Краткое содержание страницы № 1
Operation/Reference Guide
™
Metreau Entry Communicators
MET-ECOM Metreau Entry Communicator
MET-ECOM-D Metreau Entry Communicator with Display
Last Revised: 12/04/2008
Voice and Video Communication Systems
Краткое содержание страницы № 2
AMX Limited Warranty and Disclaimer This Limited Warranty and Disclaimer extends only to products purchased directly from AMX or an AMX Authorized Partner which include AMX Dealers, Distributors, VIP’s or other AMX authorized entity. AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase, with the following exceptions: • Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the
Краткое содержание страницы № 3
Table of Contents Table of Contents Metreau Entry Communicators ...........................................................................1 Overview .................................................................................................................. 1 Front Components .......................................................................................................... 2 Rear Components............................................................................................
Краткое содержание страницы № 4
Table of Contents Installing the Metreau Entry Communicator.................................................................. 27 Using Zero Configuration .................................................................................29 Overview ................................................................................................................ 29 Bonjour (Zero-Configuration) Client........................................................................ 29 Connecting In a Network Wi
Краткое содержание страницы № 5
Table of Contents Programming ....................................................................................................51 Overview ................................................................................................................ 51 SEND_COMMANDs................................................................................................ 51 Touch Panel Intercom Commands ................................................................................. 51 RTP, RTCP Vide
Краткое содержание страницы № 6
Table of Contents Setup page.................................................................................................................... 76 Someone At The Door page ......................................................................................... 77 Creating Popup Pages ............................................................................................ 78 Door Answer Call popup page ..................................................................................... 78
Краткое содержание страницы № 7
Metreau Entry Communicators Metreau Entry Communicators Overview The Metreau Entry Communicators (FIG. 1) can be placed at entry points of homes, condos and hotels to provide audio/video communications with anyone at a door or gate - all over IP. Any AMX Modero intercom-enabled touch panel can interface with the Entry Communicator and allow residents to open doors, gates and more. FIG. 1 Metreau Entry Communicators There are two variations within the Metreau Entry Communicator device family
Краткое содержание страницы № 8
Metreau Entry Communicators Front Components The front components of the Metreau Entry Communicators are indicated in FIG. 2: OLED display (MET-ECOM-D only) Video Camera Speaker Dual Color LED Status Bar Pushbutton (Doorbell) Microphone FIG. 2 Metreau Entry Communicators - Front Components 2 Metreau Entry Communicators
Краткое содержание страницы № 9
Metreau Entry Communicators Rear Components The rear components of the Metreau Entry Communicators are indicated in FIG. 3: Camera Viewing Angle Adjustment Mounting Slots (2 on each side) ID/Reset pushbutton STATUS (green LED) Ethernet Connection 2 Multi-Purpose I/Os (5V) 2 Low Voltage Relays (1A Contact) Mounting Clip FIG. 3 Metreau Entry Communicators - Rear Components Product Specifications - MET-ECOM MET-ECOM Specifications Power: • PoE powered – no local Power Supply needed • IEEE 802.3
Краткое содержание страницы № 10
Metreau Entry Communicators MET-ECOM Specifications (Cont.) Microphone: • -40 dB sensitivity, built-in echo cancellation (telephone quality) • Full duplex communication • VoIP Telephony Rear Panel Components: • Camera Viewing Angle Adjustment • Ethernet Port - 10/100 Ethernet with PoE. LEDs show communication activity, connection status, speeds, and mode information: SPD (speed) - Green LED lights On when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps. L/A (link/act
