Краткое содержание страницы № 1
Installation Manual
Par t Number 3-9000-765Revision D
March 2013
TM
Daniel 3812 Liquid Ultrasonic Flow Meter
for Direct or Remote Mount Meter Electronics
Краткое содержание страницы № 2
Краткое содержание страницы № 3
Daniel customer service Location Telephone number Fax number North America/Latin America +1.713.467.6000 +1.713.827.4805 Daniel Customer Service +1.713.827.6413 +1.713.827.6312 USA (toll free) +1.888.356.9001 +1.713.827.3380 Asia Pacific (Republic of Singapore) +65.6777.8211 +65.6777.0947.0743 Europe (Stirling Scotland, UK) +44 (0)1786.433400 +44 (0)1786.433401 Middle East Africa (Dubai, UAE) +971 4 8118100 +971 4 8865465 Email • Customer Service: tech.service@emersonprocess.com • Customer Suppo
Краткое содержание страницы № 4
Signal words and symbols Pay special attention to the following signal words, safety alert symbols and statements: Safety alert symbol This is a safety alert symbol. It is used to alert you to potential physical injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Danger indicates a hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates a hazardous situation which, if not avoided, could result in deat
Краткое содержание страницы № 5
Important safety instructions Daniel Measurement and Control, Inc. (Daniel) designs, manufactures and tests products to function within specific conditions. Because these products are sophisticated technical instruments, it is important that the owner and operation personnel strictly adhere both to the information printed on the product and to all instructions provided in this manual prior to installation, operation, and maintenance. Daniel also urges you to integrate this manual into your t
Краткое содержание страницы № 6
Product Operation Personnel: • To prevent personal injury, personnel must follow all instructions of this manual prior to and during operation of the product. • Follow all warnings, cautions, and notices marked on, and supplied with, this product. • Verify that this is the correct instruction manual for your Daniel product. If this is not the correct documentation, contact Daniel at 1-713-827-6314. You may also download the correct manual from: http://www.daniel.com • Read and understand all
Краткое содержание страницы № 7
Notice THE CONTENTS OF THIS PUBLICATION ARE PRESENTED FOR INFORMATIONAL PURPOSES ONLY, AND WHILE EVERY EFFORT HAS BEEN MADE TO ENSURE THEIR ACCURACY, THEY ARE NOT TO BE CONSTRUED AS WARRANTIES OR GUARANTEES, EXPRESSED OR IMPLIED, REGARDING THE PRODUCTS OR SERVICES DESCRIBED HEREIN OR THEIR USE OR APPLICABILITY. ALL SALES ARE GOVERNED BY DANIEL'S TERMS AND CONDITIONS, WHICH ARE AVAILABLE UPON REQUEST. WE RESERVE THE RIGHT TO MODIFY OR IMPROVE THE DESIGNS OR SPECIFICATIONS OF SUCH PRODUCTS A
Краткое содержание страницы № 8
Warranty and Limitations 1. LIMITED WARRANTY: Subject to the limitations contained in Section 2 herein, Daniel Measurement & Control, Inc. ("Daniel") warrants that the licensed firmware embodied in the Goods will execute the programming instructions provided by Daniel, and that the Goods manufactured by Daniel will be free from defects in materials or workmanship under normal use and care and Services will be performed by trained personnel using proper equipment and instrumentation for the p
Краткое содержание страницы № 9
Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Table of Contents 3-9000-765 Rev D March 2013 Contents Daniel customer service ................................................................................... 3 • Signal words and symbols .............................................................................. 4 • Important safety instructions ......................................................................... 5 Section 1: Introduction 1.1 Typical Appli
Краткое содержание страницы № 10
Table of Contents Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual March 2013 3-9000-765 Rev D 3.6 I/O connections ......................................................................................... 55 3.6.1 Frequency/Digital outputs ...........................................................................56 3.6.2 Analog input settings ...................................................................................60 3.6.3 Analog output settings .................
Краткое содержание страницы № 11
Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Installation Manual List of Tables 3-9000-765 Rev D March 2013 List of Tables Table 1-1 Acronyms, abbreviations and definitions ........................................................................... 3 Table 1-2 Meter specifications......................................................................................................... 14 Table 2-1 3812 Ultrasonic Meter shrouds options per ANSI pressure rating ....................
Краткое содержание страницы № 12
List of Tables Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Installation Manual March 2013 3-9000-765 Rev D ii List of Tables
Краткое содержание страницы № 13
Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Installation Manual List of Figures 3-9000-765 Rev D March 2013 List of Figures Figure 1-1 Daniel MeterLink download and registration ................................................................ 6 Figure 1-2 Direct mount electronics assembly with split shroud .................................................... 7 Figure 1-3 Direct mount electronics with latched single band shrouds and remote display............ 8 Figu
Краткое содержание страницы № 14
List of Figures Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Installation Manual March 2013 3-9000-765 Rev D Figure 3-13 Clamped shroud security seals ................................................................................... 67 Figure 3-14 Split shroud security seals ........................................................................................... 68 Figure 3-15 Latched band shroud assembly .........................................................
Краткое содержание страницы № 15
Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev D March 2013 Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meters have direct mount or remote mount electronic options and various configurations that meet a broad range of customer requirements. Each meter comes fully assembled from Daniel Measurement and Control, Inc. and all parts and assemblies are tested prior to shipment. Refer to the following documents for additional deta
Краткое содержание страницы № 16
Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual March 2013 3-9000-765 Rev D 1.2 Features and benefits • Explosion-proof transmitter electronics enclosure with CPU Module, Power Supply, Intrinsic Safety Barrier Module • Intrinsically safe transducer electronics enclosure with the Acquisition Module • Daniel MeterLink (software for Daniel Ultrasonic Flow Meters) ® TM • HART and AMS Suite: Intelligent Device Manager communications for PlantWeb architecture •
Краткое содержание страницы № 17
Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev D March 2013 1.3 Acronyms, abbreviations and definitions Table 1-1 Acronyms, abbreviations and definitions Acronym or abbreviation Definition ° degree (angle) o degrees celsius (temperature unit) C o degrees fahrenheit (temperature unit) F ADC analog-to-digital converter AI analog input AMS® Device Manager Asset Management Software - Device Manager AO analog output ASCII MODBUS A Modbus protocol
Краткое содержание страницы № 18
Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual March 2013 3-9000-765 Rev D Table 1-1 Acronyms, abbreviations and definitions Acronym or abbreviation Definition FODO output that is user configurable as either a frequency or digital output HART® Communication Protocol Highway Addressable Remote Transducer communications protocol hr hour (time unit) Hz Hertz (cycles per second, frequency unit) I/O Input/Output IS Intrinsically Safe K Kelvin (temperature unit)
Краткое содержание страницы № 19
Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev D March 2013 Table 1-1 Acronyms, abbreviations and definitions Acronym or abbreviation Definition PC Personal Computer PFC peripheral field connection (board) P/N part number PS power supply (board) psi pounds per square inch (pressure unit) psia pounds per square inch absolute (pressure unit) psig pounds per square inch gage (pressure unit) R Radius rad radian (angle) RAM Random Access Memory Re
Краткое содержание страницы № 20
Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual March 2013 3-9000-765 Rev D 1.4 Daniel MeterLink software Daniel MeterLink software has robust features for setting communications parameters, calibrating your meter, collecting logs and reports and monitoring the meter health and alarm statuses. Daniel MeterLink may be downloaded at no charge from: http://www2.emersonprocess.com/en-US/brands/daniel/Flow/ultrasonics/Pages/MeterLink.aspx Figure 1-1 Daniel Me