Resumo do conteúdo contido na página número 1
RuggedBackbone™
RX1501
Hardware Installation Guide
Revision 104 - October 14, 2011
www.RuggedCom.com
Resumo do conteúdo contido na página número 2
RuggedBackbone™ RX1501 RuggedBackbone™ RX1501: Hardware Installation Guide Copyright © 2011 RuggedCom Inc. All Rights Reserved Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations are liable for damages. All rights are reserved, particularly for the purposes of patent application or trademark registration. This document contains proprietary information, which is protected by copyright. All
Resumo do conteúdo contido na página número 3
RuggedBackbone™ RX1501 Table of Contents FCC Statement And Cautions ................................................................................................... 8 1. Product Overview ................................................................................................................... 9 1.1. Functional Overview .................................................................................................... 9 1.2. Feature Highlights ........................................
Resumo do conteúdo contido na página número 4
RuggedBackbone™ RX1501 3.14. APE: Application Processing Engine ...................................................................... 35 3.14.1. APE Overview .............................................................................................. 35 3.14.2. Supported Operating Systems ..................................................................... 35 3.14.3. Secondary Network Interface ....................................................................... 36 3.14.4. Installing an O
Resumo do conteúdo contido na página número 5
RuggedBackbone™ RX1501 List of Figures 2.1. RX1501 Chassis Slot Assignment .................................................................................... 12 2.2. Front View - RX1501 ........................................................................................................ 13 2.3. CG01: 2 × 10/100/1000TX RJ45 ...................................................................................... 14 2.4. 6TX01: 6 × 10/100/1000TX RJ45 .............................................
Resumo do conteúdo contido na página número 6
RuggedBackbone™ RX1501 3.20. RJ45 Serial Pin Configuration ......................................................................................... 28 3.21. RJ45 DDS Pin Configuration .......................................................................................... 28 3.22. DDS Module Rx and Tx LED Indicators ......................................................................... 29 3.23. SFP module orientation .........................................................................
Resumo do conteúdo contido na página número 7
RuggedBackbone™ RX1501 List of Tables 2.1. Module Status LED Indications ......................................................................................... 13 3.1. DB9 Serial Console Pinout ............................................................................................... 25 3.2. RJ45 T1/E1 Pin Assignment ............................................................................................. 25 3.3. RJ45 Ethernet Pin Assignment ..........................................
Resumo do conteúdo contido na página número 8
FCC Statement And Cautions FCC Statement And Cautions Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed
Resumo do conteúdo contido na página número 9
1. Product Overview 1. Product Overview 1.1. Functional Overview The RuggedBackbone™ RX1501 is a cost-efficient, rugged layer 3 switch and router. The RX1501’s modular and field replaceable platform allows you to select WAN, serial, and Ethernet options, making it ideally suited for electric power utilities, the industrial plant floor, and traffic control systems. The RX1501 is designed to the RuggedRated™ specification, providing a high level of immunity to electromagnetic interference (EMI) an
Resumo do conteúdo contido na página número 10
1. Product Overview WAN Port Options • Up to 4 T1/E1 ports via RJ45 connectors (channelized/unchannelized) • Up to 2 E1 ports via BNC connectors (channelized/unchannelized) • Cellular/DDS Serial Ports • Fully compliant EIA/TIA RS485, RS422, RS232 serial ports (software selectable) with RJ45 connectors • Raw socket mode support allows conversion of any serial protocol Protocols WAN • • Frame Relay RFC 1490 or RFC 1294 • PPP RFC 1661, 1332, 1321, 1334, PAP, CHAP Authentication • Multilink PPP RFC
Resumo do conteúdo contido na página número 11
