Resumo do conteúdo contido na página número 1
English
HEP HEP HEPAt At Atec ec ech+UV h+UV h+UVC C C
Germicidal Air Purifier
Owner’s Guide
Models
30770
30771
Form# 43059-01
20081106
©2008 Hunter Fan Co.
Resumo do conteúdo contido na página número 2
Table of Contents Safety Instructions .........................................................................................3 Introduction ....................................................................................................3 Description of Air Filtration System How the Air Purifier Works .............................................................................4 Air Purifier Components..................................................................
Resumo do conteúdo contido na página número 3
SAFETY INSTRUCTIONS IMPORTANT! READ ALL INSTRUCTIONS BEFORE USING THIS AIR PURIFIER. WARNING: This Air Purifier emits UV radiation that may cause eye and/or skin irritation. RG-3. Avoid exposing eyes and skin to unshielded UVC Lamp. Caution ! : The UVC Lamp may shatter and cause injury if it is dropped or sustains impact. Wear safety glasses and gloves when handling the UVC Lamp. Do not use excessive force when handling the UVC Lamp. Dispose of the UVC bulb in accordance with l
Resumo do conteúdo contido na página número 4
Description of Air Filtration System How the HEPAtech+UVC Air Purifier System Works As the air is pulled into the purifier, the activated carbon Pre-Filter absorbs odors and catches large particles. Then, the air travels through the HEPAtech® filter where the smaller particles are collected. Next, the air passes through the UVC Field, which helps reduce airborne pathogens such as germs, viruses, mold, and mildew. Then, the ionizer releases negative ions into the air that attract positively c
Resumo do conteúdo contido na página número 5
Description of Air Filtration System Display and Control Keys SPEED KNOB: Adjusts the blower speed and turns the unit on and off. PRE-FILTER RESET: Resets the Carbon Pre-Filter Life Counter. ® FILTER RESET / UVC RESET: Resets the HEPAtech Filter Life Counter; resets the UVC Lamp Life Counter. IONIZER KEY: Turns the Ionizer on and off. UVC KEY: Turns the UVC on and off. Ionizer Ionizer ® Sleep HEPAtech Key Off On / Off Filter Reset Indicator Filter Indica- Indicator / UVC Lamp tor Reset Ke
Resumo do conteúdo contido na página número 6
Operation Initial Operation This section provides basic instructions on the use of your Air Purifier. After following these ini- tial directions, please continue reading this booklet to learn how to operate the more advanced features of your Air Purifier. Basic Operation of the Air Purifier: 1. Take the Air Purifier out of the box and remove the clear plastic protective bag. Place the unit on a firm level floor. 2. Before turning on the unit, you need to confirm that the filters are firmly in
Resumo do conteúdo contido na página número 7
Operation purifier base Fig. 7 Fig. 6 6. Plug the unit into a 120V electrical outlet and turn the Speed Knob . The unit will start with a low blower speed. 7. Use the Speed Knob to adjust the blower speed to the desired level (Off, Sleep, Active, Turbo Clean). Refer to Fig. 8. OFF sleep active turbo clean Fig. 8 ©2008 HUNTER FAN CO. 43059-01 20081106 7
Resumo do conteúdo contido na página número 8
Operation Filter Life Counters The Pre-Filter and Filter are critical to the proper operation of the Air Purifier. To help you know when to change the filters, your Hunter Air Purifier has Filter Life Counters that will monitor the life of your filters. Although the exact life of the filters depends on the environment, the table below gives typical usage times of the filters. Table 2: Typical Usage Times of the Filters Filter Type Typical Usage Activated Carbon Pre-Filter 1400 hours ® HEPA
Resumo do conteúdo contido na página número 9
Air Purifier Maintenance Cleaning Your Air Purifier Proper maintenance of your Hunter Air Purifier will help ensure years of trouble free service. Follow these steps to properly maintain your Air Purifier: 1. Approximately every 90 days, the outside of the unit should be cleaned with a soft, damp cloth. 2. If needed, the Front Grill can be removed from the unit and cleaned with soapy water. Simply remove the Pre-Filter before exposing the Grill to water. 3. Follow the instructions in Changin
Resumo do conteúdo contido na página número 10
Air Purifier Maintenance Pre-Filter Hook Filter Tape Fig. 9 Fig. 10 Changing the Filter When the filter exceeds 2800 hours (approximately 4 to 6 months of use), the Filter indicator will turn on as a reminder that you should replace the filter. (Refer to Filter Life Counters for additional information, pg. 8.) This is a reminder that you should check the Filter and replace if necessary. The proper time to change the Filter depends on usage and the environment. Use the following list to help
Resumo do conteúdo contido na página número 11
