Resumo do conteúdo contido na página número 1
AN706-00044-1v0-E
32-BIT MICROCONTROLLER
MB9B100A/MB9B300A/MB9B400A/MB9B500A Series
FM3 family inverter solution
GUI User Manual
TM
ARM and Cortex-M3 are the trademarks of ARM Limited in the EU and other countries.
Resumo do conteúdo contido na página número 2
AN706-00044-1v0-E All Rights Reserved. The contents of this document are subject to change without notice. Customers are advised to consult with FUJITSU sales representatives before ordering. The information, such as descriptions of function and application circuit examples, in this document are presented solely for the purpose of reference to show examples of operations and uses of Fujitsu semiconductor device; Fujitsu does not warrant proper operation of the device with respect to use
Resumo do conteúdo contido na página número 3
AN706-00044-1v0-E Revision History Rev Date Remark 1.0 Jul. 14, 2011 First Edition 2
Resumo do conteúdo contido na página número 4
AN706-00044-1v0-E Table of Contents Revision History....................................................................................................................2 Table of Contents..................................................................................................................3 1 Introduction....................................................................................................................4 2 System requirements.................................
Resumo do conteúdo contido na página número 5
AN706-00044-1v0-E 1 Introduction This user manual describes how to use FUJITSU’S FM3 Inverter Platform GUI. In Chapter 2, it explains system requirements for the GUI software. In Chapter 3, it explains how to install the GUI software. In Chapter 4, it explains how to install the communication driver (FTDI). In Chapter 5, it explains how to use the GUI. 4
Resumo do conteúdo contido na página número 6
AN706-00044-1v0-E 2 System requirements The GUI software supported environment on PC 2.1 Supported Operating Systems: Windows Server 2003, Windows Server 2008, Windows Vista, Windows XP, Windows 7 1. Microsoft Windows XP Service Pack 2 or Service Pack 3 Minimum of 192 MB of RAM (384 MB preferred) At least a 1 GHz processor (1.6 GHz preferred) 2. Microsoft Windows Vista or Windows Vista SP1 Minimum of 768 MB of RAM (1 GB preferred) At least a 1.6 GHz processor (2.2 GHz preferr
Resumo do conteúdo contido na página número 7
AN706-00044-1v0-E 3 Install GUI Install the GUI software in your PC This FUJITSU’S FM3 Inverter Platform GUI is given by compressed file, please copy and unzip the “FUJITSU’S FM3 Inverter platform GUI.zip” file to your PC. Then, you will find 10 files in the “FUJITSU’S FM3 Inverter platform GUI” folder. Table 3-1: GUI files File name Remarks 1 ARMInverterPlatform.exe the Software Executable file 2 Electromotor_Ch.xsd 3 Electromotor_En.xsd Parameter type file 4 Syst
Resumo do conteúdo contido na página número 8
AN706-00044-1v0-E 4 Simply install steps about the communication Driver A simply install steps for the FTDI. 4.1 To install FTDI driver in Windows XP Simply install steps: 1. Connect the FTDI device (board) to a USB port on the PC. 2. New Hardware Wizard will launch. 3. Select "Install from a list or specific location (Advanced)". 4. Select "Search for the best driver in these locations" and enter the file path in the combo-box. 5. Install the “ftd2xxx.dll”file in the PC. 6. The sam
Resumo do conteúdo contido na página número 9
AN706-00044-1v0-E 5 How to use the GUI Introduce the GUI software 5.1 Overview This GUI use to cooperate with the FUJITSU’S FM3 inverter platform, customer can use this GUI to: 1. Real-time control the motor and PFC module function; 2. Real-time setting the motor functions and parameters; 3. Real-time observation of motor running state, used variables and current waveform shape. 4. Real-time observation of system information, and so on. It’s means that the GUI is ordered to help c
Resumo do conteúdo contido na página número 10
AN706-00044-1v0-E 5.3 GUI Startup Open the folder; double click the “ARMInverterPlatform.exe” to run the software, as Figure 5.2. Figure 5-2: GUI files 9
Resumo do conteúdo contido na página número 11