1. Product Overview Universal Power Supply Options • Single, removable power supply module • Single power supply • Fully integrated power supply (no external adaptor) • Input voltage ranges: 10-36VDC, 36-72VDC, 88-300VDC, 85-264VAC • TUV/UL 60950 safety approved to 85°C Warranty • 5 Year Warranty RuggedCom® RuggedBackbone™ 11 RX1501 Installation Guide Rev 104
Resumo do conteúdo contido na página número 12
2. RuggedBackbone™ Modules 2. RuggedBackbone™ Modules The RX1501 chassis provides seven module slots . Each slot accommodates a particular type of RuggedCom module. Figure 2.1, “RX1501 Chassis Slot Assignment” shows the module slots on the RX1501. Figure 2.1. RX1501 Chassis Slot Assignment The RX1501 chassis supports the following modules: LM1 through LM6 The RX1501 chassis supports up to six line module (LM) cards. For more information on line modules, see Section 2.2, “Line Modules (LM)”. All
Resumo do conteúdo contido na página número 13
2. RuggedBackbone™ Modules 2.1. Front Panel The RX1501 Front Panel is equipped with an RS232 serial console port for initial management functions, and a locally connected 10/100Base-T Ethernet port for system management out of band from the switch fabric. Figure 2.2. Front View - RX1501 Other Front Panel features include: • Utility USB port. • Power module indicator LED. • Line module indicator LEDs. • Alarm Indicator LED, which indicates system alarm status. • Lamp Test / Alarm Cutoff (LT/ACO)
Resumo do conteúdo contido na página número 14
2. RuggedBackbone™ Modules 2.2. Line Modules (LM) The RuggedBackbone™ RX1501 supports six line modules in slots LM1 through LM6 . Several types of line modules may be ordered, depending on the type, speed, and number of Ethernet ports required. The following illustrations show the typical port configurations and connectors available for RX1501 line modules. For complete information on the available line modules, refer to the RuggedBackbone™ RX1501 data sheet. Only one T1/E1 module may be used pe
Resumo do conteúdo contido na página número 15
2. RuggedBackbone™ Modules 2.2.3. SFP Modular Figure 2.12. FG5*: 2 × 1000LX/1000SX SFP Figure 2.13. FX5*: 4 × 100FX/100LX/100SX SFP Figure 2.14. 6FX50: 6 × 100FX SFP 2.2.4. WAN Figure 2.15. TC1: 1 × T1/E1 RJ45 Figure 2.16. E01: 1 × E1 BNC Figure 2.17. TC2: 2 × T1/E1 RJ45 Figure 2.18. E02: 2 × E1 BNC Figure 2.19. TC4: 4 × T1/E1 RJ45 2.2.5. Serial Figure 2.20. 6S01: 6 × Serial RJ45 2.2.6. Cellular Modem Figure 2.21. W11, W21, W32 Cellular Modem Figure 2.22. W12, W22 Cellular Modem RuggedCom® Rugge
Resumo do conteúdo contido na página número 16
2. RuggedBackbone™ Modules 2.2.7. DDS - Digital Data Services Figure 2.23. D02: 1 × DDS RJ45 2.2.8. APE - Appplication Processing Engine Figure 2.24. APE 1402 RuggedCom® RuggedBackbone™ 16 RX1501 Installation Guide Rev 104
Resumo do conteúdo contido na página número 17
2. RuggedBackbone™ Modules 2.3. Power Supply The RX1501 is equipped with a single power module. A single power module is capable of delivering a maximum of 42W, and accepts either AC or DC power at its input. Power modules may be ordered with a screw terminal block or with a pluggable terminal block. The screw terminal block features a safety cover which must be removed to make wiring connections, and must be replaced after wiring is complete. Power modules may be ordered as separate components.
Resumo do conteúdo contido na página número 18
3. Installation 3. Installation 3.1. Rack Mounting The RuggedBackbone™ RX1501 mounts to a standard 19" rack. Rack mounting brackets can be installed at the front or rear of the chassis. Placing the connectors at the rear allows all data and power cabling to be installed and connected on the same side of the rack. Remove the black pan head Phillips screws from the front or rear mounting locations. Position the rack mounting bracket, aligning the holes in the bracket with the screw holes on the ch
Resumo do conteúdo contido na página número 19
3. Installation Figure 3.3. RX1501Rack Mounting Dimensions – Top View Figure 3.4. RX1501Rack Mounting Dimensions – Rear View RuggedCom® RuggedBackbone™ 19 RX1501 Installation Guide Rev 104
Resumo do conteúdo contido na página número 20
3. Installation 3.1.2. Panel and DIN Rail Mounting The RuggedBackbone™ RX1501 features optional mounting brackets for panel and DIN rail mounting. The optional brackets attach to both sides of the appliance at the rear of the chassis. For panel mounting, the mounting bracket provides four mounting holes. For DIN rail mounting, the DIN adaptor mounts to a standard 1" DIN rail and is secured with a lock screw on each adaptor. To attach the mounting brackets, remove the black pan head Phillips scre