Resumo do conteúdo contido na página número 1
H8S/2646 Series
FP-144
User System Interface Cable
(HS2646ECH61H)
for E6000 Emulator
User’s Manual
HS2646ECH61HE(B)
Resumo do conteúdo contido na página número 2
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
Resumo do conteúdo contido na página número 3
Preface Thank you for purchasing this user system interface cable (HS2646ECH61H) for the Renesas’s original microcomputer H8S/2646 series. The HS2646ECH61H is a user system interface cable that connects an H8S/2636 and H8S/2646 series E6000 emulator (HS2646EPI61H; hereinafter referred to as the emulator) to the IC socket for a FP-144 package for the H8S/2646 series MCU on the user system. i
Resumo do conteúdo contido na página número 4
Contents Section 1 Configuration ......................................................................................1 Section 2 Connection Procedures .......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station .........................................3 2.2 Connecting User System Interface Cable to User System ................................................5 2.2.1 Installing IC Socket ........................
Resumo do conteúdo contido na página número 5
Section 1 Configuration CAUTION Use an NQPACK144SD socket (manufactured by Tokyo Eletech Corporation) for the FP-144 package IC socket on the user system. Figure 1 shows the configuration of the HS2646ECH61H user system interface cable for the FP-144 package. Figure 1 HS2646ECH61H User System Interface Cable 1
Resumo do conteúdo contido na página número 6
Table 1 lists the HS2646ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS2646ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP-144 package 4 Socket cover 1 For installing an FP-144 packaged MCU 5 Screws (M2 x 10 mm) 4 For fastening cable head 6 Screws (M2 x 6 mm) 4 For installing an FP-144 packaged MCU 7 Guide pins (φ 1 mm) 3 For determining the IC socket location 8 Screwd
Resumo do conteúdo contido na página número 7
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before con
Resumo do conteúdo contido na página número 8
Emulator station Cable body connector User system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station 4 E6000
Resumo do conteúdo contido na página número 9
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the c
Resumo do conteúdo contido na página número 10
Guide pins Pin 1 4 projections to apply epoxy resin adhesive to IC socket (NQPACK144SD manufactured by Tokyo Eletech Corporation) Bottom view of IC soket User system Figure 3 Location Setting of IC Socket 2. Solder the IC socket for a FP-144 package to the user system. CAUTION Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets. (Use slightly more solder than the MCU.) 2.2.2 Inserting Cable Head CAUTION Check the l
Resumo do conteúdo contido na página número 11
2.2.3 Fastening Cable Head CAUTION 1. Use a Philips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC sock
Resumo do conteúdo contido na página número 12
Fasten the user system interface cable head to the IC socket for an FP-144 package on the user system with the four screws (M2 x 10 mm) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Screws (M2 x 10mm) Cable head Pin 1 IC socket (NQPACK144SD manu
Resumo do conteúdo contido na página número 13
2.2.4 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 5 Fastening Cable Body 9
Resumo do conteúdo contido na página número 14
2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-144 package (NQPACK144SD: manufactured by Tokyo Eletech Corporation). Note that the dimensions in figure 6 are somewhat different from those of the actual chip's mount pad. 23.00 ± 0.15 11.50 2.00 ±0.10 0.50 0.25 (max.) Unit: mm Tolerance: ±0.10 unless otherwise specified Figure 6 Recommended Dimensions fo
Resumo do conteúdo contido na página número 15
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Figure 7 Dimensions for User System Interface Cable Head 11
Resumo do conteúdo contido na página número 16
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. Figure 8 Resulting Dimensions after Connecting User System Interface Cable 12
Resumo do conteúdo contido na página número 17
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break
Resumo do conteúdo contido na página número 18
Screws (M2 x 6 mm) Socket cover MCU Pin 1 IC socket (NQPACK144SD manufactured by Tokyo Eletech Corporation) User system Figure 9 Installing MCU to User System 14
Resumo do conteúdo contido na página número 19
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2646 series, turn on the emulator according to the procedures described in the E6000 Series Emulator User's Manual (HS2000EPI61HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins with the MEMORY_FILL command (emulator command). If an error is detected, recheck the soldered IC socket and the location of pin 1. 3. The emulator con
Resumo do conteúdo contido na página número 20
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifically designed for the HS2646EPI61H emulator. Do not use this cable with any other emulator station. 4. To prevent breaking of wires in the ca