LOCATIONS Corporate Headquarters North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO 90 Coles Road Tel: 856-228-8100 Blackwood, NJ 08012-4683 Fax: 856-228-6673 Email: info@metrologic.com Internet: www.metrologic.com European Headquarters Germany, Metrologic Instruments GmbH Tel: +49 89 89019 0 Middle East and Africa Dornierstrasse 2 Fax: +49 89 89019 200 82178 Puchheim b. Email: info@europe.metrologic.com Munich, Germany Germany Email: info@de.metrologic.com Spain Met
Краткое содержание страницы № 4
TABLE OF CONTENTS Introduction........................................................................................................... 1 Scanner and Accessories..................................................................................... 2 Scanner Connections to the Host......................................................................... 3 Configuration of the Scanner to the Host System................................................. 4 Cloning Feature............................
Краткое содержание страницы № 5
INTRODUCTION Metrologic's MS860 and MS863 laser bar code Scanners are high-speed, aggressive in-counter scanners. Both models have compact, durable housings for use with applications where counter top space is limited. The MS860 and MS863 autodiscriminate all standard bar codes. Each model © includes a code-correcting feature (MECCA ) that enables the scanner to decode damaged or truncated codes on the first pass. Both models can be programmed ® by using the bar code menus from the ScanSelect
Краткое содержание страницы № 6
SCANNER AND ACCESSORIES • MS860 or MS863 Laser Bar Code Projection Scanner • Installation and User’s Guide ....................................................MLPN 00-02202 ® • ScanSelect Scanner Programming Guide ...............................MLPN 00-02186 • Volume Control Card .................................................................MLPN 00-02346 • Installation Plate for MS860 models only ...................................MLPN 45-45471 Optional Accessories • Power Supply ............
Краткое содержание страницы № 7
SCANNER CONNECTIONS TO THE HOST To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. 1. Turn off the host system. 2. Connect the 25-pin D-type connector on the scanner’s head cable to the communication cable. 3. Connect the other end of the communication cable to the host device. 4. If the scanner will not receive power from a transformer, skip to Step 5. If the scanner will receive power from an external power source, check the AC input
Краткое содержание страницы № 8
CONFIGURATION OF THE SCANNER TO THE HOST SYSTEM The MS860/MS863 is shipped from the factory programmed to a set of default conditions noted in the Default Settings section of this guide and in the ® ScanSelect Scanner Programming Guide provided. The default settings in the ScanSelect guide have an asterisk that appears before the brief definition next to the bar code. Since each host system is unique, the scanner will need to be configured to ® match the specific host system’s requirements. If
Краткое содержание страницы № 9
CLONING FEATURE The cloning feature is used to program several scanners with the same settings. To clone a scanner: 1. Turn OFF the power to both scanners by unplugging the transformers. 2. Connect the cloning cable (MLPN 51-51544) between the two scanners. 3. Turn ON the power to both scanners by plugging in the transformers. 4. When each scanner is ready, scan the cloning bar code with the scanner that has the settings that need to be transferred to the other scanner. CLONING 0 12345 77777 6
Краткое содержание страницы № 10
VERSION 11 IBM 46XX SCANNER Output Format: IBM RS-485 serial input/output for the 4680 and 4690 (46XX) point-of-sale terminals The Version 11 46XX interface can be used in several different ways. Both the 46XX terminal and the scanner must be configured to match each other. Warning: Power to the scanner and 46XX terminal should be turned off before making physical connection. The 4680 and 4690 series terminals have different types of physical ports for connecting bar code scanners. Scanner port
Краткое содержание страницы № 11
CONFIGURING THE MS860-11/MS863-11 SCANNER Located in the Version 11 scanner are two computer boards. One computer board is for decoding and the other for 46XX IO processing. The decode board is configured using ScanSet or ScanSelect while the IO board is configured with an internal DIP Switch bank. For UPC/EAN scanning, the decode board should be set as follows: Enable IBM 4680 Communication Enable UPC/EAN Beep after Transmit Enable Communication Timeouts Transmit UPC-A Check Digit Transmit U
Краткое содержание страницы № 12
