 unit connected to FS-G6 system has one more optical digital terminal (OPTICAL DIGITAL IN for AUX), prepared for an external digital audio output equipment. When connecting another digital equipment Make sure to turn off FS-G6 system with XM-G6 unit and unplug the AC power cord. Leave it until all the connection completes. XT-UXG6 DIGITAL OUT for XM-G6 DIGITAL IN for XT-UXG6 XM-G6 DIGITAL IN for AUX Protectiv
Краткое содержание страницы № 12
Playing Back an MD OPEN/CLOSE POWER STANDBY/ON OPEN/CLOSE REMOTE CONTROL RM-SFSG6J PANEL PANEL OPEN/CLOSE COMP ACT COMPONENT SYSTEM FS-G6 DIMMER OPEN/CLOSE POWER MULTI JOG ACTIVE BASS EX. CLOCK/TIMER SLEEP Play mode indicators FM/AM AUX MULTI JOG VOLUME MOS - FET BASS TREBLE FM MODE PLAY MODE REPEAT PLAY MODE REPEAT AUTO PRESET TITTLE/EDIT ENTER DISPLAY SET DISPLAY PLAY REC TITLE CLOCK /CHARA. CANCEL SET /CHARA. 4 ¢ CANCEL ENTER MODE MODE /EDIT /TIMER CANCEL UP SET < > UP/DOWN DOWN
4
Краткое содержание страницы № 13
Continued Searching and Skipping Tracks If the MD or each track has a title The disc title and track titles will be shown at the lower portion of the display window (Title longer than While playing back an MD, you can do the following 11 characters scrolls to show the entire title). operations. To search and skip to a particular point in a track DO NOT insert any foreign matters. During playback, press and hold 4 / ¢ button to meet the desired passages in a track: Press and hold ¢ button: 2 Pres
Краткое содержание страницы № 14
Continued Programing the Playing Order of the Tracks • If you try to program a 33rd step “MEMORY FULL” will appear in the display — Program Play window, and your entry is ignored. • The total playback time of programed tracks You can arrange the order in which the tracks play before exceeds 99’59” you start playing. You can program up to 32 tracks. “– – : – –” will appear in the display window. 1 Insert an MD. • If the current playing source is not the MD, press 6 Press 6 (play/pause) button on
Краткое содержание страницы № 15
Playing at Random — Random Play Repeating Tracks — Repeat Play The tracks of the loaded MD will play in no special order You can have the entire disc, the programed tracks, or the (at random) when you select this mode. individual track repeat as many times as you like. 1 Insert an MD. 1 Insert an MD. If the current playing source is not the MD, press 6 If the current playing source is not the MD, press 6 (play/pause) button on the MD recorder, then 7 (stop) (play/pause) button on the MD recorder
Краткое содержание страницы № 16
Recording onto an MD Things to Know Before You Start Recording • It should be noted that it may be unlawful to pre-recorded tapes, records, or discs without the consent of the owner of copy right in the sound or video recording, broadcast or cable program and in any literary, dramatic, or artistic embodied therein. • The sampling frequency rate converter built in the MD recorder allows you to record a digital source if its sampling frequency is 32 kHz, 44.1 kHz, or 48 kHz. If no source equipment
Краткое содержание страницы № 17
Continued OPEN/CLOSE PANEL REMOTE CONTROL RM-SFSG6J POWER STANDBY/ON OPEN/CLOSE PANEL OPEN/CLOSE DIMMER OPEN/CLOSE POWER COMP ACT COMPONENT SYSTEM FS-G6 ACTIVE BASS EX. CLOCK/TIMER SLEEP FM/AM AUX BASS TREBLE FM MODE MULTI JOG MOS - FET VOLUME FM/AM AUX PLAY MODE REPEAT AUTO PRESET TITTLE/EDIT ENTER DISPLAY/CHARA. DISPLAY SET /CHARA. CANCEL DISPLAY PLAY REC TITLE CLOCK 4 ¢ SET /CHARA. CANCEL ENTER MODE MODE /EDIT /TIMER CANCEL UP SET < > AUX DOWN
MD 6 MD AUX DISPLAY/CHARA. SET REC MO
Краткое содержание страницы № 18
Continued 5 Press 6 (play/pause) button on the MD recorder Track marking in Long Recording to start recording. Putting track marks manually while recording, you The REC indicator remains lit, and recording starts. can easily identify and edit desired portions of the broadcast program. • To stop recording temporarily, press REC PAUSE To put a track mark, press SET button as required button or 6 (play/pause) button on the MD recorder while recording and you can find out the current track number us
Краткое содержание страницы № 19
Continued Recording a CD — Synchronized Recording Recording a CD This is the easiest way of CD recording. Setting the recording When recording a CD onto an MD, you can record the entire mode, you can start playing back an entire CD and recording CD or the particular tracks manually and using the it onto an MD simultaneously. synchronized recording. 1 Repeat the steps 1 and 2 in previous section. Recording a CD Manually 2 Press REC MODE button behind the sliding panel You can start recording an e
Краткое содержание страницы № 20
Continued • To stop recording temporarily, press REC PAUSE Recording a Tape button or 6 (play/pause) button on the MD recorder or MD 6 (play/pause) button on the remote control. When recording from TD-UXG6 cassette deck, you can • To resume recording, press 6 (play/pause) button select one of the two recording methods — Manual on the MD recorder or MD 6 (play/pause) button Recording (stereo) and Sound Synchronized Recording. on the remote control again. • Manual Recording — Sound is recorded in