Краткое содержание страницы № 1
INSTRUCTION MANUAL
DSR-3716
DSR-3709
Digital Video Recorder
with Multiplexer Function
About this manual
Before installing and using this unit,
please read this manual carefully.
Be sure to keep it handy for later reference.
DSR-3716
DSR-3709
Краткое содержание страницы № 2
English Table of Contents Searching for recorded video . . . . . . . . . . . . . . . . . . . . . . . . . 21 Foreword A Alarm search . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Safety precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 B Alarm thumbnail search. . . . . . . . . . . . . . . . . . . . . . . . . 22 These must be followed for safety reasons . . . . . . . . . . . . 3 b Viewing pre-alarm video . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 3
Table of Contents B Recording area menu description. . . . . . . . . . . . . . . . . 43 E Network settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 b Verifying the capacity of the recording areas. . . . . . . . 43 E-1 Network password modification . . . . . . . . . . . . . . . . . 69 B-1 Changing the normal recording area F RS-485 settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 and the alarm recording area . . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 4
English Safety precautions Declaration of Conformity CAUTION Model Number : DSR-3716/3709 Trade Name : SANYO RISK OF ELECTRIC SHOCK Responsible party : SANYO FISHER COMPANY DO NOT OPEN Address : 21605 Plummer Street, Chatsworth, California 91311 Telephone No. : (818) 998-7322 CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, This device complies with Part 15 of the FCC Rules. DO NOT REMOVE COVER (OR BACK). Operation is subject to the following two conditions: NO USER-SERVICEABLE PARTS INSIDE. (
Краткое содержание страницы № 5
Safety precautions b Do not place in an unstable position. b Do not block the cooling fans or air ducts. This may cause accidents and damage through falling or This unit is equipped with air ducts and cooling fans toppling. in order to assist the ventilation of hot air produced Prohibited by the hard disk drive. Turn the power off and remove the power cable from the Placing covers, placing in a case, or placing inside outlet when the unit has been dropped or the cabinet Prohibited book ca
Краткое содержание страницы № 6
English Safety precautions Follow the points outlined below for proper use b Hard disk This unit is loaded with a hard disk drive. Stored data on this unit may be damaged/lost through hard-disk breakdowns caused by shock/ vibration. Follow the items outlined below when placing, transporting, and operating this unit. Warning Warning G This unit is designed to be positioned horizontally. G Inspecting for abnormalities in the hard disk drive and the Do not position vertically. cooling fan G Do not
Краткое содержание страницы № 7
Safety precautions bBack up battery bMaintaining this unit A lithium battery (fixed) is built into this unit. Supplying Turn the power off and remove the power cable from the power for more than 48 hours after setting the date and time outlet. will allow the internal power source to sustain the set time Wipe away dust using a soft cloth. for 7 days. When the stains are hard to remove... The battery is expected to last for approximately 5 years if the unit is used regularly. Soak the cloth
Краткое содержание страницы № 8
English Main Features Accessories b This digital video recorder (DVR) can record video from Check that you have all the parts shown below. surveillance cameras to its internal hard disk, and it can Quick Guide display the video on a screen split into sixteen, thirteen, Instruction Manual (Digital Video Recorder) nine, six or four fields, both during recording, and Manual for Remote Operation using a Network Connection playback. Power cable/Cord tie The DSR-3709 can split the screen in
Краткое содержание страницы № 9
Names and functions of parts (front panel) DSR-3716 1 2 345 6 7 8 9 FGHIJ 1 Power indicator (POWER) 7 Audio output terminal (AUDIO OUT) On: The power cord at the rear panel of the DVR is inserted in The audio output is the same as that of the rear panel AUDIO the outlet. OUT terminal. Off: The power cord on the rear panel of the DVR is not 8 Video output terminal (VIDEO OUT) inserted in the outlet. The video output is the same as that of the rear panel MAIN Fast blinking: Hard disk error. MON
Краткое содержание страницы № 10
English Names and functions of parts (front panel) K LM N Y X X 12 Open Pull out Front O P Q 2 R Insert 3Fold down 2Lift and (lock) push ST U V W K Menu button and indicator (MENU) T Timer-controlled recording button and indicator (TIMER) On: The menu is displayed. On: Timer-controlled recording or standby. Off: The EXIT/OSD button is pressed. Off: When pressed again (cancel) L Exit/Operation screen display button and indicator (EXIT/ U Alarm buttons ( ALARM ) OSD) When an ALARM button is press
Краткое содержание страницы № 11
