Краткое содержание страницы № 1
1HP MINI DUST COLLECTOR
Model 94029
ASSEMBLY AND OPERATING INSTRUCTIONS
®
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our Web site at: http://www.harborfreight.com
TO PREVENT SERIOUS INJURY,
READ AND UNDERSTAND ALL WARNINGS
AND INSTRUCTIONS BEFORE USE.
© ®
Copyright 2005 by Harbor Freight Tools . All rights reserved. No portion of this
manual or any artwork contained herein may be reproduced in any shape or form
without the express written consent of Harbor Freight Tools.
For technical
Краткое содержание страницы № 2
PRODUCT SPECIFICATIONS Item Description Electrical Requirements 120V / 60 Hz / 750 Watts / 1HP Single Phase 3 Prong Power Plug 6’-5” Power Cord Length Power Switch Safety Key Feature Easy Access Carbon Brushes (Qty. 2) Inlet/Outlet Dimensions 4” Diameter Collector Bag Particle Filtration Capacity 35 Micron Collector Bag Holding Capacity 12 Gallons CFM Capacity 914 CFM Sound Rating 107~112 dB @ 3 Feet Overall Dimensions 13-1/4” x 12” x 12” Unit Weight 18-1/2 Pounds SAVE THIS MANUAL You will need
Краткое содержание страницы № 3
presence of flammable liquids, gases, or dust. Power tools create sparks which may ignite flammables. 3. Keep bystanders, children, and visitors away while operating a power tool. Distractions can cause you to lose control. Protect others in the work area from debris such as chips and sparks. Provide barriers or shields as needed. ELECTRICAL SAFETY 4. Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the gr
Краткое содержание страницы № 4
ating a power tool. Do not use a power tool while tired or under the influ- ence of drugs, alcohol, or medication. A moment of inattention while operat- ing power tools may result in serious personal injury. 11. Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts. 12. Avoid accidental starting. Be sure the Power Switch is off before plugging
Краткое содержание страницы № 5
21. Maintain tools with care. Keep cutting tools sharp and clean. Properly maintained tools with a sharp cutting edge are less likely to bind and are easier to control. Do not use a damaged tool. Tag damaged tools “Do not use” until repaired. 22. Check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the tool’s operation. If damaged, have the tool serviced before using. Many accidents are caused by poorly maintained tools. 23. Use only
Краткое содержание страницы № 6
5. Industrial applications must follow OSHA requirements. 6. Use the right tool or attachment for the right job. Do not attempt to force a small tool or attachment to do the work of a larger industrial tool. There are certain applications for which this product was designed. It will do the job better and more safely at the rate for which it was intended. Do not modify this product, and do not use this product for a purpose for which it was not intended. 7. Always turn off the Dust Collector a
Краткое содержание страницы № 7
outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician. GROUNDED TOOLS: TOOLS WITH THREE PRONG PLUGS 1. Tools and equipment marked with “Grounding Required” have a three wire cord and three prong gr
Краткое содержание страницы № 8
the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association, and the National Electrical Code. (See Figure B.) 2. Double insulated tools may be used in either of the 120 volt outlets shown in the following illustration. (See Figure B.) FIGURE B EXTENSION CORDS 1. Grounded tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord. 2. As the distance from the supply outlet increases, you must use a hea
Краткое содержание страницы № 9
electrician before using it. 8. Protect your extension cords from sharp objects, excessive heat, and damp or wet areas. RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120 VOLT) NAMEPLATE EXTENSION CORD LENGTH AMPERES (At Full Load) 25 50 75 100 150 FEET FEET FEET FEET FEET 0-2.0 18 18 18 18 16 2.1-3.4 18 18 18 16 14 3.5-5.0 18 18 16 14 12 5.1-7.0 18 16 14 12 12 7.1-12.0 18 14 12 10 - 12.1-16.0 14 12 10 - - 16.1-20.0 12 10 - - - *Based on limiting the line voltage drop to five volts at 150%
Краткое содержание страницы № 10
UNPACKING When unpacking, check to make sure all that all the parts listed in the Parts List on page 13 are included. If any parts are missing or broken, please call Harbor Freight Tools at the phone number shown on the front cover of this manual as soon as possible. ASSEMBLY INSTRUCTIONS NOTE: For additional information regarding the parts mentioned in the following pages, refer to the Assembly Diagram on page 14. To Attach The Four Casters To The Machine Base: 1. To attach the four Casters (3
Краткое содержание страницы № 11
4” DIAMETER FLEX HOSE CLAMP (NOT INCLUDED) (NOT INCLUDED) TO MACHINE OR INLET COVER VACUUM HOSE (25) ATTACHMENT FIGURE E OPERATING INSTRUCTIONS NOTE: For additional information regarding the parts mentioned in the following pages, refer to the Assembly Diagram on page 14. 1. NOTE: The Power Switch is equipped with a Safety Key (7) to prohibit unautho- rized starting of the Dust Collector. The Safety Key must be fully inserted into the Power Switch in order to turn the Power Switch to its “ON”
Краткое содержание страницы № 12
Power Cord Plug (1) from its electrical outlet. Then store the Dust Collector in a safe, clean, dry location out of reach of children and unauthorized users. POWER SWITCH (8) SAFETY KEY (7) COLLECTOR BAG (23) BRUSH COVER (3) BRUSH COVER (3) CARBON BRUSH (4) CARBON BRUSH (4) FIGURE F INSPECTION, MAINTENANCE, AND CLEANING 1. WARNING! Always make sure the Power Switch (8) is in its “OFF” posi- tion, and unplug the Power Cord/Plug (1) from its 120 volt electrical outlet before performing an
Краткое содержание страницы № 13
stops working completely. The Carbon Brushes are located on each side of the Motor Housing. To do so, remove the two Brush Covers (3). Then, remove the two Carbon Brushes. If the Carbon Brushes are worn down more than 1/2, replace both Carbon Brushes. If, however, the Carbon Brushes are just dirty they may be cleaned by rubbing them with a pencil eraser. When installing the Carbon Brushes, make sure the carbon portion of the Carbon Brushes contact the Motor Armature, and that the springs fa
Краткое содержание страницы № 14
ASSEMBLY DIAGRAM 7 89 1 10 2 11 12 13 17 28 4 3 18 19 20 21 22 5 6 27 26 14 25 28 29 29 28 16 24 15 23 29 28 30 32 31 35 41 36 37 40 38 39 34 33 NOTE: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. SKU 94029 For technical questions, please call 1-800-444-3353. Page 14