Resumo do conteúdo contido na página número 1
WHYNTER ECO-FRIENDLY 10,000 BTU PORTABLE AIR CONDITIONER
co
MODEL# : ARC-10WB
Instruction Manual
Congratulations on your new WHYNTER product. Please read this Instruction Manual carefully before using
this product to ensure proper operation. Keep this manual in a safe place for future reference.
Resumo do conteúdo contido na página número 2
TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 4-5 IDENTIFICATION OF ACCESSORIES 6 IDENTIFICATION OF PARTS 7 OPERATING YOUR AIR CONDITIONER 8 INSTALLATION INSTRUCTIONS 9-12 AIR FILTERS INSTALLATION 13 OPERATION INSTRUCTIONS 14-15 WATER DRAINAGE 16 REMOTE CONTROL 17 CARE AND MAINTENANCE 18 TECHNICAL DATA 19 TROUBLESHOOTING 20-21 WARRANTY INFORMATION 22 2 | P a g e
Resumo do conteúdo contido na página número 3
Thank you for choosing the Whynter portable air conditioner. Please follow the instructions provided in this user guide to obtain the very best performance from your portable air conditioner and take full advantage of the many features your portable air conditioner offers you. We trust that your Whynter air conditioner will provide the performance and reliability that we stand for. Please keep this user manual in a safe place for future reference. DISPOSAL
Resumo do conteúdo contido na página número 4
Your safety and the safety of others are very important to us. To reduce the risk of fire, electrical shock or injury when using your appliance, follow these basic precautions. SAFETY PRECAUTIONS Before the appliance is used, it must be properly positioned and installed as detailed in this manual. Do not under any circumstances cut or remove the third (ground) prong from the power cord. Make sure this unit is connected to a corre
Resumo do conteúdo contido na página número 5
Do not allow children to climb, stand or hang on the appliance. The air conditioner could tip over and get damaged and/or seriously injure somebody. Keep fingers out of the air intakes and air outlets. The appliance is an electrical appliance. To avoid injury from electrical shock do not operate it with wet hands, while standing on a wet surface or while standing in water. Do not use it in outdoors or in wet conditions. When positioning or moving the appliance, ensure it is not tur
Resumo do conteúdo contido na página número 6
IDENTIFICATION OF ACCESSORIES IMAGE ACCESSORY NAME QUANTITY Exhaust hose and Adaptor (flat mouth) 1 set Round adaptor 1 set Wall exhaust adaptor 1 pc Expansion plug and wooden screw 4 pcs 1 set Window slider kit Foam seal 3 pcs Remote control & Batteries 1 set Drain hose 1 pcs 6 | P a g e
Resumo do conteúdo contido na página número 7
IDENTIFICATION OF PARTS Front 1. Control Panel 2. Front Air Vent / Louvers 3. Caster (four) 4. Handle (both sides) Rear 6 6. Upper air filter 7. Air outlet (hot air exhaust) 8. Power cord outlet 9. Upper air intake 10. Upper drain port 11. Lower air intake (Compressor) 12. Lower air filter 13. Lower drain port 7 | P a g e
Resumo do conteúdo contido na página número 8
OPERATING YOUR AIR CONDITIONER Before you begin, thoroughly familiarize yourself with the control panel, remote control and all of the functions. Follow the symbol for the desired function. The unit can be controlled by the unit control panel alone or with the remote control. CONTROL PANEL 1. MODE 6. UP & DOWN Controls the 4 function modes: COOL, AUTO, Fan only O O Adjusts set temperature (1 C/ 2 F increments) or timer & DRY. hours (0 – 24 hours). NOTE
Resumo do conteúdo contido na página número 9
INSTALLATION INSTRUCTIONS Location The air conditioner should be placed on a hard and level surface strong enough to support the unit. The unit has casters and it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects. Never place any obstacles around the air inlet or outlet and allow at least 20 inch of clearance for efficient air-conditioning. Exhaust hose Installation When you use this air conditioner
Resumo do conteúdo contido na página número 10
Window kit Installation When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in fan-only mode, no exhaust is required. Your window kit has been designed to fit most standard vertical and horizontal windows. However, it may be necessary for you to modify the installation procedures for your window. Please refer to Fig. 8 & Fig.9 for minimum and maximum window openings. NOTE: If your
Resumo do conteúdo contido na página número 11
Window kit Installation in a double-hung window 1. Open window or sliding door for approximately 5” 2. Cut the foam seal (adhesive type) to the proper length and attach it to the bottom of the window. Fig.10. 3. Adjust the length of the window bars to the same length and width of the opening of the window. Cut the window piece if necessary to fit the length of your window. Fig. 11. 4. Close the window on the window slide bars. For long term installation, you may screw
