Resumo do conteúdo contido na página número 1
®
53-1002599-01
19 September 2012
Brocade ICX 6650
Hardware Installation Guide
Resumo do conteúdo contido na página número 2
Copyright © 2012 Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, Brocade One, the B-wing symbol, DCX, Fabric OS, ICX, MLX, MyBrocade, SAN Health, VCS, and VDX are registered trademarks, and AnyIO, HyperEdge, NET Health, OpenScript, and The Effortless Network are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of their respective ow
Resumo do conteúdo contido na página número 3
Contents About This Document Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . . xi Brocade ICX 6650 slot and Ethernet port numbering . . . . . . . . . . . .xi How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii Text form
Resumo do conteúdo contido na página número 4
Installation precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 General precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Lifting precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Power precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Installing the device in a rack or cabinet. . . . . . . . . . . . . . . . . . . . . .12 2-Post rack mount installation . .
Resumo do conteúdo contido na página número 5
Hardware maintenance schedule . . . . . . . . . . . . . . . . . . . . . . . . . . .38 Replacing a copper or fiber optic module . . . . . . . . . . . . . . . . . . . . .39 Removing a copper or fiber optic module . . . . . . . . . . . . . . . . .39 Cabling a fiber optic module . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 Cleaning the fiber optic connectors . . . . . . . . . . . . . . . . . . . . . .40 FRU removal and replacement procedures. . . . . . . . . . . . . . . . . . . .40 Repl
Resumo do conteúdo contido na página número 6
Index vi Brocade ICX 6650 Hardware Installation Guide 53-1002599-01
Resumo do conteúdo contido na página número 7
Figures Figure 1 Front view of the Brocade ICX 6650 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Figure 2 Back view of the Brocade ICX 6650. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Figure 3 Brocade ICX 6650 front-panel ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 4 Brocade ICX 6650 rear-panel ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 5 QSFP+ to 4 SFP
Resumo do conteúdo contido na página número 8
2 Brocade ICX 6650 Installation Guide 53-1002599-01
Resumo do conteúdo contido na página número 9
Tables Table 1 Installation tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Table 2 Power supply status LED behavior, description, and required actions. . . . . . . . 42 Table 3 Physical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Table 4 Environmental requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Table 5 Power stat
Resumo do conteúdo contido na página número 10
4 Brocade ICX 6650 Ethernet Installation Guide 53-1002599-01
Resumo do conteúdo contido na página número 11
About This Document The Brocade ICX 6650 is a ToR (Top of Rack) Ethernet switch for campus LAN and classic Ethernet data center environments. Audience This document is designed for system administrators with a working knowledge of Layer 2 and Layer 3 switching and routing. If you are using a Brocade Layer 3 Switch, you should be familiar with the following protocols if applicable to your network: IP, RIP, OSPF, BGP, ISIS, PIM, and VRRP. Supported hardware and software This document is specifi
Resumo do conteúdo contido na página número 12
Brocade ICX 6650 slot and Ethernet port numbering • Slot 2 is located on the back of the ICX 6650 device and contains ports 1 through 3 on the top row and port 4 on the bottom row. These ports are 2x40 GbE QSFP+. Refer to the following figure. Slot 2 Slot 2 Slot 3 • Slot 3 is located on the back of the ICX 6650 device and contains ports 1 through 8. These ports are 4 x 10 GbE breakout ports and require the use of a breakout cable. Refer to the previous figure. How this document is organized
Resumo do conteúdo contido na página número 13
Brocade ICX 6650 slot and Ethernet port numbering Document conventions This section describes text formatting conventions and important notice formats used in this document. Text formatting The narrative-text formatting conventions that are used are as follows: bold text Identifies command names Identifies the names of user-manipulated GUI elements Identifies keywords and operands Identifies text to enter at the GUI or CLI italic text Provides emphasis Identifies variables Identifies paths and
Resumo do conteúdo contido na página número 14
Brocade ICX 6650 slot and Ethernet port numbering ATTENTION An Attention statement indicates potential damage to hardware or data. CAUTION A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware, firmware, software, or data. DANGER A Danger statement indicates conditions or situations that can be potentially lethal or extremely hazardous to you. Safety labels are also attached directly to products to warn of these conditions or situati
Resumo do conteúdo contido na página número 15
Brocade ICX 6650 slot and Ethernet port numbering • Brocade ICX 6650 Diagnostic Reference • Unified IP MIB Reference • Ports-on-Demand Licensing for the Brocade ICX 6650 The latest versions of these guides are posted at http://www.myBrocade.com/ethernetproducts. Additional information This section lists additional Brocade and industry-specific documentation that you might find helpful. Brocade resources To get up-to-the-minute information, go to http://www.myBrocade.com to register at no cost
Resumo do conteúdo contido na página número 16
Brocade ICX 6650 slot and Ethernet port numbering xvi Brocade ICX 6650 Hardware Installation Guide 53-1002599-01
Resumo do conteúdo contido na página número 17
Chapter Brocade ICX 6650 Overview 1 In this chapter •Brocade ICX 6650 overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 •Views of the Brocade ICX 6650 switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 •Ports-on-Demand licensing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 •Brocade ICX 6650 slot and Ethernet port numbering . . . . . . . . . . . . . . . . . . 4 •Supported transceivers and cables . . . . .
Resumo do conteúdo contido na página número 18
1 Views of the Brocade ICX 6650 switch Views of the Brocade ICX 6650 switch Figure 1 shows the front view of the Brocade ICX 6650 switch. FIGURE 1 Front view of the Brocade ICX 6650 12 3 4 5 6 7 8 9 10 1 Push button reset 6 Air Intake/Exhaust 2 PSU1 and PSU2 status LEDs 7 Ports 1/1 through 1/32 3 DIAG/MS status LEDs 8 Ports 1/33 through 1/40 4 1x40 GbE QSFP rear port status/activity LEDs 9 Ports 1/41 through 1/48 5 4x10 GbE QSFP-to-SFP breakout port 10 Ports 1/49 through 1/56 status/activity LE
Resumo do conteúdo contido na página número 19
Ports-on-Demand licensing 1 Ports-on-Demand licensing The Brocade ICX 6650 device features Ports-on-Demand licensing. With Ports-on-Demand licensing, software features do not require licenses and you can add port licenses as needed. A fully populated device supports 56 front-panel, dual-speed 1/10 GbE SFP+ ports, 4 rear panel 40 GbE QSFP+ ports, and 2 rear panel 4x10 GbE QSFP+ breakout ports. You can purchase and install Ports-on-Demand licenses in blocks of eight dual-speed 1/10 GbE SFP+ fro
Resumo do conteúdo contido na página número 20
1 Brocade ICX 6650 slot and Ethernet port numbering The breakout ports support either: • Direct-attached copper breakout cables QSPF+ to 4 SFP+ (Part number 40G-QSFP-4SFP-C-/0101/0301/0501) • Breakout capable SR4 QSPF+ optical transceiver (Part number 40G-QSFP-SR4-INT) NOTE You can add a ICX6650-2P40G-LIC-POD license to any configuration. For example you can add a ICX6650-2P40G-LIC-POD license to a base 32 port configuration. No trial licenses are available with Ports-on-Demand licensing. Broc