AN706-00044-1v0-E 5.4 GUI software windows’ name and function 5.4.1 Inverter Platform software introduce. - Name: Platform - Function: language setting, contain all function windows, and so on. Figure 5-3: Inverter Platform 10
Resumo do conteúdo contido na página número 12
AN706-00044-1v0-E 5.4.2 Main window - Name : Main window - Function: connect control, start/stop control, function/parameter setting, Constant/variable observation, language setting, and current state. 1 2 4 3 5 6 7 8 9 10 Figure 5-4: main window Table 5-1: main window function Name of button Specification 1 Connect Init the FTDI and Connect with MCU 2 PFC start-stop control Operate PFC module function start / stop 3 Compressor st
Resumo do conteúdo contido na página número 13
AN706-00044-1v0-E Observe system state, motor state, motor parameter, and so on. 6 Constant observation If the button is pushed, the constant window opens. (See Chapter 4.4.6) Observe measure value with variable. 7 Variable observation If the button is pushed, the variable window opens. (See Chapter4.4.5) Observe measure value with wave. 8 Graphic If the button is pushed, Figure4-3 of the graphic window opens. (See Chapter 4.4.4) 9 Language setting Set system language
Resumo do conteúdo contido na página número 14
AN706-00044-1v0-E 5.4.3 Function/parameter settings window - Name : function/parameter settings window - Function: motor selection, motor function setting and comeback default, motor parameter setting and comeback default, save config file, load config file. 1 2 3 6 4 5 Figure 5-5: setting window 13
Resumo do conteúdo contido na página número 15
AN706-00044-1v0-E Table 5-2: setting window function Name of area Specification 1 Motor selection Select which motor need to set, compressor / fan 2 Motor function set Function set 3 Motor parameter set Parameter set 4 Parameter type selection Selection motor parameter type 5 Config file save and load Save and load config file 6 Set and default button Set/default the parameter and function to hardware - Notice: - The hardware cannot be mounted Fan motor. So the fu
Resumo do conteúdo contido na página número 16
AN706-00044-1v0-E - How to operation of “Function/parameter settings window” Open this window and you can see the default parameters values. If you want to change the value, after connecting to the board, (1) Select the parameter (2) Change the value directly (and the changed value becomes red) (3) Push “set” button on the right. (4) Be sent the value to MCU and set it. Selected and changed value Set button for parameter setting If you want to change the default val
Resumo do conteúdo contido na página número 17
AN706-00044-1v0-E If you want to save the setting value, after connecting to the board and setting some parameters, (1) Push “saveconfig” button under the window. (2) Select the saving folder and name the .aip file (3) Push save button and the configuration file is saved. If you want to load the configuration file, after connecting to the board, (1) Push “loadconfig” button under the window. (2) Select the loaded .aip file (3) Push open button and the configuration f
Resumo do conteúdo contido na página número 18
AN706-00044-1v0-E 5.4.4 Signal selection window - Name : select signal window - Function: signal page selection, signal selection, signal type select, selected signal shown and some button 1 2 3 5 4 Figure 5-6: select signal window 17
Resumo do conteúdo contido na página número 19
AN706-00044-1v0-E Table 5-3: select signal function Name of area Specification 1 Signal page selection Select the signal page Select the signal 2 Available signals (most 4 signals in wave, most 10signals in variable ) 3 Selected signal type Select the signal type 4 selected signals Show the selected signals Set / cancel. If the button is selected, 5 Operation button Figure4.4-5 of the graphic window opens. (See Chapter 4.4.4) - Notice: - This window can sel
Resumo do conteúdo contido na página número 20
AN706-00044-1v0-E 5.4.5 Graphic window - Name : wave observer window - Function: window name set, real-time drawing the wave, showing the selection signal name, setting the wave station, run/pause set, save/load wave data, current state. 1 4 2 5 6 3 7 Figure 5-7: wave observer window 19