Har dwar e Maint enance Manual
Machine T ypes: 6531, 6532, 6533, and 6534.
Resumo do conteúdo contido na página número 2
Resumo do conteúdo contido na página número 3
Har dwar e Maint enance Manual Machine T ypes: 6531, 6532, 6533, and 6534.
Resumo do conteúdo contido na página número 4
Not e: Befor e using this information and the pr oduct it suppor ts, r ead the gener al information in Appendix A “Notices” on page 221 and the W arr anty and Suppor t Information document on the ThinkSer ver Documentation DVD . Thir d Edition (Sept ember 2010) © Copyright L enovo 2009, 2010. LENO V O pr oducts, data, comput er softwar e, and ser vices have been developed e x clusively at privat e e xpense and ar e sold t o governmental entities as commer cial it ems as defined by 48 C.F .R. 2.1
Resumo do conteúdo contido na página número 5
Contents Chapt er 1. About this manual . . . . . 1 Softwar e pr oblems . . . . . . . . . . . 60 Impor tant Safety Information . . . . . . . . . . 1 Universal Serial Bus (USB) por t pr oblems . . 61 Safety stat ements . . . . . . . . . . . . . . 2 V ideo pr oblems . . . . . . . . . . . . 61 Impor tant information about r eplacing RoHS Err or LEDs . . . . . . . . . . . . . . . . 61 compliant FRUs . . . . . . . . . . . . . . . 5 P ower -supply LEDs . . . . . . . . . . . . . 63 T urkish stat ement o
Resumo do conteúdo contido na página número 6
Replacing a memor y module (DIMM) . . . . . . 122 Installing the SAS backplane (2.5-inch drives) . . . . . . . . . . . . . . . . 155 Suppor t ed memor y types . . . . . . . . 122 Replacing the PCI riser -car d assembly . . . . . 156 Removing a memor y module . . . . . . . 125 Removing the riser -car d assembly . . . . . 156 Installing a memor y module . . . . . . . . 125 Installing the riser -car d assembly . . . . . 157 Replacing har d disk drives . . . . . . . . . . 126 Replacing an IBM Ser ve
Resumo do conteúdo contido na página número 7
Befor e you use the EasyS tar tup DVD . . . . 208 T r ademarks . . . . . . . . . . . . . . . . 222 EasyS tar tup over view . . . . . . . . . . 208 Impor tant not es . . . . . . . . . . . . . . 222 Installing your oper ating syst em without using P r oduct r ecycling and disposal . . . . . . . . 223 EasyS tar tup . . . . . . . . . . . . . . 210 Compliance with Republic of T urk ey Dir ective on Updating the firmwar e . . . . . . . . . . . . 211 the Restriction of Hazar dous Substances . . . . 224
Resumo do conteúdo contido na página número 8
viii Har dwar e Maint enance Manual
Resumo do conteúdo contido na página número 9
Chapt er 1. About this manual This Har dwar e Maint enance Manual contains information t o help you solve pr oblems that might occur in your ser ver . It describes the diagnostic t ools that come with the ser ver , err or codes and suggest ed actions, and instructions for r eplacing failing components. Replaceable components ar e of thr ee types: • Self-ser vice cust omer r eplaceable unit (CRU): Replacement of self-ser vice CRUs is your r esponsibility . If L enovo® installs a self-ser vice CRU
Resumo do conteúdo contido na página número 10
Safety stat ements Impor tant: Each caution and danger stat ement in this document is labeled with a number . This number is used t o cr oss r efer ence an English-language caution or danger stat ement with tr anslat ed versions of the caution or danger stat ement in the Safety Information document. F or e xample, if a caution stat ement is labeled "S tat ement 1," tr anslations for that caution stat ement ar e in the Safety Information document under "S tat ement 1." Be sur e t o r ead all caut
Resumo do conteúdo contido na página número 11
• Thr ow or immerse int o wat er • Heat t o mor e than 100°C (212°F) • Repair or disassemble Dispose of the batt er y as r equir ed by local or dinances or r egulations. S tat ement 3 C A UTION: When laser pr oducts (such as CD-ROMs, DVD drives, fiber optic devices, or tr ansmitt ers) ar e installed, not e the following: • Do not r emove the covers. Removing the covers of the laser pr oduct could r esult in e xposur e t o hazar dous laser r adiation. Ther e ar e no ser viceable par ts inside the
Resumo do conteúdo contido na página número 12
