Resumo do conteúdo contido na página número 1
- For Administrator -
For Microsoft Windows CE.NET
Version E
Please confirm the version of the software built in eClient, and refer to
the suited User's Manual (Refer to the User's Manual Version List on
next page).
This is the manual for the following software version.
* Microsoft Windows CE: 4.0 Rev. 2.3.2 or later
* Microsoft Terminal Server Client: Ver. 7.2.1 or later
* ICA Client: Ver. 7.23 or later
Resumo do conteúdo contido na página número 2
User’s Manual Version List A handling description changes with versions of the software built in eClient. Please refer to below. NOTE • The version of software built in eClient can be checked with a [System]-[ICA] tab of [Terminal Properties]. OS: Microsoft Windows CE .NET Software Microsoft ICA Client Microsoft Windows CE Windows Software Manual Terminal Server E 4.0 Rev.2.3.2 or later Version 7.2.1 or later Version 7.23 or later (This Manual) D 4.0 Rev.2.3.0 or later Versio
Resumo do conteúdo contido na página número 3
SAFETY SYMBOLS This manual uses the safety symbols below. They denote critical information. Please read them carefully. WARNING Failure to abide by the information in a WARNING may result in serious injury and can be life threatening. CAUTION Failure to abide by the information in a CAUTION may result in moderate injury and/or property or product damage. Indicates a prohibited action. Indicates to ground for safety. Copyright© 2003-2004 EIZO NANAO CORPORATION All rig
Resumo do conteúdo contido na página número 4
TABLE OF CONTENTS 1. INTRODUCTION..................................................................................... 5 1-1. General Description ......................................................................................5 1-2. Features ........................................................................................................5 1-3. Package Contents..........................................................................................6 1-4. Controls & Connectors .
Resumo do conteúdo contido na página número 5
1. INTRODUCTION Thank you very much for purchasing the EIZO eClient 620L. 1-1. General Description The eClient 620L connects with a Windows Terminal Server*, which installed Microsoft Windows NT Server 4.0 Terminal Server Edition or Windows 2000 Server/Advanced Server/Datacenter Server, and this product is used as a terminal using them. Windows Terminal Server (WTS) eClient 620L Output data of applications Input data from mouse/keyboard · Display data · Operation of application
Resumo do conteúdo contido na página número 6
1-3. Package Contents Please make sure that all the items listed are in the package. Please contact your local dealer for assistance if any of the listed items are missing or damaged. • eClient 620L • Mouse (FDM-L30S) • Power Cord • Screw (M4 x 12 mm) x 4 • User’s Manual (includes Limited Warranty) • 2 Stickers of the Brightness Control Guide NOTE • A keyboard is not included. Please purchase a USB keyboard separately. [The keyboards, which have been confirmed worki
Resumo do conteúdo contido na página número 7
1-4. Controls & Connectors Front (1) (2) (3)(4) (1) (1) Speakers (2) Volume Control (3) Power Indicator Color 620L status Green • Operation • Screen saver mode Yellow Power save mode Off • Suspend mode (Wake on LAN standby) • Power off (Wake on LAN standby) (4) Power button NOTE • When turning off/on the unit, leave the unit off for a few seconds before turning it on again. 1. INTRODUCTION 7
Resumo do conteúdo contido na página número 8
Rear (12) (11) (13) (5) (6) (7)(8) (9) (10) (5) Power Connector (6) Ethernet Connector (10 Base-T, 100 Base-TX) (7) Headphone Connector (8) Microphone Connector (9) Serial Port (RS-232C) (10) USB Port (Downstream) x 2 1 (11) Security Lock* 2 (12) Holes for Mounting an Arm Stand* (13) Stand (Detachable) 1 * This allows for connection of a security cable. This lock supports Kensington’s MicroSaver security system. For further information, please consult: Kensington Technolog
Resumo do conteúdo contido na página número 9
2. CONNECTING THE eClient 620L This chapter explains how to connect the eClient 620L to a WTS. 2-1. Setting up the eClient 620L NOTE • Before connecting the product, set up the monitor after unfolding the base of the stand. WARNING Place the eClient 620L on a strong, stable surface. A unit placed on an inadequate surface may fall, resulting in injury or equipment damage. If the unit falls, disconnect the power immediately and have the unit checked by a qualified servic
Resumo do conteúdo contido na página número 10
2-2. Connecting the eClient 620L NOTE Before connecting the eClient 620L, confirm the following: - The eClient 620L is turned off. - The WTS is turned on. • Connect the peripherals to the appropriate connectors of the unit. 1. In case of connecting the WTS through LAN: Connect the eClient 620L to the network with an Ethernet cable. In case of a dial-up or dial-in connection: Connect the eClient 620L to a modem or a modem card. 2. Plug a keyboard and a mouse into the eClient 620L.
