Resumo do conteúdo contido na página número 1
WHYNTER 13,000 BTU DUAL HOSE PORTABLE AIR CONDITIONER
c o
MODEL# : ARC-131GD
Instruction Manual
Congratulations on your new WHYNTER product. To ensure proper operation, please read this Instruction
Manual carefully before using this product. Keep this manual in a safe place for future reference.
Resumo do conteúdo contido na página número 2
TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 4-5 IDENTIFICATION OF ACCESSORIES 6 IDENTIFICATION OF PARTS 7 INSTALLATION INSTRUCTIONS 8-9 AIR FILTERS INSTALLATION 10 REMOTE CONTROL 11 OPERATION INSTRUCTIONS 11-14 WATER DRAINAGE 14 CARE AND MAINTENANCE 15 TECHNICAL DATA 16 TROUBLESHOOTING 17-18 WARRANTY INFORMATION 19 2 | P a g e
Resumo do conteúdo contido na página número 3
Thank you for choosing the Whynter portable air conditioner. Please follow the instructions provided in this user guide to obtain the very best performance from your portable air conditioner and take full advantage of the many features your portable air conditioner offers you. We trust that your Whynter air conditioner will provide the performance and reliability that we stand for. Please keep this user manual in a safe place for future reference. DISPOSAL This symbol o
Resumo do conteúdo contido na página número 4
Your safety and the safety of others are very important to us. To reduce the risk of fire, electrical shock or injury when using your appliance, follow these basic precautions. SAFETY PRECAUTIONS Before the portable air conditioner is used, it must be properly positioned and installed as detailed in this manual. Do not under any circumstances cut or remove the third (ground) prong from the power cord. Make sure this unit is connected to a correctly grounded power
Resumo do conteúdo contido na página número 5
Keep fingers out of the air intakes and air outlets. The unit is an electrical appliance. To avoid injury from electrical shock do not operate it with wet hands, while standing on a wet surface or while standing in water. Do not use it in outdoors or in wet conditions. When positioning or moving the unit, ensure it is not turned upside down or greater than 45° or more off level. This unit is designed for household, non-commercial use only. Any other use will void the warranty.
Resumo do conteúdo contido na página número 6
IDENTIFICATION OF ACCESSORIES IMAGE ACCESSORY NAME QUANTITY Small Hose for Exhaust 2 pieces Large Hose for Intake Fixture 2 pieces Screws 8 pieces Hose connectors 4 pieces 2 curved connectors are for large hose 2 straight connectors are for small hose 1 set Window slider kit Cover 2 pieces Remote control 1 piece Optional Intake pre-filter (sold separately) 1 piece 6 | P a g e
Resumo do conteúdo contido na página número 7
IDENTIFICATION OF PARTS Front 1. Remote control 2. Front display 3. Air outlet 4. Handle 5. Wheels Rear 6. Air filter 7. Air intake (evaporator) 8. Air exhaust (for small hose) 9. Air intake (for large hose) 10. Power cord 11. Upper drain port 12. Lower drain port 7 | P a g e
Resumo do conteúdo contido na página número 8
INSTALLATION INSTRUCTIONS Location The air conditioner should be placed on a hard and level surface strong enough to support the unit. The unit has casters and it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects. Never place any obstacles around the air inlet or outlet and allow at least 20 inch of clearance for efficient air-conditioning. Exhaust hose Installation When you use this air conditioner
Resumo do conteúdo contido na página número 9
Window kit Installation When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in dehumidifying and fan-only mode, no exhaust is required. Your window kit has been designed to fit most standard vertical and horizontal windows. However, it may be necessary for you to modify the installation procedures for your window. NOTE: If your window opening is less than the mentioned minimum length
Resumo do conteúdo contido na página número 10
AIR FILTERS INSTALLATION Your Whynter portable air conditioner is equipped with a washable Pre-Filter and an activated carbon filter. The washable Pre-Filter removes large particles such as dust, pet hair and dander. The activated carbon filter is designed to remove smoke and other odors. It is recommended to replace the activated carbon filter every 2-3 months. Follow the steps below to install the filters. WARNING: NEVER OPERATE THE AIR CONDITIONER WITHOUT THE PRE-FILTER 1. Pul
