Resumo do conteúdo contido na página número 1
REJ10J0616-0400
H8/3048 Group, H8/3052 Group, H8/3062 Group,
H8/3067 Group, H8/3007 Group FP-100B/TFP-100B
User System Interface Cable for E6000 Emulator
HS3064BECH61H User’s Manual
HS3064BECH61HE
Renesas Microcomputer Development Environment System
H8 Family / H8/300H Series
Rev.4.00
Revision Date: Aug. 20, 2008
Resumo do conteúdo contido na página número 2
Resumo do conteúdo contido na página número 3
Notes regarding these materials 1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use. Renesas neither makes warranties or representations with respect to the accuracy or completeness of the information contained in this document nor grants any license to any intellectual property rights or any other rights of Renesas or any third party with respect to the information in this do
Resumo do conteúdo contido na página número 4
Resumo do conteúdo contido na página número 5
IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. � KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. User System Interface Cable: Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Renesas Technology Corp. excluding all subsidiary products. • User system inte
Resumo do conteúdo contido na página número 6
LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will repair or replace any user system interface cables determined to be defective in material and/or workmanship. User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole re
Resumo do conteúdo contido na página número 7
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state. The Warranty is Void in the Following Cases: Renesas shall have no liability or legal responsibility for any problems caused by misuse, abuse, misapplication, neglect,
Resumo do conteúdo contido na página número 8
SAFETY PAGE READ FIRST � READ this user's manual before using this user system interface cable. � KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates an immi
Resumo do conteúdo contido na página número 9
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the E6000 emulator and user system before connecting or disconnecting any CABLES or PARTS. 3. Always before c
Resumo do conteúdo contido na página número 10
VI
Resumo do conteúdo contido na página número 11
Preface Thank you for purchasing this user system interface cable (HS3064BECH61H) for the Renesas’ original microcomputers H8/3048 group, H8/3052 group, H8/3062 group, H8/3067 group, and H8/3007 group. The HS3064BECH61H is a user system interface cable that connects the H8/3048 group, H8/3052 group, H8/3062 group, H8/3067 group, H8/3007 group E6000 emulator (HS3064BEPI61H; hereinafter referred to as the emulator) to the IC socket for an FP-100B/TFP-100B package for the H8/3048 group, H8/3
Resumo do conteúdo contido na página número 12
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station .........................................3 2.2 Connecting User System Interface Cable to User System ................................................5 2.2.1 Installing IC Socket............................
Resumo do conteúdo contido na página número 13
Section 1 Configuration CAUTION Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100B/ TFP-100B package IC socket on the user system. Figure 1 shows the configuration of the HS3064BECH61H user system interface cable for the FP-100B/TFP-100B package. To emulator station CTS screws (M3 x 6 mm) for fastening the emulator station Cable body Screws (M2.6 x 12 mm) with flat washers Screws (M2.6 x 6 mm) (for fastening cable head) with flat w
Resumo do conteúdo contido na página número 14
Table 1 lists the HS3064BECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS3064BECH61H Components No. Component Quantity Remarks 1 Cable body 1 2 Cable head 1 3 IC socket 1 For the FP-100B/TFP-100B package 4 Socket cover 1 For installing an FP-100B/TFP-100B-packaged MCU 5 Screws (M2.6 x 12 mm) 4 For fastening cable head (with four flat washers) 6 Screws (M2.6 x 6 mm) 4 For installing an FP-100B/TFP-100B-packaged MCU (with four flat wash
Resumo do conteúdo contido na página número 15
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before c
Resumo do conteúdo contido na página número 16
2. After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket, and fasten the emulator station with two CTS screw (M3 x 6 mm) (figure 2). Emulator station Cable body connector CTS screws (M3 x 6 mm) User system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station 4 E6000
Resumo do conteúdo contido na página número 17
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cab
Resumo do conteúdo contido na página número 18
2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-100B/TFP-100B package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 3. 2.2.4 Fastening Cable Head CAUTION 1. Use a Philips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.294 N•m or less.
Resumo do conteúdo contido na página número 19
Fasten the user system interface cable head to the IC socket for an FP-100B/TFP-100B package on the user system with the four screws (M2.6 x 12 mm; with four flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Screws (M2.6 x 12 mm) with
Resumo do conteúdo contido na página número 20
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jigs. Remove jig Cable head User system Figure 4 Fastening Cable Body 8