Resumo do conteúdo contido na página número 11
3. SETTING UP the eClient 620L This chapter presents how to prepare for a connection with a WTS when the eClient 620L starts up for the first time. 1. Turn on the eClient 620L. The power indicator turns green and a picture appears on the screen. NOTE • When no picture is displayed, or when the message (No keyboard connected. / No mouse connected.) is shown on the screen, please refer to “8. Troubleshooting” on page 57. 2. “eClient Setup Wizard” is displayed. (Set up the 620L accordin
Resumo do conteúdo contido na página número 12
3. End User License Agreement page is displayed. Read the content and click [Accept] to continue. 12 3. SETTING UP the eClient 620L
Resumo do conteúdo contido na página número 13
4. Set up the network environment. [Terminal Name] ................Type the name to identify this unit on the network. Click [Network Properties] and set up connection information according to the connection method to WTS/Web server. NOTE • In use of the dial-in connection (ICA protocol only) to log on to WTS, click [Next] to go procedure 5. 3. SETTING UP the eClient 620L 13
Resumo do conteúdo contido na página número 14
In case of connecting the WTS/Web through LAN: (1) Double-click [Built-in LAN] icon [IP Address] ........................Type the IP address of the unit. [Name Servers]....................Type the IP address of each server when DNS or WINS is used. [Advanced]..........................Type the transmission speed and MAC Address of a network. 14 3. SETTING UP the eClient 620L
Resumo do conteúdo contido na página número 15
In case of a dial-up connection: (1) Double-click [Make New Connection] icon. (2) Type a name for the connection and select the connection type (Dial-Up Connection). (3) Select a model, set up the TCP/IP settings and Security settings. (4) Type the phone number for the connection. (5) In case of a dial-up connection, the information of local location needs to be set up. Set up the information in the later procedure 8. NOTE • When you use VPN (Virtual Private Network), set up the connec
Resumo do conteúdo contido na página número 16
5. Set up the desktop area. [Desktop Area and Refresh Frequency] ...................................Set the resolution/refresh rate. (The 620L supports 1024 x 768 @60 Hz only). If using this product with portrait orientation, select the [Portrait display] check box. [Desktop Colors].................Set the desktop color (256 Colors / High color) of the following. - Windows CE desktop (before WTS connection) - Windows desktop (after a WTS connection with RDP protocol) NOTE • After
Resumo do conteúdo contido na página número 17
6. Set up the browser connection. Set up if you are setting up a web browser connection. (1) Select [Internet Options] icon and click [Open]. [General].............................Set up the browser. [Connection].......................Set up the connection method to the browser. [Security].............................Set up the security for the connection to the browser. [Advanced]..........................Set up the display method of the browser. 7. Set up the printer. Set up if
Resumo do conteúdo contido na página número 18
8. Setup the Local sender’s setting Setup if you are connecting to WTS/Web server by dial-up connection. (1) Select [Dialing] icon and click [Open] icon. [Location name]..................Choose the sender’s location (click [New] to add a new sender’s location). [Local Settings are:].............Setup the local settings. 9. The last page of the “eClient Setup Wizard” is displayed. Click [Finish]. Click [Yes] if a “Terminal Settings change” dialog box is displayed. The “Terminal
Resumo do conteúdo contido na página número 19
4. ADDING & CHANGING A CONNECTION NAME This chapter shows how to add, delete, and modify connection names to a WTS. All the settings are managed in the “Terminal Connection Manager”. 4-1. Adding a Connection Name These are settings for the server connection. Each protocol has different settings. Please install the appropriate settings. • In use of the Microsoft Remote Desktop Client (RDP) page 20 • In use of the Citrix ICA Client (ICA) page 21 NOTE • Please install Citrix Me
Resumo do conteúdo contido na página número 20
In Use of RDP Protocol 1. Display [Terminal Connection Manager]. Click the [Configure] tab and [Add...] to set the connection information of the WTS. 2. Protocol selection dialog box is displayed. Select the “Microsoft Remote Desktop Client” (RDP). 3. “WTS Connection Wizard” is displayed. (Setup as following the wizard.) (1) Type the connection name and the name of the Server. (2) Setup to enable an Automatic Logon to the WTS after connecting if you want. (3) Select whether to dis