Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
Resumo do conteúdo contido na página número 3
Preface Thank you for purchasing this user system interface cable (HS2338ECH61H) for the Renesas’s original microcomputer H8S/2338 series. The HS2338ECH61H is a user system interface cable that connects an H8S/2338 series E6000 emulator (HS2338EPI61H; hereinafter referred to as the emulator) to the IC socket for a QFP-144 package (package code: FP-144) for the H8S/2338 series MCU on the user system. i
Resumo do conteúdo contido na página número 4
Contents Section 1 Configuration...................................................................................1 Section 2 Connection Procedures....................................................................4 2.1 Connecting User System Interface Cable to Emulator Station .........................................4 2.2 Connecting User System Interface Cable to User System ................................................5 2.2.1 Installing IC Socket ..................................
Resumo do conteúdo contido na página número 5
Section 1 Configuration CAUTION Use an NQPACK144SD socket (manufactured by Tokyo Eletech Coporation) for the FP-144 package IC socket on the user system. Figure 1 shows the configuration of the HS2338ECH61H user system interface cable for the FP-144 package. 1
Resumo do conteúdo contido na página número 6
To emulator station Cable body Screws (M2 x 10 mm) (for fastening cable head) Screws (M2 x 6 mm) Socket cover Cable head IC socket User system Figure 1 HS2338ECH61H User System Interface Cable 2
Resumo do conteúdo contido na página número 7
Table 1 lists the HS2338ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS2338ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP-144 package 4 Socket cover 1 For installing an FP-144 packaged MCU 5 Screws (M2 x 10 mm) 4 For fastening cable head 6 Screws (M2 x 6 mm) 4 For installing an FP-144 packaged MCU 7 Guide pins (φ 1 mm) 3 For determining the IC socket location
Resumo do conteúdo contido na página número 8
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the
Resumo do conteúdo contido na página número 9
Emulator station Cable body User system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station 2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product o
Resumo do conteúdo contido na página número 10
2.2.1 Installing IC Socket 1. Confirming the location of IC socket CAUTION After confirming the location of pin 1 on the IC socket, apply epoxy resin adhesive to the end of the four projections at the bottom of the IC socket, and fasten it to the user system. Use the guide pins provided to determine where to install the IC socket, as shown in figure 3. Pin 1 Guide pins 4 projections to apply IC socket epoxy resin adhesive to (NQPACK144SD manufactured by Tokyo Eletech Corporation
Resumo do conteúdo contido na página número 11
2.2.2 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a FP-144 system interface cable head into the IC socket on the user system, as shown in figure 4. 2.2.3 Fastening Cable Head CAUTION 1. Use the screwdriver provided for tightening screws. 2. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becom
Resumo do conteúdo contido na página número 12
Fasten the user system interface cable head to the IC socket for an FP-144 package on the user system with the four screws (M2 x 10 mm) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Screws (M2 x 10 mm) Cable head IC socket Pin 1 (NQPACK144SD ma
Resumo do conteúdo contido na página número 13
2.2.4 Connecting Cable Body to Cable Head Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 5 Fastening Cable Body 9
Resumo do conteúdo contido na página número 14
2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-144 package (NQPACK144SD: manufactured by Tokyo Eletech Corporation). Note that the dimensions in figure 6 are somewhat different from those of the actual chip's mount pad. 23.00 ± 0.15 11.50 2.00 ±0.10 0.50 0.25 (max.) Unit: mm Tolerance: ±0.10 unless otherwise specified Figure 6 Recommended Dimensions fo
Resumo do conteúdo contido na página número 15
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Unit: mm Tolerance: –0.5 mm Figure 7 Dimensions for User System Interface Cable Head 11
Resumo do conteúdo contido na página número 16
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. Cable head IC socket (NQPACK144SD User system Unit: mm manufactured by Tolerance: –0.5 mm Tokyo Eletech Corporation) Figure 8 Resulting Dimensions after Connecting User System Interface Cable 12
Resumo do conteúdo contido na página número 17
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket
Resumo do conteúdo contido na página número 18
Screws (M2 x 6 mm) Socket cover MCU Pin 1 IC socket (NQPACK144SD manufactured by Tokyo Eleteck Corporation) User system Figure 9 Installing MCU to User System 14
Resumo do conteúdo contido na página número 19
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2338 series, turn on the emulator according to the procedures described in the E6000 Series Emulator User's Manual (HS2000EPI61HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins with the MEMORY_FILL command (emulator command). If an error is detected, recheck the soldered IC socket and the location of pin 1. 3. The emulator con
Resumo do conteúdo contido na página número 20
4. In the H8S/2338 series MCU, the interrupt signal pins can be selected by the register setting. To trace the interrupt signals in the E6000 emulator, select the interrupt signal pins by setting switch P5 on the user system interface cable as shown in table 2. Table 2 Switch P5 Setting IRPAS Bit Value Interrupt Signal Pin Pin No. P5 Setting IRQ4 40 0 IRQ5 34 Close between 2 and 3 (Initial value) IRQ6 33 (setting at shipment) IRQ7 32 IRQ4 105 1 IRQ5 106 Close between 1 and 2