Краткое содержание страницы № 1
TAY AWA
ARMED READY
AWAY 1 2 3
STAY 4 5 6
7 8 9
PAGE 0 #
R
FA560
S
Y
OFF
ASS BYP
TEST
MAX
CHIME
CODE
ANT INST
READY
OFF
ON
OFF
Y
S
MAX
TEST
ASS BYP
ANT INST
CODE
CHIME
READY
K5305-5PRV2 10/03 Rev. A
R
FA260
ARMED READY
A 2 3
1
B 4 5 6
C 7 8 9
D 0 #
TAY AWA
Краткое содержание страницы № 2
TO ENTER PROGRAMMING MODE: Local programming requires the use of an alpha keypad connected to the keypad terminals on the control. ✱ ✱ A. POWER UP, then depress [ ] and [#] both at once, within 50 seconds of powering up (if 98 was used to exit program mode, this method must be used to reenter program mode). OR B. Initially, key: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0. DATA FIELD PROGRAMMING PROCEDURES Task Procedure ∗ Go to a Data Field Press [ ] + [Field Number], followed by
Краткое содержание страницы № 3
FA148CP entries shown in dashed boxes, which apply only to the Entries apply to both the FA168CPS and controls, except FA168CPS (partition entries) and are not applicable to the FA148CP . Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults. Field Function Data Entries Programmable Values ✱ ✱ SYSTEM SETUP ( 20– 29) ✱ 4 digits, 0–9 20 INSTALLER CODE | | | [4112] ✱ 0 = no; 1 =
Краткое содержание страницы № 4
NOTE: Entry of a number other than one specified will give unpredictable results. ✱ For fields *43 thru *46: Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F. Enter [ ] as the fourth digit if a 3-digit account number (for 3+1 dialer ✱ reporting format) is used. Enter 0 as the first digit of a 4-digit account number for Nos. 0000-0999. Exit field by pressing if only 3 digits are used. E.g., For Acct. B234, enter: #+11| 2 | 3 | 4 Enter 4 or 10 digits, dependin
Краткое содержание страницы № 5
✱ 65 OPEN REPORT CODE [0,0,0] See box above. Part. 1 Part. 2 Common ✱ 66 ARM AWAY/STAY RPT CODE See box above. [0,0,0,0,0,0] Away Stay Away Stay Away Stay Part. 1 Part. 2 Common ✱ 67 RF XMTR LOW BAT REPORT CODE | [00] See box on previous page. UL: must be enabled if wireless devices are used ✱ 68 CANCEL REPORT CODE | [00] See box on previous page. ✱ ✱ RESTORE REPORT CODES ( 70 – 76) ✱ 7
Краткое содержание страницы № 6
✱ Entry 1:: 0 = disabled, 1-15 = 1 min - 15 min 92 PHONE LINE MONITOR ENABLE [0,0] (#+10 = 10 min; #+11 = 11 min; #+12 = 12 min; 1 2 #+13 = 13 min; #+14 = 14 min; #+15 = 15 min) UL: see Inst. Instructions for requirements : Entry 2 NOTE: Output Device must 0 = Keypad display when line is faulted either be programmed to be 1 = Keypad display plus keypad trouble sound STOPPED in field 80 or ✱ 2 = Same as “1”, plus programmed output device STOPPED by Code + # +
Краткое содержание страницы № 7
MISCELLANEOUS SYSTEM FIELDS (*174-*181) 0 = disable; 1 = Clean Me signal reports; ✱ 174 CLEAN ME REPORTING OPTIONS [0] Note: If Clean Me is enabled, you must enter “3” in (for ESL smoke detectors) field ✱56 programming for zone 1 response time. ✱ 0 = 15 seconds 6 = 2-1/2 min #+11 = 7 min 177 DEVICE DURATION 1, 2 [0] [0] 1 = 30 seconds 7 = 3 min #+12 = 8 min (used in *80 Menu mode-Device Actions 5/6) 1 2 2 = 45 seconds 8 = 4 min #+13 = 10 min 3 = 60 sec
Краткое содержание страницы № 8
Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182-*185. Configurable zone types 92 and 93 (FA168CPS only) can only be programmed using the downloader software. Programming Configurable Zone Type options involves making 10 entries in data field *182 for zone type 90 and field *184 for zone type 91, where each entry represents the sum of the values of the various options shown in the tabl
