Краткое содержание страницы № 1
INSTALLATION INSTRUCTIONS
TM
DishDrawer dishwasher
DD24D 7 & DD24DT 7 models
US CA
590204B 12.11
Краткое содержание страницы № 2
2 1 FOLLOW THE INSTALLATION SEQUENCE RELEVANT TO YOUR MODEL STANDARD HEIGHT DOUBLE MODELS TALL HEIGHT DOUBLE MODELS Classic Designer Integrated Classic Designer Integrated DD24DCX7 DD24DCTX7 DD24DTI7 DD24DI7 DD24DCW7 DD24DDFX7 DD24DCHTX7 DD24DDFTX7 DD24DHTI7 DD24DCB7 DD24DCTW7 DD24DCTB7 PARTS SUPPLIED PARTS SUPPLIED PARTS SUPPLIED PARTS SUPPLIED PARTS SUPPLIED PARTS SUPPLIED OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING OPTIONALLY HARD WIRING OPTIONA
Краткое содержание страницы № 3
3 2a SAFETY AND WARNINGS - ALL MODELS IMPORTANT SAFETY INSTRUCTIONS! WARNING! Installation of this dishwasher requires basic mechanical and electrical skills. Electrical hazard Be sure to leave these Instructions with the Customer. Installation must comply with your local building, electricity, and plumbing regulations. Before installing the dishwasher, remove the house fuse or open the circuit breaker. If permanently connecting the dishwasher, be sure the power is isolated At
Краткое содержание страницы № 4
4 3a PARTS SUPPLIED - ALL MODELS Drain hose Drain hose Wire clip (2) Side mounting Top Phillips Rubber Clamp (1) support (1) joiner (1) bracket kit mounting 5⁄8” (16 mm) washer for (for securing (for securing (A and B) (2) brackets (2) screws (9) inlet hose (1) Drain hose joiner) Drain hose joiner) (comes already OPTIONAL OPTIONAL fitted) If the Drain hoses supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain
Краткое содержание страницы № 5
5 4 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION 4a 4b REMOVE THE LOWER DRAWER REMOVE THE ACCESS COVER & POWER CORD 4 3 4 5 Access 6 cover 1 To prevent kinked hoses, we recommend 8 rotating the drawer anti-clockwise and resting it on its side after removal. 5 7 WARNING! Press the release tabs in on 2 Electrical Shock Hazard either side and push back Before continuing, ensure that the product is to release drawer from disconnected from the power supply. runners. Failure to follow this warning
Краткое содержание страницы № 6
Integrated Designer Classic Integrated Designer Classic 6 5 PRODUCT DIMENSIONS O I K Plan D C F A N Side G O L B E M H J STANDARD HEIGHT MODELS TALL HEIGHT MODELS Product dimensions inches (mm) 1 2 2 2 2 2 2 overall height of product 32 5⁄16 - 34 5⁄8”( 820-880) 32 5⁄16 - 34 5⁄8”( 820-880) 32 5⁄16 - 34 5⁄8”( 820-880) 34 - 36 3⁄8”( 864-924) 34 - 36 3⁄8”( 864-924) 34 - 36 3⁄8”( 864-924) A B overall width of product 23 9⁄16”( 599) 23 9⁄16”( 599) 23 9⁄16”( 599) 23 9⁄16”( 599) 23 9⁄16”( 599) 23 9⁄16”
Краткое содержание страницы № 7
Integrated Designer Classic Integrated Designer Classic 7 6 CABINETRY DIMENSIONS Q Plan R S Side P Minimum clearances from adjacent cabinetry T min. ½ ” (13 mm) min. 1⁄16” (2 mm) clearance from a clearance corner cupboard to adjacent cupboard door Cabinetry dimensions inches (mm) STANDARD HEIGHT MODELS TALL HEIGHT MODELS P inside height of cavity* min. 32 5⁄16”( 820) min. 32 5⁄16”( 820) min. 32 5⁄16”( 820) min. 34”(864) min. 34”(864) min. 34”(864) Q inside width of cavity 23 5⁄8”( 600)
Краткое содержание страницы № 8
8 7a STANDARD HEIGHT INTEGRATED MODELS ONLY - CUSTOM PANEL CALCULATIONS The following calculations assume the top of the upper panel is FRONT PANEL SPECIFICATIONS aligned with the top of the adjacent cabinetry. The fi nal 5⁄8 - 13⁄16” (16-20 mm) panel thickness panel/cabinetry alignment is achieved by adjusting the feet: min. 1⁄16”(2mm) O O Adequately sealed to withstand moisture (122 F/ 50 C @ 80% RH) Maximum weight of each panel: 20 lb (9 kg) WIDTH OF ALL PANELS TOEKICK PANEL SPECIFIC
Краткое содержание страницы № 9
9 7b TALL HEIGHT INTEGRATED MODELS ONLY - CUSTOM PANEL CALCULATIONS The following calculations assume the top of the upper panel is FRONT PANEL SPECIFICATIONS aligned with the top of the adjacent cabinetry. The fi nal 5⁄8 - 13⁄16” (16-20 mm) panel thickness panel/cabinetry alignment is achieved by adjusting the feet: min. 1⁄16”(2mm) O O Adequately sealed to withstand moisture (122 F/ 50 C @ 80% RH) Maximum weight of each panel: 20 lb (9 kg) WIDTH OF ALL PANELS TOEKICK PANEL SPECIFICATIO
Краткое содержание страницы № 10
10 8 CAVITY PREPARATION Important! COUNTERTOP The power outlet must be located in a cabinet adjacent to the dishwasher cavity. Moisture 110-120 VAC max. 15 A 3⁄8” (10mm) protection Water Connection tape must be applied. Recommended HOT (Maximum 140°F/60°C). Supplied hose to suit 3⁄8” (9 mm) male compression fitting. These marks indicate Water Pressure formed bracket screw locations, if securing Water softener models by drawer removal. Max. 1 MPa (145 psi) If there is no side Min.