S tat ement 5 C A UTION: The power contr ol butt on on the device and the power switch on the power supply do not turn off the electrical curr ent supplied t o the device. The device also might have mor e than one power cor d. T o r emove all electrical curr ent fr om the device, ensur e that all power cor ds ar e disconnect ed fr om the power sour ce. S tat ement 8 C A UTION: Never r emove the cover on a power supply or any par t that has the following label attached. Hazar dous voltage, curr e
Resumo do conteúdo contido na página número 13
Impor tant information about r eplacing RoHS compliant FRUs RoHS, The Restriction of Hazar dous Substances in Electrical and Electr onic Equipment Dir ective (2002/95/EC) is a Eur opean Union legal r equir ement affecting the global electr onics industr y . RoHS r equir ements must be implement ed on L enovo pr oducts placed on the mark et and sold in the Eur opean Union aft er June 2006. P r oducts on the mark et befor e June 2006 ar e not r equir ed t o have RoHS compliant par ts. If the par t
Resumo do conteúdo contido na página número 14
6 Har dwar e Maint enance Manual
Resumo do conteúdo contido na página número 15
Chapt er 2. Gener al information This chapt er pr ovides gener al information that applies t o all machine types suppor t ed by this publication. F eatur es and t echnologies The ser ver uses the following featur es and t echnologies: • UEFI-compliant ser ver firmwar e UEFI r eplaces the basic input/output syst em (BIOS) and defines a standar d int er face between the oper ating syst em, platform firmwar e, and e xt ernal devices. The ser ver design combines the UEFI capabilities and featur es w
Resumo do conteúdo contido na página número 16
• Lar ge syst em-memor y capability The memor y bus suppor ts up t o 24 GB of memor y when r egist er ed DIMMs ar e installed. The ser ver suppor ts up t o 8 GB if unbuffer ed DIMMs ar e installed. The memor y contr oller suppor ts err or corr ecting code (ECC) for up t o six industr y-standar d PC3-8500 or PC3-10600R-999, 1066 and 1333 MHz, DDR3 (thir d-gener ation double-data-r at e), r egist er ed or unbuffer ed, synchr onous dynamic r andom access memor y (SDRAM) dual inline memor y modules
Resumo do conteúdo contido na página número 17
– E vent logs for RAID contr ollers and ser vice pr ocessors The diagnostics pr ogr ams cr eat e a mer ged log that includes events fr om all collect ed logs. The information is collect ed int o a file that you can send t o the L enovo t echnical suppor t t eam t o help diagnose a pr oblem. Additionally, you can view the information locally thr ough a gener at ed t e xt r epor t file. Y ou can also copy the log t o a r emovable medium and view the HTML log fr om a W eb br owser . F or additional
Resumo do conteúdo contido na página número 18
T able 1. F eatur es and specifications Micr opr ocessor: SA T A optical drives: Int egr at ed functions: • Int egr at ed management module • Suppor ts one Int el® quad-cor e • Ultr aSlim DVD-ROM combo (IMM), which pr ovides ser vice (Xeon 3400 series) or dual-cor e (optional) pr ocessor contr ol and monit oring (Celer on G1101, P entium G6950, • Multi-burner (optional) functions, video contr oller , and or cor e i3 series) pr ocessor (when the optional vir tual media with the Ibe xP eak 3420 ch
Resumo do conteúdo contido na página número 19
T able 1. F eatur es and specifications (continued) RAID contr ollers: V ideo contr oller (int egr at ed int o 1. P ower consumption and heat IMM): output var y depending on the • An IBM Ser veRAID-BR10il • Matr o x G200 number and type of optional SAS/SA T A Contr oller that pr ovides featur es installed and the • SVGA compatible video contr oller RAID levels 0, 1, and 1E (comes • DDR2 128 MB SDRAM video power -management optional standar d on some hot-swap SAS memor y featur es in use. and hot
Resumo do conteúdo contido na página número 20
EasyS tar tup The ThinkSer ver EasyS tar tup pr ogr am simplifies the pr ocess of configuring your RAID contr ollers and installing suppor t ed ® Micr osoft ® W indows and Linux oper ating syst ems and device drivers on your ser ver . The EasyS tar tup pr ogr am is pr ovided with your ser ver on DVD . The DVD is self star ting (bootable). The User Guide for the EasyS tar tup pr ogr am is on the DVD and can be accessed dir ectly fr om the pr ogr am int er face. F or additional information, see “U