Air Purifier Maintenance Changing the UVC Lamp When the UVC Lamp exceeds 8000 hours (approximately 1 year of use), the UVC Lamp filter Indicator will turn on as a reminder that you should replace the UVC Lamp to maintain airborne pathogen reduction capability. If necessary, the UVC Lamp can be changed more often. Refer to Obtaining Replacement UVC Lamps (pg. 14) if you need help finding replacement UVC Lamps. Change the UVC Lamp • after 8000 hours (approximately 1 year) of use, or • ever
Resumo do conteúdo contido na página número 12
Air Purifier Maintenance 5. Carefully lift the Lamp Cover Straight up, and remove it from the unit. Refer to Figs 12A and 12B. Fig. 12b Fig. 12A 6. Carefully twist the UVC Lamp until the lamp’s copper prongs are visible in the Lamp Sockets. Then, carefully remove the Lamp from the unit. Refer to Fig. 13. NOTE: HANDLE THE UVC LAMP CAREFULLY. IT MAY SHATTER IF IT IS DROPPED. DISPOSE OF THE UVC BULB IN ACCORDANCE TO LOCAL OR STATE REQUIREMENTS AS TRACE AMOUNTS OF MERCURY ARE PRESENT IN BULB. l
Resumo do conteúdo contido na página número 13
Air Purifier Maintenance 7. Carefully remove the Lamp from the unit. Refer to Fig. 14. Fig. 14 8. Carefully insert the new UVC Lamp’s copper prongs into the Lamp Sockets, and twist the Lamp until it is securely in place. 9. Position the Lamp Cover over the Lamp, and slide it downward until it is sceurely in place. NOTE: THE UNIT WILL NOT OPERATE IF THE LAMP COVER IS NOT INSTALLED CORRECTLY. 10. Install the Lamp Cover Screws. 11. Press the filter firmly into the Air Purifier. To avoid damaging
Resumo do conteúdo contido na página número 14
Air Purifier Maintenance Filter and l amp Ordering Depending on usage and the environment, your Carbon Pre-Filter should be replaced every three months and your Hepatech filter should be replaced every 6 months. The UVC lamp should be replaced every other time you replace your filter, or every year. Replacement filters are available at most retailers that carry Hunter Air Purifiers. You may also purchase directly from Hunter Fan Company by: Phone: 1-800-313-3326 Website: www.hunterfan.com *
Resumo do conteúdo contido na página número 15
Warranty Hunter Fan Company HEPAtech™ Air Purification System 5 YEAR LIMITED WARRANTY The Hunter Fan Company makes the following limited warranty to the original residential user or consumer purchaser of the HEPAtech™Air Purification System: If any part of your HEPAtech™ Air Purification System (“Air Purifier”) motor fails during the first five (5) years from the date of installation due to a defect in material or workmanship, we will provide a replacement Air Purifier free of charge. Insta
Resumo do conteúdo contido na página número 16
Warranty SOME AMERICAN STATES AND CANADIAN PROVINCES DO NOT ALLOW THE EXCLUSION OR INVALIDITY OF EXPRESS OR IMPLIED WARRANTIES IF THE USER CEASES TO OWN THE AIR PURIFIER, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE. Other Home Comfort Products from Hunter ® Hunter Original The Care-Free Programmable ™ Fans Humidifier Thermostat To learn more about Hunt
Resumo do conteúdo contido na página número 17
Español HEP HEP HEPAt At Atec ec ech+UV h+UV h+UVC C C Purificador de aire germicida Manual del propietario Modelos 30770 30771 Form# 43059-02 20081106 ©2008 HUNTER F ©2008 Hunter Fan Co. AN CO. 43059-01 20081106 17
Resumo do conteúdo contido na página número 18
Tabla de contenido Instrucciones de seguridad.............................................................................................19 Introducción ....................................................................................................................19 Descripción del sistema de filtrado de aire Cómo funciona el purificador de aire ..............................................................................20 Componentes del purificador de aire..........
Resumo do conteúdo contido na página número 19
INSTRUCCIONES DE SEGURIDAD ¡IMPORTANTE! LEA TODAS LAS INSTRUCCIONES ANTES DE USAR ESTE PURIFICADOR DE AIRE ! ADVERTENCIA: Este Purificador de aire emite radiación UV que puede causar irritación a los ojos y la piel. RG-3. Evite exponer los ojos y la piel a la lámpara UVC sin protector. Precaución: Lámpara UVC puede romperse y causar lesiones si se cae o recibe un impacto. Use lentes de seguridad y guantes al manipular la lámpara UVC. No use fuerza excesiva al manipular la lámpara UVC. Desech
Resumo do conteúdo contido na página número 20
Description of Air Filtration System Cómo funciona el sistema del Purificador de aire HEPAtech+UVC Mientras el aire es atraído hacia el purificador, el pre-filtro de carbón activado absorbe los olores y atrapa las partículas grandes. Luego, el aire viaja a través del filtro HEPAtech® donde se acumulan las partículas más pequeñas. Después, el aire pasa a través del campo UVC, que ayuda a reducir los patógenos en el aire como gérmenes, virus, moho y hongos. Luego, el ionizador libera iones ne