Краткое содержание страницы № 11
11 9 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE Right hand side Left hand side Drain hoses - 78 ½” (2000 mm) Drain hoses - 70 ½” (1800 mm) Inlet hose - 64 ¾” (1650 mm) Inlet hose - 49 ” (1250 mm) Power cord (excl. plug) - 27 ½” (700 mm) Power cord (excl. plug) - 29 ½” (750 mm)
Краткое содержание страницы № 12
12 NOW CHOOSE WHICH INSTALLATION METHOD (a) or (b) IS MORE SUITABLE FOR YOUR CABINETRY... RECOMMENDED METHOD (a) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 11a 10a PULL THROUGH HOSES & PUSH INTO THE CAVITY ATTACH SIDE MOUNTING BRACKETS optionally attach the Clip all four side mounting brackets into two top mounting brackets (x2) their slots using a flat-bladed screwdriver. A B Ensure they’re securely fitted before sliding product into cavity. Ensure the product is level B A
Краткое содержание страницы № 13
13 12a 13a SECURE TO THE CABINETRY ON THE SIDES OPTIONALLY SECURE TO THE CABINETRY ABOVE The top mounting 1 brackets will only bend (x2) Open the upwards a maximum drawer halfway. of 3⁄8” (10 mm). Using a flat-bladed screwdriver, prize the gray Replace the gray rubber plug out rubber plug back into of the trim moulding. the trim moulding and ensure the trim seal is facing forward. 2 3 Using a small Philips screwdriver, screw through the trim moulding, securing the side mounting bra
Краткое содержание страницы № 14
14
Краткое содержание страницы № 15
15 ALTERNATIVE METHOD (b) - SECURE BY DRAWER REMOVAL 10b PULL THROUGH HOSES & PUSH INTO THE CAVITY 11b REMOVE THE LOWER DRAWER To prevent kinked hoses, we recommend rotating the drawer counter-clockwise and resting it on its side after removal. optionally attach the 4 3 two top mounting brackets (x2) You can initially level the product 1 4 5 2 As you push product in, pull You can raise or lower the through hoses and cord, product by twisting the feet. Then take care when ensuring they don
Краткое содержание страницы № 16
16 12b SECURE TO THE CABINETRY ON THE SIDES 13b OPTIONALLY SECURE TO THE CABINETRY ABOVE To access the side brackets, The top mounting you might have to push aside brackets will only bend the insulation. After securing, (x2) upwards a maximum of ensure the sound insulation is 3⁄8”(10 mm). repositioned correctly. For further adjustment, using the most appropriate length Hexagonal socket supplied, fully extend leveling feet up to required distance by hand. Secure using two pairs of fo
Краткое содержание страницы № 17
17 15b FIT THE SUPPLIED TOEKICK PANEL (OPTIONAL FOR INTEGRATED MODELS) Where the toekick meets the bottom 1 3 5 7 of the tub is the Mounting rail cut-off point 19 9 Lay the toekick face down on Turn the toekick over and Smooth the edge with a file. a chopping board or similiar score along the same line Be careful of sharp edges. 4 6 8 Slide the toekick onto the mounting rails either side and screw 2 the toekick onto the bottom of tub on either side. Mark this point 19 on the toekick I
Краткое содержание страницы № 18
18 INTEGRATED MODELS ONLY - INSTALLING THE FRONT PANELS 16 17 ATTACH PANELS TO PANEL BRACKETS REMOVE BRACKETS FROM PRODUCT WARNING! 2 Electrical Shock Hazard 5⁄8”16 mm x6 (16mm) x6 There must be at least 1 3 screws used each side Before continuing, ensure that the product is disconnected from the power supply. Failure to follow this warning may result in electrical shock, injury or fire. Important! Break off and discard the tab at the top of the Lower Panel Bracket. 1 2 3 1 Align bottom of
Краткое содержание страницы № 19
INTEGRATED MODELS ONLY - INSTALLING THE FRONT PANELS 20 21 ADJUST PANEL HEIGHT TO ALIGN THE CABINETRY GAPS FITTING A CUSTOM TOEKICK PANEL 16 mm x5 5⁄8” (16mm) x5 + or - 1⁄16” (2 mm) With the front panels fitted, insert an appropriately sized Philips screwdriver into the hole above the door You can optionally glue your pin and rotate the panels up or down to align the gaps custom toekick panel onto the in your cabinetry. supplied panel Repeat on the other side if necessary. Each panel has
Краткое содержание страницы № 20
20 22 THERE ARE THREE DIFFERENT DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. Dishwasher and Standpipe Ø 1½ ” (38 mm) Dishwasher using Air Break with Drain Hose Joiner Dishwasher using sink trap with drain hose joiner If space is limited for fixing, push If space is limited hose through drain for fixing, push hose support to hose through drain required height hose support 2 2 Supplied drain hose joiner to required height Ø ¾ ” (19 mm) waste tee max. max. 4¾ ” 120 (120mm) mm 3 2