CLOCK OUT CLOCK IN NON REC OUT EXIT TIMER IN SERIES OUT SERIES IN ALARM FULL FULL WARNING OUT ALARM RESET ALARM OUT Names and functions of parts (rear panel) Basic connections 3 Video input terminal (VIDEO IN) 1 Clear button (ALL RESET) Press to reset the clocks connected to the digital video Connect SANYO protocol cameras (dome or zoom) or generic cameras to these terminals. recorder to their initial values. ALL Dome camera (sold separately) RESET 2 Video output terminal (VIDEO OUT) To output
Краткое содержание страницы № 12
English CLOCK OUT CLOCK IN NON REC OUT EXIT TIMER IN SERIES OUT SERIES IN ALARM FULL FULL WARNING OUT ALARM RESET ALARM OUT Names and functions of parts (rear panel) Alarm and RS-485 connections 1 Alarm input terminals (ALARM IN) 2 Sensor alarm output terminals Connecting a switch or security sensor etc. to the terminal of the (SENSOR ALARM OUT) DVR allows the detection of the intrusion of outsiders when doors This terminal is used to output the signals listed below etc. are opened and closed
Краткое содержание страницы № 13
CLOCK OUT CLOCK IN CLOCK OUT CLOCK IN CLOCK OUT CLOCK IN NON REC OUT EXIT TIMER IN SERIES OUT SERIES IN ALARM FULL FULL WARNING OUT ALARM RESET ALARM OUT NON REC OUT EXIT TIMER IN SERIES OUT SERIES IN ALARM FULL FULL WARNING OUT ALARM RESET ALARM OUT SERIES IN ALARM FULL FULL WARNING OUT ALARM RESET ALARM OUT Names and functions of parts (rear panel) Control terminals (CONTROL) This DVR can be remotely controlled when a remote-control circuit (R1, R2, C) similar to that shown below is connected
Краткое содержание страницы № 14
English Preparing for use Turn on the power of the DVR Language, clock settings Connect the supplied power cable. Press the MENU button and turn the S-dial clockwise 3 1 1 times. The power indicator turns on, and the monitor displays the "PLEASE SET THE CLOCK !" message. "ENGLISH" starts blinking. The DVR performs playbacks or searches based on the MENU recording date and time. Select the LANGUAGE/CLOCK 1.INITIAL SET -> SET using the INITIAL
Краткое содержание страницы № 15
Preparing for use Operation display The operation display shows information necessary for operation, Changing the position of the operation display such as the date, time and video quality. The operation display can Whenever the EXIT/OSD button is pressed, the position of be hidden. the operation display changes. 12 34567 8 EXIT/OSD 01-01-06 00:00:00 REC REPEAT EN A ALARM 0000 (Hidden) 0 02 02 02 F9 1 Date display 6 Audio recording indicator (P49: 2 AUDIO RECORDING) 01-01-06 (month,
Краткое содержание страницы № 16
English Viewing live video using various multi screens Switching to another full-screen video Enlarging an image in multi-screen mode Press the camera selection button (example 2, 9) of the Press the PLUS button. 1 desired camera. One camera image is displayed enlarged. The video from Camera 2, then the video from Camera 9 are PLUS (Multi-16 mode) displayed. 01 02 03 04 03 04 01 05 06 07 08 07 08 09 10 11 12 12 09 10 11 12 12 02 09 2 9 13 14 15 16 13 14 15 16 (Multi-9 mode) ☞ Refer to P20 for e
Краткое содержание страницы № 17
Viewing live video using various multi screens Automatic screen scrolling Viewing on the monitor connected to the MON2 terminal A Automatic full-screen scrolling Connect a monitor to the MON2 terminal on the rear panel. The Press the SEQUENCE button. display is full-screen only. (P10) The live surveillance video scrolls through the cameras in the While the main monitor is used in split-screen mode, the monitor 2 order of the camera numbers. connected to the MON2 terminal can be used to view
Краткое содержание страницы № 18
English Recording video to the hard disk The internal hard disk is automatically formatted with Normal recording recording area, normal recording, recording conditions, etc. (normal recording area) Before starting recording, verify the recordable duration for normal recording. The formatting can be modified using Video from all cameras connected to the video input terminals of "Recording settings". (P39) the DVR can be recorded with one touch of a button. Press the REC/STOP button during s
Краткое содержание страницы № 19
(Normal recording area) Viewing recorded video This DVR can play video that has already been recorded or Full-screen viewing currently being recorded in the normal recording area (by normal or timer-controlled recording). Press the PLAY/STOP button. 1 Normal recording area Video stored in the normal recording area is played back from the starting point of recording. The " " symbol appears in the operation display area. 10-26-06 09:30:00 REC REPEAT EN A ARCHIV 0001 PLAY/STOP (Hard disk recor
Краткое содержание страницы № 20
English Viewing recorded video Changing the playback speed Viewing still images The corresponding symbol ( , ...) appears in the operation Press the STILL button during playback. display area for each of these operations. The image is paused. The " " symbol appears in the operation Audio will not be played when changing the playback speed. display area. Press the STILL button once again, to return to normal playback. A Fast-forward/Slow playback 10-26-06 09:30:00 REC REPEAT EN A ALARM 0000 ST