Resumo do conteúdo contido na página número 1
SERVICE MANUAL
(INTERNATIONAL)
IMPINGER CONVEYOR OVENS
MODEL 1100 SERIES
Lincoln Foodservice Products, Inc.
1111 North Hadley Road
Fort Wayne, Indiana USA 46804
United States of America
Phone: (800) 374-3004 Fax: (260) 436-0735
Technical Service Hot Line
(800) 678-9511
www.lincolnfp.com
1100exportsvc REV: 12/8/05
Resumo do conteúdo contido na página número 2
TABLE OF CONTENTS SEQUENCE OFOPERATIONS 1104 THRU 1106...................................................... 3-4 SEQUENCE OF OPERATIONS 1134, 1135, 1136, 1150........................................... 5-6 SEQUENCE OF OPERATIONS 1151....................................................................... 7-8 SEQUENCE OF OPERATIONS 1152 THRU 1158.................................................... 9-11 SCHEMATIC 1104, 1105............................................................................
Resumo do conteúdo contido na página número 3
SEQUENCE OF OPERATIONS 1104 thru 1106 MODEL 1104 ELECTRIC 380/220 VAC 50 HZ 3 PHASE MODEL 1105 ELECTRIC 415/240 VAC 50 HZ 3 PHASE MODEL 1106 ELECTRIC 240 VAC 50 HZ 1 PHASE POWER SUPPLY Electrical power to be supplied to the oven by a five conductor service on Models 1104 and 1105 and a three conductor service on the 1106. MAIN FAN CIRCUIT Power is permanently supplied (through a 10A fuse) to the normally open contact of the main fan relay, the normally open cool-down thermostat and to the normal
Resumo do conteúdo contido na página número 4
The temperature portion of the Time/Temp Display uses a Thermistor Probe to sense oven temperature. The thermistor outputs a resistance proportional to the oven temperature. This resistance is then converted by the display into a temperature reading. AUTOMATIC COOL DOWN When the oven reaches operating temperature the normally open Oven Cool Down Thermostat closes. After the oven is switched OFF, the Ther mostat bypasses the Fan Switch, keeping the Cooling Fan and Main Fan in operation until the
Resumo do conteúdo contido na página número 5
SEQUENCE OF OPERATION 1134 - 1135 - 1136 - 1150 MODEL 1134 ELECTRIC 220/380 VAC 50 HZ 3 PHASE MODEL 1135 ELECTRIC 240/415 VAC 50 HZ 3 PHASE MODEL 1136 ELECTRIC 240 VAC 50 HZ 1 PHASE MODEL 1150 ELECTRIC 220/380 VAC 50 HZ 3 PHASE POWER SUPPLY Electrical power to be supplied to the oven by a three conductor service on single phase and a five conductor service on three phase. CONTROL BOX AUTO When the temperature in the control box reaches COOL DOWN 120°F ± 3°F (48.9°C ± 1.7°C), the Cooling Fan The
Resumo do conteúdo contido na página número 6
S/N 2011383 and above (cemented to tach. coupling) to break the infra-red light beam REFER TO PAGE B15 of the optical encoder(mounted on gear motor), producingelectri cal pulses that are transmitted to the display. The display con verts these pulses into a read-out of minutes and seconds. The temperature portion of the Time/Temp Display uses a Ther mistor Probe to sense oven temperature. The thermistor outputs a resistance proportional to the oven temperature. This resis tance is then converted
Resumo do conteúdo contido na página número 7
SEQUENCE OF OPERATIONS - 1151 MODEL 1151 ELECTRIC 200 VAC 60 HZ 3 PHASE POWER SUPPLY Electrical power to be supplied to the oven by a four conductor service. CONTROL BOX AUTO When the temperature in the control box reaches COOL DOWN 120°F ± 3°F (48.9°C ± 1.7°C), the Cooling Fan Thermostat closes, switching power to the Cooling Fans. The thermostat will open at 100°F ± 3°F(37.8°C ± 1.7°C) interrupting power to Cooling Fans. MAIN FAN CIRCUIT Power is permanently supplied through a 1A fuse to the p