Краткое содержание страницы № 11
Metreau Entry Communicators Product Specifications - MET-ECOM-D MET-ECOM-D Specifications Power: • PoE powered – no local Power Supply needed • IEEE 802.3af Compliant Front Panel Components: • OLED Display • Integrated Color Video Camera • Speaker • Dual Color LED Status Bar: (Yellow/ Red) can be used to provide feedback, to attract attention for action, or as general indicator. • Pushbutton (Doorbell) • Microphone OLED Display: • 4-bit Gray Scale • 1.6” Diagonal Display • 180° Viewing Angle
Краткое содержание страницы № 12
Metreau Entry Communicators MET-ECOM-D Specifications (Cont.) Operating Environment: 32° to 104° F (0° to 40° C) Mounting: The MET-ECOM-D is installed in several ways: • 4 screws for hard surface mounting • 2 expansion clips for pressure mounting • Using the optional Surface Mount Box Colors Available: • Black MET-ECOM-BK (FG2408-01-BK) • White MET-ECOM-WH (FG2408-01-WH) • Polished Brass MET-ECOM-PB (FG2408-01-PB) • Antique Brass MET-ECOM-AB (FG2408-01-AB) • Stainless Steel MET-ECOM-SS (FG2408-0
Краткое содержание страницы № 13
Positioning the Camera Positioning the Camera Overview The camera on the Metreau Entry Communicators provides a symmetrical 42° viewing angle, and by default the camera is centered. The Metreau Entry Communicators feature a Camera Viewing Angle Adjustment slider on the rear panel of the unit that allows you to adjust the viewing angle horizontally from -15° to 15°. FIG. 4 indicates the viewing range of the integrated camera in the Metreau Entry Communicators. mounting surface Camera 42° (rear
Краткое содержание страницы № 14
42° Positioning the Camera Top view when camera is centered at 0° 42° LR Camera Viewing Angle Adjustment slider (default) Camera Top view when camera is facing left at 15° LR Camera Top view when camera is facing right at 15° LR Camera FIG. 5 MET-COM-D Camera: Left and Right Viewing Range 8 Metreau Entry Communicators 42°
Краткое содержание страницы № 15
Wiring and Connections Wiring and Connections Overview To avoid any damage to the electronic component, installation must be performed in an ESD safe environment. The installation section addresses the mounting and wiring of the Metreau Entry Communicators. After you have completed the installation you must consult the Using the Configuration Manager section of the Metreau Entry Communicators Operation/Reference Guide (available online at www.amx.com). Additionally, consider the location of y
Краткое содержание страницы № 16
Wiring and Connections Ethernet 10/100 Base-T RJ-45 Wiring Configuration The table below describes the pinouts, signals, and pairing for the Ethernet 10/100 Base-T connector and cable. The Ethernet cable connection is illustrated in FIG. 7. Ethernet Pinouts and Signals Pin Signals Connections Pairing Color 1 TX + 1 --------- 1 1 --------- 2 White-Orange 2 TX - 2 --------- 2 Orange 3 RX + 3 --------- 3 3 --------- 6 White-Green 4 no connection 4 --------- 4 Blue 5 no connection 5 -----
Краткое содержание страницы № 17
Wiring and Connections Input/Output (I/O) Port: Connections and Wiring The I/O port responds to either switch closures, voltage level (high/low) changes, or it can be used for logic-level outputs. A contact closure between the GND and an I/O port is detected as a Push. When used for voltage inputs, the I/O port detects a low signal (0 - 1.5 VDC) as a Push, and a high signal (3.5 - 5 VDC) as a Release (this IO port uses 5V logic but can handle up to 12V without harm). When used for outputs
Краткое содержание страницы № 18
Wiring and Connections Ferrite Installation (Required) Metreau Entry Communicators comes with a Cat5 Suppression Ferrite that must be clipped around the Ethernet cable, inside the wall box (no tools required). 1. Release the latch to open 2. Insert the Cat5 cable 3. Installation complete. the plastic enclosure. and close the enclosure. FIG. 8 Installing the CAT5 Suppression Ferrite When positioning the Ferrite clip inside the wall box, place the bottom of the clip flat against the back insi
Краткое содержание страницы № 19
Wiring and Connections System Diagram FIG. 10 provides a basic NetLinx system diagram using Metreau Entry Communicators: NetLinx Master MVP-8400i MVP-5200i NXA-ENET24PoE NXA-WAP250G PS-POE-AF NXD-1000Vi NXD-700Vi MET-ECOM-D MET-ECOM FIG. 10 Metreau Entry Communicators - System Diagram System Diagram - Intercom The following system diagram (FIG. 11) illustrates an AMX system using Metreau Entry Communicators with both wired and wireless touch panels: FIG. 11 Intercom System Diagram 13 Metrea
Краткое содержание страницы № 20
Wiring and Connections 14 Metreau Entry Communicators