Краткое содержание страницы № 1
MULTI FORMAT LCD MONITOR
DT-V21G11Z
INSTRUCTIONS
For Customer Use:
Enter below the Serial No. which is located on the
rear of the cabinet. Retain this information for future
reference.
Model No. : DT-V21G11Z
Serial No. :
LCT2681-001A
Краткое содержание страницы № 2
Safety Precautions The lightning flash with arrowhead symbol, within an equilateral triangle is CAUTION intended to alert the user to the presence of uninsulated “dangerous voltage” RISK OF ELECTRICAL SHOCK within the product’s enclosure that may DO NOT OPEN be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an To reduce the risk of electric shock. Do CAUTION: equilateral triangle is intended to alert not remove cover (or back).
Краткое содержание страницы № 3
Do not attempt to service this product yourself, as opening or • The AC power supply is controlled by turning on/off the removing covers may expose you to dangerous voltages and POWER switch on the rear panel. If the product is installed in a other hazards. Refer all service to qualified service personnel. place where you cannot easily turn on/off the POWER switch, control the AC power supply by plugging/unplugging the power cord into/from the AC outlet. In this case, install the product as
Краткое содержание страницы № 4
Safety Precautions (cont.) IMPORTANT SAFETY INSTRUCTIONS 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9) Do not defeat the
Краткое содержание страницы № 5
Operating Precautions The LCD panel and backlight have life expectancy. Due to the basic characteristics of the LCD panel, an afterimage or uneven display may occur. It is recommended that you change images occasionally, activate the power saving function, or often turn off the power to reduce the load on the LCD panel. Continuous operations of the LCD panel may accelerate the deterioration. Caution for use of the product for many hours In the case that you use the monitor for many hours, we
Краткое содержание страницы № 6
Installation ● Do not rest your arm on the monitor or lean against the monitor. ● Do not touch the LCD panel when installing the monitor. ● Be sure to install the monitor securely to prevent the monitor from falling over, which may cause damage to the monitor or injury. ● How to set up 1 ● To detach the stand You can tilt the monitor as follows. Lay the monitor on a cloth with the LCD panel facing down to prevent the LCD panel from being damaged. When the monitor is not tilted (0°), the guide
Краткое содержание страницы № 7
● To install the monitor on a shelf or any other suitable surface using screws You can install the monitor on a shelf etc. by changing the position of the bottom plate of the stand to a rearward position. CAUTION ● Lay the monitor on a cloth with the LCD panel facing down to prevent the LCD panel from being damaged. ● When you change the position of the bottom plate of the stand, be sure to install the monitor using screws (not provided). 1 Remove the bottom plate of the stand from the stand bod
Краткое содержание страницы № 8
Connections Rear panel Security slot Attach a security wire to this slot. Note for connections • Before making any connections, turn off all the equipment. • Use a cord whose plugs correctly match the terminals on this monitor and the equipment. • Plugs should be firmly inserted; poor connections could cause noise. • When unplugging a cord, be sure to grasp its plug and pull it out. • DO NOT connect the power cord until all connections are complete. • Refer also to the user manual of each pie
Краткое содержание страницы № 9
Daily Operations Front panel Tally lamp This lamp is controlled by the tally function of the MAKE/TRIGGER terminal. • You can select the color of the tally lamp from “GREEN” or “RED.” (☞ “TALLY SELECT” in “FUNCTION SETTING” on page 18 and “External Control” on page 22) • “NO EFFECT” is displayed when you press a button which is not available for the current input or signal format (the lamp lights even when the function does not actually work). • You cannot use the buttons for the items contr
Краткое содержание страницы № 10
Daily Operations (cont.) 6 MENU button t INPUT SELECT buttons/lamps Activates/deactivates the display of the MAIN MENU Selects an input. (☞ “Menu Operations” on page 13). SDI 1: Input from the E. AUDIO 3G SDI/HD SDI/ SD SDI (IN 1) terminal 7 COLOR OFF button/lamp SDI 2: Input from the E. AUDIO 3G SDI/HD SDI/ Displays only the luminance signal. SD SDI (IN 2) terminal ● This function does not work for RGB input signals. DUAL LINK: Input from the E. AUDIO 3G SDI /HD SDI/ 8 1:1 button/lamp SD SDI (I
Краткое содержание страницы № 11
Audio Channel Selection Select audio channels emitted from the speakers (L/R) and the AUDIO MONITOR OUT(OUT1(L)/OUT2(R)) terminals, when EMBEDDED AUDIO signals come in to the SDI terminal and SDI input is selected. ● You have to choose a group of selectable audio channels before the channel selection (☞ “E.AUDIO GROUP” in “AUDIO SETTING” on page 16). ● The setting is memorized for each input (SDI 1 and SDI 2). 1 Press or button when a menu is not displayed. The screen for audio channel selec
