Краткое содержание страницы № 1
AX Series
Security and Communication System
Architectural and Engineering
Specifications
Aiphone AX Series 13710 (28 13 00) - 1
Краткое содержание страницы № 2
Aiphone AX Series 13710 (28 13 00) - 2
Краткое содержание страницы № 3
Aiphone Corporation February 2007 1700 130th Avenue NE Bellevue, Washington 98005 Toll Free (800) 692-0200 Phone (425) 455-0510 Fax (425) 455-0071 Website www.aiphone.com E-mail info@aiphone.com Product Guide Specification Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat, and PageFormat, as described in The Project Resource Manual—CSI Manual of
Краткое содержание страницы № 4
Specifier Notes: List standards referenced in this section, complete with designations and titles. This article does not require compliance with standards, but is merely a listing of those used. A. ISO 9001:2000 – Quality Management Systems – Requirements. B. TIA/EIA 568 – Commercial Building Telecommunications Cabling Standard. 1.4 SYSTEM DESCRIPTION Specifier Notes: Edit the system description as required for the project. Consult Aiphone Corporation for more information. A
Краткое содержание страницы № 5
2. Press door station CALL button. 3. Calling tone rings on master station (for normal call, intermittent tremolo sound; for priority call, rapid intermittent tremolo sound) and selector button LED for individual door station flashes (double-flash for priority call). If door station has camera, video from door station shall be displayed on master station monitor. Call tone continues to ring until answered or is timed out (based on setting). You can stop calling tone by pressing OFF butto
Краткое содержание страницы № 6
2. You can communicate with door station from telephone. 3. You can end communication at telephone. Communication also ends automatically when set talk time limit is reached. About 10 seconds before end of call, you will hear alarm sound on telephone. 4. Maximum duration for CO line call is 300 seconds, even if call timer is set to “Infinite”. 5. Using this function requires Viking Electronics, Inc. “K-1900-5 Hot-Line Pulse Dialer”. 6. If there are multiple calls, call from door station
Краткое содержание страницы № 7
I. Monitor: 1. If you press individual door station selector button, you can hear audio and if that door station has a camera, you can see image. 2. Press OFF button to end. Call also ends automatically when set communication end time is reached. 3. While door station is communicating with or monitored by a master station, you cannot monitor that door station from another master station. 4. If you press TALK button while monitoring, hands-free communication mode starts with that door st
Краткое содержание страницы № 8
d. Master station to master station communication. e. Normal All Call. f. Monitor. g. Scan monitor. 1.5 SUBMITTALS A. Comply with Section 01330 (01 33 00) – Submittal Procedures. B. Product Data: Submit manufacturer’s product data, including installation instructions. C. Shop Drawings: Submit the following: 1. Wiring Diagrams: Indicate wiring for each item of equipment and interconnections between items of equipment. 2. Include manufacturer’s names, model numbers, ratings, p
Краткое содержание страницы № 9
A. Integrated Security and Communication System: Aiphone “AX Series”. 1. Power Source: a. 24 V DC, 2 A. b. Two PS-2420UL (110 V AC) per video system. One PS-2420UL (110 V AC) per audio system. 2. Door Station Calling: a. Tremolo call tone programmable from 10 to 600 seconds or infinite. b. LCD monitor remains on for duration of call-in and communication up to a maximum of 10 minutes. 3. Master Station Calling: Select station to call, pre-tone sounds, then speak hands-free or push-
Краткое содержание страницы № 10
d. Video Output Trigger: 1) Open collector output. 2) 24 V DC, 30 mA. 3) Two RJ-45. Specifier Notes: Include the following when specifying central exchange unit models AX-084C or AX- 248C. e. Master and door stations homerun to CEU for connection and programming. f. RJ-45 Input Jacks: Station connection, add-on CEU connection, and CO line output. g. Quick Release: Dry contact terminals for door release functions and power supply connection. h. RS-232 Connection: 1) Input: Progr
Краткое содержание страницы № 11
3. Add-On Exchange Unit: Model AX-320C. a. Connect: Maximum of 32 door stations. b. Current Consumption: 1) Video: 200 mA maximum. 2) Audio: 180 mA maximum. c. Power switch. d. Add-on unit ID setting switch. e. Power/Communications Error Display LED: 1) Off: Power off. 2) Lit: Power on. 3) Flashing: Error in device or wiring. f. Ports: 1) Door station ports. 2) Add-on exchange unit ports. 3) Door release relay ports. 4) Power supply ports. C. Master Stations: Specifie
Краткое содержание страницы № 12
l. RJ-45 jack for connection to CEU. m. Connector for add-on selector on master station. n. Door call-in indicator. o. Hands-free or push-to-talk communication. p. All Call to master stations. q. Scan monitoring. r. Selective door release. s. Privacy and mute functions. t. Wall or desk mount. Metal bracket included for wall mounting. u. Multi-Pin Connector: 1) Video output from master station. 2) External signaling of call tones (through IER-2 or activation of TAR-3). 3) Footswitch
Краткое содержание страницы № 13
d. Camera. e. Camera Protection: Clear Lexan lens cover. f. RJ-45 jack. g. Speaker. h. Microphone. i. Directory card. j. White Illumination LEDs: Automatically turn on in low-light conditions. k. CAT-5e homerun wired to CEU. l. Operating Temperature: 14 degrees F to 140 degrees F (minus 10 degrees C to 60 degrees C). m. Vandal resistant. 3. Fixed Color Video Door Station: Model AX-DVF. a. Faceplate: Stainless steel. b. Flush mount. c. Call Button: Metal. d. Camera. e. Camer
Краткое содержание страницы № 14
f. Camera Protection: Clear Lexan lens cover. g. RJ-45 jack. h. Speaker. i. Microphone. j. Directory card. k. White Illumination LEDs: Automatically turn on in low-light conditions. l. CAT-5e homerun wired to CEU. m. Operating Temperature: 14 degrees F to 140 degrees F (minus 10 degrees C to 60 degrees C). n. Vandal resistant. E. Compatible Door Stations and Accessories: Specifier Notes: Specify required compatible door stations and accessories. 1. Audio Door Station: Mode
Краткое содержание страницы № 15
Specifier Notes: Specify flush or surface mount. b. [Flush mount in standard 2-gang box] [Surface mount by adding SBX-2G]. 7. CCTV Camera Input Module: Model AXW-AZ. a. Converts standard CCTV camera’s signal to CAT-5e connection, providing signal compatible with AX system. b. Video Output: Continual viewing and/or recording via composite pass-through. c. Relay output to trigger external device. d. Input for audio door station (IE/IF series). e. Sensor input (N/C) to activate call-i
Краткое содержание страницы № 16
B. Notify Architect of conditions that would adversely affect installation or subsequent use. C. Do not begin installation until unacceptable conditions are corrected. 3.2 INSTALLATION A. Install integrated security and communication system in accordance with manufacturer’s instructions at locations indicated on the Drawings. B. Mount equipment plumb, level, square, and secure. C. CAT-5e Cables: 1. Run cables from and homerun to one central location where CEU will be installed.
Краткое содержание страницы № 17
A. Adjust integrated security and communication system for proper operation in accordance with manufacturer’s instructions. 3.4 DEMONSTRATION AND TRAINING A. Demonstration: 1. Demonstrate that integrated security and communication system functions properly. 2. Perform demonstration at final system inspection by qualified representative of manufacturer. B. Instruction and Training: 1. Provide instruction and training of Owner’s personnel as required for operation of integrated se