Resumo do conteúdo contido na página número 1
Installation Instructions for
Rayburn Cookmaster 200SFW
and Rayburn Cookmaster
Better than you ever imagined
Plus 212SFW Solid Fuel Cooker
Consumer Protection
where applicable, the pertinent parts that contain any of the listed
As responsible manufacturers we take care to make sure that our
materials that could be interpreted as being injurious to health and
products are designed and constructed to meet the required safety
safety, see below for information.
standard when properly installed and
Resumo do conteúdo contido na página número 2
Minimum clearance to combustible materials 150mm. Fig. 1 The cooker fully meets the requirements of BS: 1252 and towel rail are lagged. When the hot water storage and is fully approved by the HETAS Ltd Approval cylinder is very closely coupled to the boiler, a towel rail Scheme. is advisable as a heat leak, and lagging should not be applied. A radiator is not recommended. Air for combustion within the firebox and the rate of burning is determined by the manually operated To obtain the boiler out
Resumo do conteúdo contido na página número 3
IMPORTANT: LIFT OUT THE HOTPLATE AND AIR SUPPLY CEMENT SEAL THE JOINT BETWEEN THE BOILER FACE AND ITS LOCATING FACE ON THE FIREBOX SIDES WITH FIRE CEMENT. RENEW ANY Rayburn Cookmaster 200SFW: There is no BRICKWORK CEMENTED JOINTS THAT MAY HAVE requirement for additional ventilation as this appliance OPENED IN TRANSIT. is rated at less than 5kW. Should another appliance be used in the property and the total heat output is greater than 5 kW, additional ventilation must be provided in PREPARATION O
Resumo do conteúdo contido na página número 4
THE CHIMNEY The minimum chimney draught requirement for the 200SFW at nominal total heat output is 2.5 Pa. The minimum chimney draught requirement for the 212SFW at nominal total heat output is 12 Pa. The mean flue gas temperature of the Rayburn 200SFW directly downstream of the flue spigot at nominal heat output is 131ºC. The mean flue gas temperature of the Rayburn 212SFW directly downstream of the flue spigot at nominal heat output is 210ºC. The appliance is not suitable for installation in
Resumo do conteúdo contido na página número 5
IN ALL TYPE OF CHIMNEYS THE MINIMUM HEIGHT In Fig. 3 the cooker is connected direct to a brick flue. FOR CORRECT OPERATION OF THE CHIMNEY IS Horizontal pipe runs between cooker and brick flue 4.5m AND SHOULD TERMINATE ABOVE THE ROOF must not be used. IN ACCORDANCE WITH REGIONAL STATUTORY REQUIREMENTS RECOMMENDED FLUE DRAUGHT In Fig. 4 the cooker is connected to an existing brick - 12 pa MINIMUM. THE APPLIANCE SHOULD BE flue with a length of flue pipe. Square bends and INSTALLED AND CONFORM TO TH
Resumo do conteúdo contido na página número 6
HIGH UPDRAUGHTS Tall chimneys may develop excessively high updraughts which prevent the appliance operating correctly. It is recommended that a proprietary brand adjustable flue draught stabiliser having an openable cross 2 sectional area of 126cm be fitted above the flue pipe connection, either in the brickwork or into a right angle ‘T’ fitting in the flue pipe position that will not inconvenience appliance operation or maintenance. INSTALLATION Fig. 5 DESN 513152 Place the cooker in the intend
Resumo do conteúdo contido na página número 7
TESTING AND COMMISSIONING After completing the installation, the Heating Contractor should demonstrate to the user, the operation of the appliance and the routine flue operating method. 1. Check that the system is full of water and free from air pockets. (Rayburn Cookmaster Plus 212SFW only). 2. Select and install the appropriate burning grate as required by the customer (see Users Instructions for method). 3. When lighting pull the flue chamber damper open to maximum. 4. Add paper and stic
Resumo do conteúdo contido na página número 8
For further advice or information contact your local distributor/stockist With Aga’s policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to the appliance described at any time. Manufactured by Aga Station Road Ketley Telford Shropshire TF1 5AQ England www.aga-web.co.uk www.agacookshop.co.uk www.agalinks.com 8