Краткое содержание страницы № 1
IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303
Telephone (800) 238–3600 Facsimile (800) 535–4231
Operator’s Manual
ICE/BEVERAGE DISPENSER
Model: Enduro 200/250
IMPORTANT:
TO THE INSTALLER.
It is the responsibility of
the Installer to ensure that
the water supply to the
dispensing equipment is
provided with protection
against backflow by an air
gap as defined in
ANSI/ASME A112.1.2-1979;
or an approved vacuum
breaker or other such
method as prove
Краткое содержание страницы № 2
TABLE OF CONTENTS Page MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 DAILY (OR AS REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 WEEKLY (OR AS REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 MONTHLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 3
MAINTENANCE The following dispenser maintenance should be performed at the intervals indicated: DAILY (or as required) Remove foreign material from vending area drip tray to prevent drain blockage. WEEKLY (or as required) Clean vending area. Check for proper water drainage from the vending area drip tray. MONTHLY Clean and sanitize the hopper interior and beverage system if applicable (see CLEANING INSTRUCTIONS). START-UP & OPERATING INSTRUCTIONS Fill the hopper with ice. Dispense several large
Краткое содержание страницы № 4
DISPENSER 1. CLEANING EXTERIOR SURFACES Important: Perform the following daily. A. Remove the cup rest from drip tray. B. Wash the drip tray with soap solution. Rinse with clean water and allow solution to run down the drain. C. Wash cup rest with soap solution and rinse in clean water. Install the cup rest into the drip tray. D. Clean all exterior surfaces with soap solution and rinse in clean water. 2. COLD PLATE INSPECTION BEFORE CLEANING A. Remove splash panel. B. Remove the plastic cold p
Краткое содержание страницы № 5
BEVERAGE SYSTEM (IF APPLICABLE) CLEANING WARNING: Disconnect Power Before Cleaning! Do not use metal scrapers, sharp objects or abrasives on the ice storage hopper, top cover and the agitator disk, as damage may result. Do not use solvents or other cleaning agents, as they may attack the plastic material. Soap solution - Use a mixture of mild detergent and warm 100 degrees F potable water. Sanitizing solution - Use 1/2 ounce of household bleach in 1 gallon of potable water. Preparing the sani
Краткое содержание страницы № 6
11. For post-mix valves, remove the nozzle and syrup diffuser and clean them in a mild soap solution. Rinse with clean water, then reinstall the nozzle and syrup diffuser on the valve. 12. For pre-mix valves, disconnect all product tubes from the tank of sanitizing solution and then open the valves to allow the pressure to be relieved. Remove the valves from the dispenser, disassemble and wash thoroughly in a mild soap solution. 13. Rinse the parts in clean water, reassemble the valve and reco
Краткое содержание страницы № 7
WARNING: Disconnect Power Before Cleaning ! Soap solution – Use a mixture of mild detergent and warm (100F) potable water. Sanitizing solution – Use ½ ounce of household bleach in 1 gallon of potable water. Preparing the sanitizing solution to this ratio, the required solution of 200 PPM will be obtained. Cleaning tank – Fill clean, empty tank with a mixture of mild detergent and five (5) gallons of warm potable water (120F). Sanitize Flavor syrup lines, B–I–B System 1. Remove all the quick
Краткое содержание страницы № 8
TROUBLESHOOTING IMPORTANT: Only qualified personnel should service internal components or electrical wiring. WARNING: If repairs are to be made to a product system, remove quick disconnects from the applicable product tank, then relieve the system pressure before proceeding. If repairs are to be made to the CO system, stop dispensing, shut off the CO supply, then relieve the 2 2 system pressure before proceeding. If repairs are to be made to the refrigeration system, make sure electrical powe
Краткое содержание страницы № 9
Trouble Probable Cause BEVERAGE NOT SWEET ENOUGH. A. Empty syrup tank. B. Faucet brix requires adjusting. BEVERAGES NOT COLD (UNITS WITH BUILT–IN A. Unit standing with no ice in hopper – no ice in COLD PLATE). cold plate cabinet. FLAVOR SYRUPS DO NOT DISPENSE A. No 24 volt power to PC board. B. No CO2 pressure. C. Empty syrup tank. D. Kinked tubing. E. Clogged inner nozzle. F. Defective PC board. G. Defective harness from keypad. H. Defective Flow control. I. Defective solenoid harness. J. Defec
Краткое содержание страницы № 10
WARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship under normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or Wilshire product, in your country, please write, fax or telephone the IMI Cornelius office nearest you. Please provide the equipment model number, serial number and the date of purchase. IMI Cornelius Offices AUSTRALIA P.O. 210, RIVERWOOD, NSW 2210, AUSTRALIA (61) 2 533 3122 F
Краткое содержание страницы № 11
IMI CORNELIUS INC. Corporate Headquarters: One Cornelius Place Anoka, Minnesota 55303-6234 (763) 421-6120 (800) 238-3600