Краткое содержание страницы № 1
RP5030 EN (B ver) 15/11/06 10:28 AM Page 2
User manual
Guide de l’utilisateur
Manual de usuario
64M
DIGITAL VOICE RECORDER
ERASE MENU
RP5030
RP5035
It is important to read this instruction book prior to using your new product for the first time.
Nous vous recommandons de lire ce manuel d’instructions avant d’utiliser votre nouveau produit pour la première fois.
Es importante leer este manual antes de usar por vez primera su euipo.
Краткое содержание страницы № 2
RP5030 EN (B ver) 15/11/06 1:44 PM Page 3 FCC Information FCC Information For Your Records This device complies with Part 15 of the FCC In the event that service should be required, EN Rules. Operation is subject to the following you may need both the model number. In two conditions: (1) This device may not cause the space below, record the date and place harmful interference, and (2) this device of purchase: must accept any interference received, Date of Purchase: including interference tha
Краткое содержание страницы № 3
RP5030 EN (B ver) 15/11/06 10:28 AM Page 4 FCC Information Ecology • The unit must only be opened by qualified personnel. Help protect the environment - we EN • Do not expose this appliance to rain or recommend that you dispose of moisture. used batteries by putting them into specially designed receptacles. Precautions for Batteries Maintenance • If you do not use the unit for more than one month, be sure to remove the Clean the unit with a soft cloth, batteries to avoid leakage. or a da
Краткое содержание страницы № 4
RP5030 EN (B ver) 15/11/06 10:28 AM Page 5 Contents FCC Information Recording quality/condition . . . . .10 EN Contents Other Functions . . . . . . . . . . . . . . .11 IntroScan . . . . . . . . . . . . . . . . . . . . . .11 General Controls . . . . . . . . . . . . . . .1 Play one/play all . . . . . . . . . . . . . . . .11 The Display . . . . . . . . . . . . . . . . . . .3 Erasing file/folder . . . . . . . . . . . . .12 Erasing selected file . . . . . . . . . . . . .12 Display messages . . . .
Краткое содержание страницы № 5
RP5030 EN (B ver) 15/11/06 10:28 AM Page 6 General Controls EN Built-in Recording microphone indicator REC: starts / FORWARD: skips and pauses searches forward. 64M DIGITAL VOICE RECORDER recording. Selects/Browses under menu mode. STOP: stops playback/ REVERSE: skips and recording. Turns searches backward. off the unit. Selects/Browses ERASE MENU under menu mode. PLAY: turns the unit on. Starts/ pauses playback. ERASE: Erases file MENU: Folder, record condition, record quality, AVR on/off, p
Краткое содержание страницы № 6
MIC EAR RP5030 EN (B ver) 15/11/06 10:28 AM Page 7 EN External microphone jack VOL UP: Volume up Connects headphones VOL DOWN: Volume down USB jack : keylock on/off 2
Краткое содержание страницы № 7
RP5030 EN (B ver) 15/11/06 10:28 AM Page 8 The Display EN Battery level Folder (A/B/C/D/ ) indicator Key Lock File selected Time/date/ A BC D recorded time MM DD AM Total number of AM/PM PM files in a folder DICT Recording Bookmark FAST ONE CONF BEEP Conditions SLOW ALL REMAIN LP SP HQ AVR Play/record Total Keytone remaining time for recording Playback Automatic mode: Play Voice one/ Recording Play all Recording Qualities 3
Краткое содержание страницы № 8
RP5030 EN (B ver) 15/11/06 10:57 AM Page 9 Display Messages EN Select all (Introductory Play back & Erasing All Files) ALL Appendix (Adding Appendix) APPEND Cut End (Cutting) CUT-E Cut Start (Cutting) CUT-S Delete (Erasing Selected File) DELETE Memory full FULL Month / day entry mode. MM/DD 12 hour time display mode. 12 HOUR 24 hour time display mode. 24 HOUR Time entry mode TIME Insertion (Inserting New Segments) INSERT Introduction (Introductory Playback) INTRO Off (Automatic Voice Recordin
Краткое содержание страницы № 9
RP5030 EN (B ver) 15/11/06 10:28 AM Page 10 Before You Begin Power supply Starting up the unit This unit can be operated by 2 Press PLAY to turn on the unit to EN “AAA” batteries. start playback or recording. Installing Batteries (not Shutting down the unit included) Press STOP to turn off the unit. 1. Slide the battery compartment door to the bottom and lift up the door to open. Keys lock 2. Insert 2 “AAA” batteries with This feature avoids accidental key polarities matching indications. ac
Краткое содержание страницы № 10
RP5030 EN (B ver) 15/11/06 10:28 AM Page 11 Setting the Time 6. Once the date is entered, you can Year/Date/12/24/Time Setting choose between 12/24 hour clock With this function, you can always display by pressing REVERSE EN read on the display the recording date /FORWARD, then press MENU to and time of your recorded messages. confirm. Follow the steps below for time 7. Once the time setting. format is entered, AM the digits in the You can still use this unit for normal hour field will blink
Краткое содержание страницы № 11
RP5030 EN (B ver) 15/11/06 10:28 AM Page 12 Basic Operation Select folder Select file You can select a specific folder (A, B, You can select a specific file for EN playback. C , D or ) for browsing. Default is folder A. 1. Select the folder you need. 2. Press REVERSE or 1. Press MENU in stop A A FORWARD to mode. AM select the file you 2. Folder A, B, C , D or DICT ONE want. If the file you REMAIN SP icon will blink want is in the on display. current folder, you 3. Press REVERSE or can press R
Краткое содержание страницы № 12
RP5030 EN (B ver) 15/11/06 10:28 AM Page 13 Bookmark Creating a bookmark Deleting a bookmark This feature allows you to create an 1. Select folder (A, B, C , D or ) EN interception point in the recorded 2. Select file. message for quick reference. 3. Press ERASE once and DELETE will blink on the screen. 1. During playback, press REC once to 4. Press and hold PLAY for 3 seconds set a bookmark, the bookmark icon to confirm deleting. (or press STOP to cancel erasing file) flashes on the display.