Resumo do conteúdo contido na página número 12
Window kit Installation in a sliding door/ window 1. Open window or sliding door for approximately 5” 2. Cut the foam seal (adhesive type) to the proper length and attach it to the bottom of the door / window. Fig.14. 3. Adjust the length of the window bars to the same length and width of the opening of the window. Cut the window piece if necessary to fit the length of your window. Fig. 15. 4. Close the door/ window on the window slide bars. For long term installation, y
Resumo do conteúdo contido na página número 13
AIR FILTERS INSTALLATION Your Whynter portable air conditioner is equipped with a washable Pre-Filter and a Silver Ion Filter. The washable Pre-Filter removes large particles such as dust, pet hair and dander. The Silver Ion air filter which is designed to kills bacteria in the air and controls the growth of microbes, such as virus, fungi and spores. It is recommended you replace the Silver Ion Filter every two to three months or as needed. Follow the steps below to install the filters. WA
Resumo do conteúdo contido na página número 14
OPERATION INSTRUCTIONS BEFORE USING YOUR APPLIANCE Remove the exterior and interior packing. Before connecting the appliance to the power source, let it stand upright for approximately 4 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation. SWITCHING ON/OFF THE AIR CONDITIONER The appliance can be switched ON or OFF by pressing the Power button on the control panel or the Power button on the remote control. COOLIN
Resumo do conteúdo contido na página número 15
TIMER (DELAYED SWITCH ON / OFF) FUNCTION This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time (hours) delay can be set, enabled and disabled. SETTING SWITCH OFF TIMER With the air conditioner operating in any function mode, press the TIMER button. The TIMER OFF light will come on. Then set the desired time delay OFF hours by pressing the UP and DOWN buttons. The time increments are at 0.5 hour to up to 10 hours, followed by 1 hour in
Resumo do conteúdo contido na página número 16
WATER DRAINAGE When the water level of the bottom tray reaches maximum level, the unit will beep 8 times and the digital display will show P1 symbol. Also, the cooling or dehumidifying function will stop and the fan only function will start. Manual drainage To drain the water from the bottom try, carefully move the unit to a drain location, remove the bottom drain plug and let the water drain (Fig.25). The P1 symbol will disappear and the cooling or dehumidifying function can
Resumo do conteúdo contido na página número 17
REMOTE CONTROL The portable air conditioner can be switched on by the remote control. To transmit signals from the remote control to the air conditioner, point the front part of the remote handset towards the control panel on the air conditioner. Reception of the signal is confirmed by a beep. The maximum signal transmission distance is approximately 8 meters / 26 feet. NOTE: Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may cause interfere
Resumo do conteúdo contido na página número 18
CARE AND MAINTENANCE IMPORTANT: Switch off the air conditioner and disconnect the plug from the power outlet Drain water by removing the drain plug. Always transport the air conditioner in an upright position only. CLEANING THE AIR FILTERS To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is recommended to clean the air filters at least once every two weeks. This unit has two air filters; the upper and the lower f
Resumo do conteúdo contido na página número 19
TECHNICAL DATA Cooling capacity 10,000 BTU Power supply 115v/ 60Hz Maximum power input 1170 Watts Maximum input 10.1 Amps Dehumidifying capacity 55 Pts / Day Thermostat 62°F / 17°C to 88°F / 30°C Refrigerant R-410A Air flow (max.) 380 m3/ Hour Fan speeds 3 (Auto, H, M, L) Exhaust hose length 48” / 4‟ Unit Dimensions 17” W x 13.6” D x 28” H Unit Weight 64 lbs 19 | P a g e
Resumo do conteúdo contido na página número 20
TROUBLESHOOTING Problem Possible Causes Solutions The portable air Power failure / outage. Restore the power supply. conditioner does not turn on The automatic switch, line Flip the switch / change the fuse / turn the fuse, or breaker has been breaker back on. Also note that you may have tripped. too many appliances drawing power on one circuit, you may need to move the other appliances to another circuit. Move the unit onto another circuit with the The power supply voltage i