User’s Manual
■
Important
Please read this User’s Manual carefully to familiarize yourself with safe and effective
usage. Please retain this manual for future reference.
W ichtig
Lesen Sie die dieses Benutzerhandbuch aufmerksam durch, um sich mit der sicheren
und effizienten Bedienung vertraut zu machen. Bewahren Sie dieses Handbuch zum
spateren Nachschlagen auf.
Important
Veuillez lire attentivement ce Manuel d’utilisation afin de vous familiariser avec ce
produit et de
Краткое содержание страницы № 2
For U.S.A. , Canada, etc. (rated 100-120 Vac) Only FCC Declaration of Conformity We, the Responsible Party EIZO Inc. 5710 Warland Drive, Cypress, CA 90630 Phone: (562) 431-5011 declare that the product Trade name: EIZO Model: RadiForce RS110 is in conformity with Part 15 of the FCC Rules. Operation of this product is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference t
Краткое содержание страницы № 3
English Instructions for Use User’s Manual ■ It shall be assured that the final system is in compliance to IEC60601-1-1 requirements.
Краткое содержание страницы № 4
SAFETY SYMBOLS SAFETY SYMBOLS This manual uses the safety symbols below. They denote critical information. Please read them carefully. WARNING Failure to abide by the information in a WARNING may result in serious injury and can be life threatening. CAUTION Failure to abide by the information in a CAUTION may result in moderate injury and/or property or product damage. Indicates a prohibited action. Indicates to ground for safety. • Power supplied equipment can emit electromagnetic waves, tha
Краткое содержание страницы № 5
English TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS ............................................................................................................... 3 PRECAUTIONS .................................................................................................................... 4 Notice for this monitor .................................................................................................................. 8 1. Introduction ....................................
Краткое содержание страницы № 6
PRECAUTIONS PRECAUTIONS IMPORTANT! • This product has been adjusted specifically for use in the region to which it was originally shipped. If operated outside the region to which it was originally shipped, the product may not perform as stated in the specifications. • To ensure personal safety and proper maintenance, please read this section and the caution statements on the unit (refer to the figure below). [Location of the Caution Statements] [Symbols on the unit] Symbol Location This sy
Краткое содержание страницы № 7
English PRECAUTIONS WARNING If the unit begins to emit smoke, smells like something is burning, or makes strange noises, disconnect all power connections immediately and contact your dealer for advice. Attempting to use a malfunctioning unit may result in fire, electric shock, or equipment damage. Do not open the cabinet or modify the unit. Opening the cabinet or modifying the unit may result in fire, electric shock, or burn. Refer all servicing to qualified service personnel. Do not attemp
Краткое содержание страницы № 8
PRECAUTIONS WARNING To disconnect the power cord, grasp the plug firmly and pull. Tugging on the cord may damage and result in fire or electric shock. The equipment must be connected to a grounded main outlet. Failure to do so may result in fire or electric shock. Use the correct voltage. • The unit is designed for use with a specific voltage only. Connection to another voltage than specified in this User’s Manual may cause fire, electric shock, or equipment damage. Power supply: 100-120/200
Краткое содержание страницы № 9
English PRECAUTIONS WARNING Fluorescent backlight lamps contain mercury (the products that have LED backlight lamps contain no mercury), dispose according to local, state or federal laws. Exposure to elemental mercury can result in effects on the nervous system, including tremor, memory loss, and headache. CAUTION Handle with care when carrying the unit. Disconnect the power cord and cables when moving the unit. Moving the unit with the cord attached is dangerous. It may result in injury. C
Краткое содержание страницы № 10
Notice for this monitor Notice for this monitor • This product is intended to be usedin displaying and viewing digitalimages for diagnosis of X-ray orMRI, etc. by trained medicalpractitioners. It does not supportthe display of mammography imagesfor diagnosis. • This product has been adjusted specifically for use in the region to which it was originally shipped. If the product is used outside the region, it may not operate as specified in the specifications. • This product may not be covered
Краткое содержание страницы № 11