Краткое содержание страницы № 13
RP5030 EN (B ver) 15/11/06 10:28 AM Page 14 Recording Mode 5. Press RECORD to enter AVR mode. Setting Recording Mode 6. During AVR on You can select between two recording, adjust EN recording modes - manual recording the sensitivity of the and AVR (automatic voice recording). microphone by AVR pressing VOL UP 1. Manual Recording and VOL DOWN, SEN with sensitivity 1. In STOP mode, select folder (A, B, value shows on C , D or ). display (e.g. 2. Press RECORD to start recording. AVR increase s
Краткое содержание страницы № 14
RP5030 EN (B ver) 15/11/06 10:28 AM Page 15 Recording Quality / Condition Setting Recording Quality Setting Recording Condition You can select between three You can select between two recording EN recording qualities. Default is SP. conditions. Default is DICT. Definition Definition • CONF (Conference) - in a more • SP (Standard Play) - open area and recording source is Model RP5030 far from the unit. allows about 520 • DICT (Dictation) - in a more SP minutes recording enclosed area and re
Краткое содержание страницы № 15
RP5030 EN (B ver) 15/11/06 10:28 AM Page 16 Other Functions IntroScan Play one / play all This feature allows playback of the You can choose to play a specific file EN beginning 3 seconds of each file in a or all files in a folder. folder. 1. In STOP mode, 1. Select folder (A, B, press MENU button A repeatedly until C , D or ) and MM DD AM ONE ONE appears on file. DICT display. 2. Press REVERSE or SP 2. Press REVERSE or FORWARD until FORWARD to ALL shows on toggle between display A MM DD ONE
Краткое содержание страницы № 16
RP5030 EN (B ver) 15/11/06 10:28 AM Page 17 Erasing File / Folder Erasing selected file Erasing all files in a folder You can delete a file by the following You can delete all files in a specific EN steps: folder by the following steps: 1. Turn on the unit. 1. Select folder (A, B, C , D or ) 2. Select file. 2. Select a folder (A, B, C , D or ). 3. Press ERASE once and DELETE will 3. In Stop mode, press FORWARD blink on the screen. continuously until “ALL” appears 4. Press and hold ERASE for 3
Краткое содержание страницы № 17
RP5030 EN (B ver) 15/11/06 10:28 AM Page 18 Advanced Operation CAUTION Insert • The edit function does not operate You can insert new segments into a EN when battery power is too low or file without erasing previously the Introduction Mode is in used. recorded content. • After editing a message, “WAIT” 1. Select folder. will be displayed. Do not power 2. Select file for inserting new off the device until “WAIT” segment. disappears. 3. Start playback. A 4. Press MENU twice AM Speed to start re
Краткое содержание страницы № 18
RP5030 EN (B ver) 15/11/06 10:28 AM Page 19 Cut Format (Caution! All data inside the memory will be erased) You can erase unwanted parts from EN your recording. You can format the internal memory when needed. (e.g. compatability 1. Select folder. problem, etc.) 2. Select file. The procedures are as follow: 3. Start playback of A the file with the 1. Turn on the unit. AM unwanted part. 2. Press ERASE, “DELETE” will flash ONE 4. Press ERASE to SP on the display. mark the start of 3. Press and h
Краткое содержание страницы № 19
RP5030 EN (B ver) 15/11/06 10:28 AM Page 20 Connecting to the Computer Install the USB Driver (Windows 98SE Only) EN Tip: For Windows 98SE system, you need • Data transfer is possible even if to install a USB driver before your no batteries are installed in the computer can recognize your player. unit. • On some operating system, a 1. Download the driver for your message warning about "Removing a USB device without model from the following links: stopping it…" might appear, you Model RP5030
Краткое содержание страницы № 20
RP5030 EN (B ver) 15/11/06 10:28 AM Page 21 Using your unit as a file storage Transfer Files via Windows device Explorer (Drag and Drop) EN The unit can function as a detachable Your player is associated with a drive data storage. You can take along letter. From Windows Explorer, your favorite images and documents highlight all the files/folders you wherever you go. Simple cut-and- want to transfer to your Player and paste or drag-and-drop files to or drag them to the folder named from it via