3507535556
GPS-IC Series
PMX-IC B Series
Automatic
TABLE OF CONTENTS
SECTION PAGE
Chain Drive/Belt Drive
SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
PARTS IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Garage Door Operator
ASSEMBLY
1 OPERATOR ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
1A Channel and Power Head Assembly . . . . . . . . . . .10
System
1B Rail and Power Head Assembly . . . .
Краткое содержание страницы № 2
PRE-INSTALLATION CHECK LIST FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM Things to consider if you are planning to “do-it-yourself.” Whether you are replacing an existing garage door operator or installing an operator in your garage for the first time, there are some pre-installation issues which need to be addressed. They are as follows: 2 The Genie Company recommends that you read and fully understand all information and instructions contained herein before choosing a “Do-It-Yourself ” insta
Краткое содержание страницы № 3
TYPICAL SECTIONAL DOOR INSTALLATION 5 1 2 TYPICAL ADDED SUPPORT HEADER BRACKET BRACKET MOUNTING BOARD 3 BRACES 36” POWER CORD TO 120V GROUNDED OUTLET EXTENSION SPRING OR TORSION SPRING 4 3 6 3 ® SAFE-T-BEAM TYPICAL (TRACKLESS) 1-PIECE DOOR INSTALLATION 7 TYPICAL (TRACK GUIDED) 1-PIECE DOOR INSTALLATION ONE-PIECE DOOR SECTIONAL DOOR
Краткое содержание страницы № 4
SAFETY INFORMATION OPERATOR INSTALLATION OVERVIEW OF IMPORTANT POTENTIAL HAZARDS INSTALLATION Garage doors are large, heavy objects that move with the help of springs INSTRUCTIONS under high tension and electric motors. Since moving objects, springs under tension, and electric motors can cause injuries, your safety and the safety of others depend on you reading the information in this manual. If you have WARNING: 4 WARNING: questions or do not understand the information presented, call your ne
Краткое содержание страницы № 5
PARTS IDENTIFICATION FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM 106 5 125 105 124 remotes 103 104 101 126 100 vary by model NOTE: Accessories vary by model. FASTENERS - Shown full size. See Parts List for description. 69 96 128 1/4”-20 x 3/4” Self-Drilling Screw Insulated Staple Bolt, #10-24 x 1/2” Wall Control Screw 112 91 Pan Head Screw #6 x 1-1/4” Bolt, 5/16”-18 x 1/2” Bolt, 3/8”-16 x 7/8” 127 92 10 Nut, 3/8-16 Pan Head Phillips Screw Phillips Hex Head Screw, No. 10 x 1-1/4” No. 8 x 5/8” 90
Краткое содержание страницы № 6
PARTS IDENTIFICATION FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM 6 19 16 Stealth Power Head 7 12 5 4 17 12 12 3 6 11 15 18 14 12 19 2 21 3 20 26 1 22 23 39 40 13 24 12 12 36 34 38 11 10 35 37 27 25 8 29 9 28 33 26 26 32 31 30 Combined Parts List Item Part Name Item Part Name Item Part Name 1 Lens 21 Rectifier Board Assembly 41 Capacitor 2Front Cover 22 Fuse (F1), UL 42 Capacitor Clamp 3Side Cover (by series/model) 23 Fuse (F2), UL 43 Screw, #10-24 x 1/2”, Slot HH Sf-Tap 4Top Plate Assembly 24 Li
Краткое содержание страницы № 7
PARTS IDENTIFICATION FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM 6 PRO-MAX Power Head 12 5 3 7 12 12 47 7 12 45 11 48 12 46 2 42 4 12 39 10 41 40 25 37 12 52 64 43 49 13 53 33 3 65 1 11 35 9 12 50 28 63 54 55 56 53 52 51 62 57 Item Part Name 58 59 61 Main Drive Worm 60 62 Screw, #8 x 3-1/8” Slot HH, Sf Tap 59 63 Limit Switch Plate 61 64 Screw, #6 x 3/8” Phillips w/Wshr, Sf Tap 59 58 65 Screw, #4 x 5/8”, Slot HH w/Wshr, Sf Tap 8 30 44
Краткое содержание страницы № 8
PARTS IDENTIFICATION FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM Channel 67 8 68 67 69 70 69 71 72 71 71 98 83 71 84 73 85 74 66 86 75 97 71 99 76 89 87 77 71 90 78 83 88 79 80 92 81 94 79 93 82 96 91 89 95 90 Combined Parts List Item Part Name Item Part Name Item Part Name 66 Belt & Bullet Assembly - 7’6” Door 72 Channel - 7’6” Door (128” LG) 85 Chain Bullet (Belt Models Only) Belt Bullet Channel - 8’ Door (146” LG) Belt & Bullet Assembly - 8’ Door Belt Retainer Channel - 10’ Door (170.75” LG)
Краткое содержание страницы № 9
PARTS IDENTIFICATION FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM Rail 9 118 111 81 119 73 80 82 110 76 121 117 79 68 112 116 120 69 89 113 123 122 90 97 115 87 114 86 94 88 79 95 96 91 89 92 93 90 Item Part Name Item Part Name 102 Boom Support Kit (not shown) 125 STB System Source (Red LED) 103 Safety & Maintenance Guide 126 STB Mounting Brackets (2) 104 Emergency Release Tag (Tri-L) 127 Screw, 1-1/4” Phillips HH 105 Entrapment WARNING Label 128 Insulated Staples 106 Wire 110 Rail (L=112.475”) 1
Краткое содержание страницы № 10