English Notice for this monitor Cleaning NOTE • Chemicals such as alcohol and antiseptic solution may cause gloss variation, tarnishing, and fading of the cabinet or panel, and also quality deterioration of the image. • Never use any thinner, benzene, wax, and abrasive cleaner, which may damage the cabinet or panel. Tips • The optional ScreenCleaner is recommended for cleaning the cabinet and panel surface. If necessary, the stains on the cabinet and panel surface can be removed by moistening
Краткое содержание страницы № 12
1. Introduction 1. Introduction Thank you very much for choosing an EIZO Color Monitor. 1-1. Features • Dual inputs compliant (DVI-I and D-Sub mini 15 pin connectors) • DVI (p.41) digital input (TMDS (p.42)) compliant • Horizontal scan frequency Analog: 30 - 82 kHz Digital: 30 - 65 kHz • Vertical scan frequency Analog: 49 - 86 Hz (1280 x 1024: 49 - 76 Hz) Digital: 59 - 61 Hz (VGA text: 69 - 71 Hz) • Frame synchronous mode 57.5 - 62.0 Hz supported • Resolution 1M pixels (Landscape:
Краткое содержание страницы № 13
English 1. Introduction 1-. Controls and Connectors Front Main Power Switch ® ScreenManager main menu CAL Switch menu Control Panel (7) (1) (2) (3) (4) (5) (6) (1) Input Signal Selection Switches input signals for display when two PCs are connected to Button the monitor. (2) Mode Button Displays the CAL Switch menu (p. 23). (3) Auto Adjustment Button Performs the function to adjust the screen automatically. (analog input only) (4) Enter Button Displays the ScreenManager menu, determines an i
Краткое содержание страницы № 14
1. Introduction Rear D-SUB DVI (8) (9) (10) (12) Power connector (13) (11) 3 (8) Stand* Used to adjust the height and angle of the monitor screen. (9) Security lock slot Allows for connection of a security cable. This lock supports Kensington’s MicroSavere security system. (10) Input signal connector D-Sub mini 15 pin Connector (SIGNAL1) (11) Input signal connector DVI-I Connector (SIGNAL2) (12) USB port (Up) Connects the USB cable in order to use the provided software. (13) USB port (Down) Con
Краткое содержание страницы № 15
English 2. Cable Connection . Cable Connection -1. Before Connecting Before connecting your monitor to the PC, change the display screen settings (resolution (p.42) and frequency) in accordance with the charts below. Tips • When your computer and monitor support VESA DDC, the appropriate resolution and the refresh rate are set just by plugging your display into the computer without any manual settings. Analog Input Resolution Mode Frequency Dot Clock 640 x 480 VGA 60 Hz 135 MHz 640 x 480 V
Краткое содержание страницы № 16
2. Cable Connection -. Connecting the Signal Cable NOTE •Be sure that the power switches of both the PC and the monitor are OFF. •Refer to the PC user's manual when connecting the monitor. 1 Plug thesignal cable into the connectoron the rear of the monitor and the other endof the cableinto the video connectoron the PC. After connecting, secure the cable connectors with the attached screw-in fasteners. SIGNAL1 SIGNAL2 D-Sub mini 15 pin DVI-I Connector Connector Power
Краткое содержание страницы № 17
English 2. Cable Connection 3 Thread thepower cord and signal cablethrough the cable holderon the rear of the monitor stand. NOTE •When threading the cables through the cable holder, lead them to the cable entrance side and pinch the projection to open the cable entrance. •It is recommended that some slack be left in the cables to allow for smooth adjustment of the monitor stand and easy rotation between the portrait and landscape positions. Cable holder Connect the other end of
Краткое содержание страницы № 18
2. Cable Connection 6 Turnon the PC’s power. The image will appear. If an image does not appear, refer to “6. Troubleshooting” (p. 34) for additional advice. Refer to “3-3. Screen Adjustment (In case of Analog Input Signal)” (p. 20) and adjust the screen for analog input. If using the monitor in the digital input signal, it displays the image correctly based on its pre-setting data. When finished, turn off the PC and the monitor. Tips •Adjust the brightness of the screen depending on t
Краткое содержание страницы № 19
English 2. Cable Connection -. Connecting Two PCs to the Monitor Two PCs can be connected to the monitor through the Signal 1 and the Signal 2 on the back of the monitor. Selecting the Active Input The Input Signal Selection Button on the control panel can be used to select either Signal 1 or Signal 2 as the active input at any time. Every time the button is pressed, the input changes. When the signal is switched, the active signal type (Signal 1 or 2/ Analog or Digital) appears at the t
Краткое содержание страницы № 20
3. Adjustment and Settings . Adjustment and Settings -1. How to use the ScreenManager Screen adjustments and settings can be performed with the ScreenManager (OSD) and buttons of the monitor. CAL Switch menu ScreenManager menu Control Buttons Auto Adjustment Button Left, Down, Up, Right Mode Button Enter Button Power Button NOTE • The ScreenManager menu and the CAL Switch menu cannot be displayed at the same time. 1 . Enterthe ScreenManager. Press the Enter Button once to display the