Resumo do conteúdo contido na página número 8
The speed side of the Time/Temp. Display uses a slotted disc (cemented to tach. coupling) to break the infra-red light beam 2011383 and above of the optical encoder(mounted on gear motor), Refer to Page B15 producing electrical pulses that are transmitted to the display. The display converts these pulses into a read-out of minutes and seconds. The temperature portion of the Time/Temp Display uses a Thermistor Probe to sense oven temperature. The thermistor outputs a resistance proportional to t
Resumo do conteúdo contido na página número 9
SEQUENCE OF OPERATIONS 1152 thru 1158 MODEL 1152 NAT.GAS 220 VAC 50 HZ 1 PHASE MODEL 1153 L.P. GAS 220 VAC 50 HZ 1 PHASE MODEL 1154 NAT. GAS 240 VAC 50 HZ 1 PHASE MODEL 1155 L.P. GAS 240 VAC 50 HZ 1 PHASE MODEL 1156 TOWN.GAS 220/240 VAC 50 HZ 1 PHASE MODEL 1157 NAT. GAS 220/240 VAC 50 HZ 1 PHASE MODEL 1158 L.P. GAS 220/240 VAC 50 HZ 1 PHASE POWER SUPPLY Electrical power to be supplied to the oven by a three conductor service. CONTROL BOX AUTO COOL DOWN When the temperature in the Control Box rea
Resumo do conteúdo contido na página número 10
adjusted to desired temperature. The Thermocouple will provide varying millivolts to the Electronic Temperature Controller. The electronic tempera- ture controller supplies 120 VAC to the Solenoid Valve at intermittent intervals to maintain desired temperature. CONVEYOR DRIVE Closing the Conveyor Switch supplies 120 VAC to the D.C. Motor Control Board at terminals L1 and L2. AC volts are converted to DC volts and are supplied to the Conveyor Motor at terminals A+ and A- . Adjustment of the
Resumo do conteúdo contido na página número 11
NOTE: The Conveyor Control uses a sensor and magnet, mounted on the Conveyor Motor that senses when the motor is not turning. If the motor is not turning, the Time/Temp Display will show : in the window. The temperature portion of the display uses a Thermistor Probe to sense oven temperature. The Thermistor outputs a resistance proportional to oven temperature. This resistance is then converted by the Display into a temperature reading. OR: The temperature potion of the display uses a J
Resumo do conteúdo contido na página número 12
SCHEMATIC 1104-1105 12 Impinger II - 1100 Series Service Manual - International
Resumo do conteúdo contido na página número 13
SCHEMATIC 1106 Impinger II - 1100 Series Service Manual - International 13
Resumo do conteúdo contido na página número 14
SCHEMATIC 1134, 1135, 1150, S/N 2011383 AND BELOW 14 Impinger II - 1100 Series Service Manual - International
Resumo do conteúdo contido na página número 15
SCHEMATIC 1134, 1135 S/N 2011383 AND ABOVE 15 Impinger II - 1100 Series Service Manual - International
Resumo do conteúdo contido na página número 16
SCHEMATIC 1150 S/N 2011383 AND ABOVE Impinger II - 1100 Series Service Manual - International 16
Resumo do conteúdo contido na página número 17
SCHEMATIC 1136, S/N 2011383 AND BELOW Impinger II - 1100 Series Service Manual - International 17
Resumo do conteúdo contido na página número 18
SCHEMATIC 1136, S/N 2011383 AND ABOVE 18 Impinger II - 1100 Series Service Manual - International
Resumo do conteúdo contido na página número 19
SCHEMATIC 1151 S/N 2011383 AND BELOW Impinger II - 1100 Series Service Manual - International 19
Resumo do conteúdo contido na página número 20
SCHEMATIC 1151 S/N 2011383 AND ABOVE 20 Impinger II - 1100 Series Service Manual - International