...OPERATOR ASSEMBLY FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM 1 Toward Door Toward Power Head OPEN BLUE PARTS BAG Screws for attaching light cover are included in this bag. Please set aside for use later. Carriage 1. Attach emergency release knob cord (Fig. 1-1). • Tie overhand knot in end of cord. 10 • Thread cord through knob so knot is inside knob. • Thread cord through hole in carriage lever. • Tie overhand knot in other end of cord. Emergency Do Not cut cord until after power head is mou
Краткое содержание страницы № 11
5. Fasten rail to power head. • Align mounting holes of sprocket saddle, rail and power head frame. • Insert the two (2) 5/16” x 1/2” hex head screws[112], then two (2) No. 10-24 x 1/2” hex head screws [69]. • Tighten screws. 11 Adjusting NOTE: Inner-slide/bullet should remain at mid-travel Bolt when assembling to power head to provide proper travel when setting limits. 6. Use adjusting bolt to set chain tension (Fig. 1-4) Fig. 1-4 • Chain should sag slightly but not so much that it drags o
Краткое содержание страницы № 12
Краткое содержание страницы № 13
CAUTION Line “V” “B” Header bracket must be fastened to garage framing. Do Not fasten to drywall, particle Header Bracket “A” board, plaster or other such materials. Line “H” 3. Install header bracket (Fig. 2-3) • Place bracket so: 13 – center hole is on line “V.” – all holes are on line “H.” • Mark hole positions “A” and “B.” Vertical Centerline • Drill 5/32” holes at marked positions. of Door • Fasten bracket to header using two (2) 1/4” x 2” Lag Screws [ ] 79 [ ] lag screws 79 . Fig. 2-3 4. A
Краткое содержание страницы № 14
Краткое содержание страницы № 15
... FOR TRACKLESS DOORS 2B Line “V” WARNING See (Vertical centerline of door) TABLE A • Do Not try to remove, repair or adjust springs or anything to which door spring parts are fastened, Door header such as, wood blocks, steel brackets, cables or Top of door 15 other like items. Line “H” Repairs and adjustments must be made by a trained service person using proper tools and instructions. • Handles and other door projections can catch Inside of door clothing. Remove ropes, hooks, hangers,
Краткое содержание страницы № 16
5. Install door braces “V” “V” (See CAUTION below). Top of Door TT op of Door op of Door CAUTION Dessus de la porte Dessus de la porte Doors made of masonite, OR lightweight wood, fiberglass, “V” “V” and metal must be properly 16 braced before mounting [ ] 96 an operator. [ ] 96 [ ] 79 Contact door manufacturer or distributor for [ ] 79 bracing instructions. Fig. 2-12 6. Install door bracket (Fig. 2-12). Header bracket • Contact door manufacturer for proper installation. NOTE: Self-drilling sc
Краткое содержание страницы № 17
OPEN YELLOW PARTS BAG Straight door arm CAUTION [ ] 91 Bolt, 3/8-16 x 7/8” Mounting bracket must be fastened to garage framing. Do Not fasten to drywall, particle board, Curved door arm plaster or other such materials. 17 [ ] 92 3/8-16 nut 9. Mount power head (See Section 2 ALTERNATE MOUNTING METHODS). • Be sure rail assembly and power head are on door center line (line “V”). Fig. 2-16 • Check the illustrations. Decide which mounting method you will use. Materials for mounting are not includ
Краткое содержание страницы № 18
® ... SAFE-T-BEAM INSTALLATION FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM 3 WARNING There should be no electrical power to the ® operator while installing Safe-T-Beam System wires. If you have plugged in the power cord —UNPLUG IT NOW. 18 NOTE: The operator will not close the door ® automatically unless the Safe-T-Beam System is installed. mark 1. Mounting brackets. • Mark both sides of garage door frame or wall 5” FIG. 3-1 Mark door frame. above floor (Fig. 3-1). • Hold bracket against door
Краткое содержание страницы № 19
CAUTION Staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the STB System 2 to stop working. When using the insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly. 3 19 • Make wire attachments at STB’s. – Splitting and stripping wire ends to be FIG. 3-6 FIG. 3-7 FIG. 3-8 (ProMax) connected as shown (Fig. 3-6). Splitting and Attachments Attachments at stripping. at STB. power head. – Loosen terminal screws. – Insert wire u
Краткое содержание страницы № 20
... WALL CONTROL INSTALLATION FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM 4 Power head WARNING White terminals 1 Power cord must be unplugged before attaching Striped Wall W 2 button wires. Be sure wire ends do not touch each other B terminals or other terminals. 3 W1 20 B2 Back view 4 Y3 G4 CAUTION OR MORE • Use of any other wall control will cause the White PUSH OPEN TO SET 1 LIMITS light not to work and could cause door to TMENT Wall BW Striped console operate by surprise. 2 terminals Power