Краткое содержание страницы № 12
Daily Operations (cont.) On the Status Display If you press the INPUT SELECT button (☞ t on page 10) currently lit, the status of the input signal and setting of MUTING are displayed for about 3 seconds. ● Make the setting to display/hide the status in “STATUS DISPLAY” of the “INFORMATION.” (☞ page 21) ● When “STATUS DISPLAY” is set to “AUTO” or “ON,” the status below is also displayed in the following cases: – When you change the input – When the signal condition of the current input changes
Краткое содержание страницы № 13
Setting the menu Menu Operations MAIN MENU SET-UP MENU Item being 1 Display the menu. selected To display the MAIN MENU ➔ Press MENU button. Operation To display the SET-UP MENU guide ➔ Press button while holding button. 2 Press buttons to select an item, then press button. MAIN MENU Ex. When “MARKER” is ● For some items, adjustments will be made by pressing . selected. 3 Press buttons to select an item, then press buttons to make adjustments. 4 Press MENU button to finish the menu
Краткое содержание страницы № 14
Setting the menu (cont.) MAIN MENU PICTURE FUNCTION Setting for the picture quality. Item Content Setting value 1 APERTURE * Activates/deactivates the function at the level set in “APERTURE LEVEL.” OFF, ON 1 APERTURE LEVEL * Simultaneously corrects the frequency characteristics of the RGB colors. 01 – 10 CTI Adjust the clearness of the outlines of the chrominance signal. OFF, NORMAL, HARD LTI Adjust the clearness of the outlines of the luminance signal. OFF, NORMAL, HARD I/P MODE Selects a prop
Краткое содержание страницы № 15
*1*2 MARKER Settings for marker functions. Item Content Setting value 3 1/2 AREA MARKER * Activate/deactivate the area marker and select the style of it. OFF The setting values and features are as follows. LINE HALF OFF : Deactivate the marker. HALF+L LINE : Displays the area with an outline. BLK. HALF : The area outside the specified aspect ratio of the screen is BLK.+L displayed at 50% transparency. HALF+L : The area of the specified aspect ratio of the screen is indicated by an outline, and
Краткое содержание страницы № 16
Setting the menu (cont.) AUDIO SETTING Settings for the audio output balance, EMBEDDED AUDIO signals and level meter. Item Content Setting value BALANCE Adjust the balance between the right and left speakers. L5 – L1, 0, R1 – R5 1 E.AUDIO GROUP * Select the audio channel group of the EMBEDDED AUDIO signals. 1G, 2G, 3G, 4G, The setting values and selectable audio channels of EMBEDDED AUDIO signals are as follows. 1-2G, 1-3G, 1-4G 1G : Channel 1/2/3/4/1+2/3+4/1 – 4 (1G) 2G : Channel 5/6/7/8/5+6/7
Краткое содержание страницы № 17
1 SCOPE SETTING* Configure the settings for the wave form monitor and vector scope. Item Content Setting value GAIN Adjust the input gain level. –10 – +10 2 SIZE * Set the window size. NORMAL, LARGE 2 POSITION * Select the window position. 1 (Lower right), 2 (Lower left) 3 (Upper left), 4 (Upper right) TRANSPARENT Activates/deactivates the function to make the window translucent. ON OFF ON : Translucent OFF : Normal AUTO OFF Set the function to turn off the window automatically 15 minutes after
Краткое содержание страницы № 18
Setting the menu (cont.) SET-UP MENU FUNCTION SETTING Configure the sub menu display, the lighting color of the tally lamp, the size of images, the brightness of the button lamps. Item Content Setting value sub menu POSI. LOWER1 Select the contents and displaying position of “sub menu.” UPPER1 The setting values and features are as follows. LOWER2 LOWER1 : Displays the current setting and adjustment bar at the lower part of the UPPER2 screen. UPPER1 : Displays the current setting and adjustm
Краткое содержание страницы № 19
PICTURE SUB ADJ. Configure the standard level of image adjustment. Item Content Setting value 1 CONTRAST * Adjust the standard level for the contrast adjusted with the CONTRAST knob on the – 20 – +20 front panel. 1 BRIGHT * Adjust the standard level for the brightness adjusted with the BRIGHT knob on the – 20 – +20 front panel. 1 CHROMA * Adjust the standard level for the chroma adjusted with the CHROMA knob on the – 20 – +20 front panel. 1, 2 PHASE * * Adjust the standard level for the phase ad
Краткое содержание страницы № 20
Setting the menu (cont.) REMOTE SETTING (☞ “External Control” on pages 22) Settings for the external control. Item Content Setting value SERIAL TYPE Select the input terminal used for external control by serial RS232C communication. RS485 PARALLEL TYPE Select the external control method for the MAKE/TRIGGER terminal. MAKE, TRIGGER, SET PIN1 Assign the control functions to the pins of the MAKE/TRIGGER terminal. ☞