Resumo do conteúdo contido na página número 11
OPERATION INSTRUCTIONS Before you begin, thoroughly familiarize yourself with the control panel of the remote control. Follow the symbol for the desired function. The functions of the unit can be controlled by the remote control only. When using the remote control, make sure the reception of the signal is confirmed by a beep. NOTE: Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may cause interferences. Electronic and fluorescent lamps may
Resumo do conteúdo contido na página número 12
FRONT PANEL SWITCHING ON/OFF THE AIR CONDITIONER The unit can be switched ON or OFF by pressing the Emergency on/off switch button on the front display panel or the remote control. NOTE: The functions of the portable air conditioner can be switched on by the remote control ONLY. Without using the remote control, the unit can only be switched on at the previous setting and turn off the unit. LED LAMPS ON/OFF SWITCH Press the LED lamps on/off switch to
Resumo do conteúdo contido na página número 13
DEHUMIDIFYING MODE In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on the ambient temperature. To activate this function mode, press the Mode Control button until the indicator comes on. When the dehumidifying mode is set, the orange light on the front panel comes on. Please note that when switching function mode, there will be an approximately 3 minute transition time. In dehumidifying mode, do not connect the exhaus
Resumo do conteúdo contido na página número 14
SETTING SWITCH OFF TIMER With the air conditioner operating in any function mode, press the Timer Control button . Then the and the two digits timer indicator will come on. Set the desired time delay OFF hours (1 – 24 hours) by pressing the up or down buttons. When the delay time set has elapsed, the air conditioner will switch off. To cancel the switch off timer, press the Timer Control button and set the hour to 00. SETTING DELAYED SWITCH ON TIMER When the air conditioner is off,
Resumo do conteúdo contido na página número 15
CARE AND MAINTENANCE IMPORTANT: Switch off the air conditioner and disconnect the plug from the power outlet Drain water by removing the drain plug. Always transport the air conditioner in an upright position only. CLEANING THE PRE-FILTER To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is recommended to clean the Pre-filter at least once every two weeks. Switch off the air conditioner and pull out the filter frame fr
Resumo do conteúdo contido na página número 16
TECHNICAL DATA Model ARC-131GD Cooling capacity 13,000 BTU Power supply 115v/ 60Hz Maximum power input 1180 Watts Maximum input 10.8 Amps Dehumidifying capacity 91 Pts / Day Thermostat 61°F to 89°F Refrigerant R-410A Air flow (max.) 320 m3/ Hour Exhaust hose length 47” Unit Dimensions 17.3” W x 15.4” D x 30.5” H Package Dimensions 18.7” W x 19.5”D x 35”H Unit Weight 67 lbs 16 | P a g e
Resumo do conteúdo contido na página número 17
TROUBLESHOOTING Problem Possible Causes Solutions The portable air Power failure / outage. Restore the power supply. conditioner does not turn on The automatic switch, line Flip the switch / change the fuse / turn the breaker fuse, or breaker has been back on. Also note that you may have too many tripped. appliances drawing power on one circuit, you may need to move the other appliances to another circuit. The power supply voltage is Move the unit onto another cir
Resumo do conteúdo contido na página número 18
The air coming out of The filters are dirty or Clean the air filters. the unit is not very obstructed. cold, or the airflow The air intake or exhaust is Make sure there is at least 20" of clearance from volume is weak obstructed. the air intake. Make the length of the exhaust hose is as short as possible. The unit is set in DRY or Set the unit to the cooling mode. FAN mode. The unit is set to low fan Set the unit to a higher fan speed. speed. Windows or doors
Resumo do conteúdo contido na página número 19
ONE YEAR LIMITED WARRANTY & THREE YEAR WARRANTY ON COMPRESSOR This WHYNTER portable air conditioner is warranted, to the original owner within the 48 continental states, for one year from the date of purchase against defects in material and workmanship under normal use and service. Should your WHYNTER portable air conditioner prove defective within one year from the date of purchase, return the defective part or unit, freight prepaid (within two months of purchase; after two months to