Краткое содержание страницы № 9
*56 ZONE PROGRAMMING WORKSHEET (FA148CP supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets] Zone Zn Type Part. Report Hardwire Rsp. Time Location Type 1 [09] [1] [EOL] [1] 2 [01] [1] [EOL] [1] 3 [03] [1] [EOL] [1] 4 [03] [1] [EOL] [1] [03] [1] [EOL] [1] 5 [03] [1] [EOL] [1] 6 [03] [1] [EOL] [1] 7 8 [03] [1] [EOL] [1] Zone Zn Type Part. Report Input Type Loop Serial No. Location 9 10 11 12 13 14 15
Краткое содержание страницы № 10
*57 FUNCTION KEY PROGRAMMING Option Function A B C D Comments 01 Paging 02 Time Display 03 Arm AWAY 04 Arm STAY 05 Arm NIGHT-STAY 06 Step Arming 07 Device Activation Device: 08 Comm. Test 09 Macro Key 1 10 Macro Key 2 11 Macro Key 3 12 Macro Key 4 zone 95 zone 99 zone 96 paging 00 Emergency Keys: n/a Personal Emergency n/a Silent Alarm n/a Audible Alarm n/a Fire Emergency Keys:
Краткое содержание страницы № 11
✱ 80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes. Notes: 1. ✱ 2. For Powerline Carrier devices (plcd), field 27 must be programmed with a House Code. 3. Tampers of expansion units cannot be used to operate devices. Output Activation Type a
Краткое содержание страницы № 12
Zone Type Definitions Use this zone type if the zone is not used. Type 00 Zone Not Used • Assign to zones that are used for primary entry and exit. Type 01 • Provides entry delay if the control is armed in the Away or Stay modes. Entry/Exit Burglary #1 • No entry delay is provided when the panel is armed in the Instant mode. • Entry delay #1 is programmable for each partition. • Exit delay begins whenever the control is armed, regardless of the arming mode selected, and is i
Краткое содержание страницы № 13
• Arms the system in Away mode when the zone is activated. Type 21 • Pushbutton units send the user number to the central station when arming or disarming. Arm-Away • User code for button must be assigned. • Disarms the system when the zone is activated. Type 22 • User code for button must be assigned. Disarm • Can be used on a zone when an output relay action is desired, but with no accompanying alarm (e.g., Type 23* lobby door access). No Alarm Response • Usually assigned
Краткое содержание страницы № 14
ALPHA VOCABULARY LIST (For Entering Zone Descriptors) 000 (Word Space) L – 156 REAR – W – 057 DOOR ∗ 059 DOWN 106 LAUNDRY ∗ 157 RECREATION 213 WALL – A – 159 REFRIGERATION 214 WAREHOUSE 060 DOWNSTAIRS 107 LEFT 001 AIR 160 RF 216 WEST 061 DRAWER 108 LEVEL 002 ALARM ∗ 161 RIGHT 217 WINDOW ∗ 062 DRIVEWAY 109 LIBRARY ∗ 004 ALLEY 162 ROOM ∗ 064 DUCT 219 WING 110 LIGHT 005 AMBUSH 163 ROOF 220 WIRELESS – E – 111 LINE 0
Краткое содержание страницы № 15
5800 Series Transmitter Input Loop Identification All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones). WIRELESS INPUT TYPES LOOP 3 LOOP 2 LOOP (REED) LOOP "RF" (Supervised RF) Type send periodic check-in 2 1 (REED) (PRIMARY) LOOP 2 signals, as well as fault, restore and low battery signals. LOOP 1 2 (TERMINALS) (AUX. CENTE
Краткое содержание страницы № 16
_ } _ } _ _ + } + + + 149 Eileen Way, Syosset, NY 11791 www.firstalertpro.com Copyright © 2003 Honeywell International Inc.
K5305-5PRV2 10/03 Rev. A 8-PIN CONNECTOR 4-WIRE SMOKE DETECTOR CONNECTIONS USED FOR 4300/1321X10 4219 24-HR BATTERY STANDBY REQUIRED FOR BATTERY FUSE + 5 WIRED EXPANSION MODULE FIRE INSTALLATIONS. USE 12V, 17.2AH FOR REPLACEMENT, TRANSFORMER (8 ADD'L EOLR WIRED ZONES) RELAY 3A BATTERY FOR 600mA AUX POWER. SEE USE SAME VALUE CO