CONFIGURING THE IBM 46XX The 4683 and 4693 terminals are configured on the store controller. The 4684 and 4694 terminals are typically configured on the individual terminals. Follow the appropriate guide for your type of equipment. IBM 4683 and 4693 Terminals Driven by a 46XX Store Controller Running 4680.OS or 4690.OS Access the terminal configuration menu on the store controller. If not already selected, select an IBM 1520 laser hand scanner (4680.OS Port 5B), an IBM 4500 hand-held bar code
Краткое содержание страницы № 13
VERSION 17 KEYBOARD WEDGE SCANNER The MS860/MS863 scanner (version 17) provides keyboard emulation by converting the scanned bar code data to the PC keyboard scan code equivalent. The following are the supported keyboard and country types: PC Type • AT (includes IBM PS/2 and compatible models 50, 55, 60, 80) • XT • PS/2 (includes IBM PC and compatible models 30, 70, 8556) Keyboard Country Type • USA • Germany • France • Spain • Italy • Belguim • United Kingdom • Swiss With the appropriate commun
Краткое содержание страницы № 14
CONNECTION OF A MS860-17 SCANNER TO A PC 1. If the PC is on, exit your application and turn the PC off. 2. Disconnect the keyboard from the PC. Plug the Keyboard Wedge cable to the PC and the keyboard. Use the adapter cable if necessary. 3. Connect the 25-pin D-type connector on the scanner’s head cable to the Keyboard Wedge cable. 4. Check the AC input requirements of the transformer to make sure the voltage matches the AC outlet. A socket outlet should installed near the equipment and be e
Краткое содержание страницы № 15
OPTIONAL IN-COUNTER MOUNTING OPTIONS FOR THE MS860 Metrologic has designed three plates to accommodate in-counter installation of the MS860. Included automatically with the purchase of the MS860 is Metrologic part #45-45471, Installation Plate. The universal and replacement plates are available for an additional charge. Contact the distributor, dealer or Metrologic customer service representative to order one of these plates. Metrologic Part Number mlpn 45-45471, Installation Plate: This plat
Краткое содержание страницы № 16
VERTICAL STAND KIT Vertical Stand Kit, MLPN 45-45472 includes: a. Vertical Stand [ MLPN 45-45472 ] Qty. 1 b. #6-32 x 3/8” Phillips Head Screw [ MLPN 18-18317 ] Qty. 2 c. #8 x 1.00” Round Head Wood Screw [ MLPN 18-18057 ] Qty. 3 Installation Orientation Note: The arrow on the top of the scanner indicates the direction that items must be presented to the scanner. 1. Drill four #39 pilot holes into the counter top (See Figure 2). 2. Screw the stand to the counter top with the four #8 wood screws
Краткое содержание страницы № 17
SCANNER PARTS Touch Plate When a specified time has elapsed without any scanning, the unit will enter a “standby” mode. Touching the touch plate arrow on the top cover will reactivate the scanner. Red LED When the red LED flashes ON, the scanner has read a bar code successfully. When the red light turns OFF, communication to the host is complete. Green LED When the green LED is ON, this indicates the unit is receiving power and the laser is ON. Output Window This aperture emits laser lig
Краткое содержание страницы № 18
The MS860 TOUCH PLATE The MS860 will enter “standby” when it remains dormant for a time. When the scanner’s computer is on “standby," touching the touch plate will “wake up” the scanner and activate the laser. When the green LED comes on, the scanner is powering up for full operation. After approximately three seconds, the scanner will be ready to operate. The default touch plate timeout is ten minutes. However, this can be changed through ScanSet or by scanning a bar code in Section C of th
Краткое содержание страницы № 19
VISUAL INDICATORS There is a red and green LED at the top of the scanner. When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the scan and scanner. Steady Green When the laser is on, the green LED is also on. This occurs when the touch plate has been touched. The green LED will remain on until the touch plate timeout elapses or until the scanner turns off. Steady Green; Red Flash When the scanner successfully reads a bar code, the red LED will flash
Краткое содержание страницы № 20
VISUAL INDICATORS Signaux optiques Sur la partie supérieure du scanner se trouvent une diode LED rouge et une diode LED verte. Quand le scanner est sous tension, les diodes rouge et verte clignotantes ou allumées vous informent sur l'état du scanner. Ni la diode rouge, ni la diode verte n'est allumée Il existe deux raisons possibles pour que les diodes ne s'allument pas. Premièrement: si le scanner reçoit de l'énergie sans que les diodes ne s'allument, le scanner est resté sans servir pendant un