Resumo do conteúdo contido na página número 1
ProxyBlocker
QUICK START
GUIDE
Model: ProxyBlocker
MSA-004-005
Release: 1.0.00 / Updated: 02.11.08
®
Resumo do conteúdo contido na página número 2
8e 6 Pxyro Bockerl Quick Sartt Guide © 2008 8e6 Technologies. All rights reserved. This document may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any elec- tronic medium or machine readable form without prior written consent from 8e6 Technologies. Every effort has been made to ensure the accuracy of this document. However, 8e6 Technologies makes no war- ranties with respect to this documentation and disclaims any implied warranties of merchantability a
Resumo do conteúdo contido na página número 3
Contents 8e 6 Proxy BloCker IC ntrodu tIon ...............................................................1 About this Document ....................................................................................................................2 Conventions Used in this Document ...........................................................................................2 s vIC er e ItInforma on ..................................................................................3 PIrel Im ynar s P e
Resumo do conteúdo contido na página número 4
iv 8e 6 P roxy Blocker Q uick S tart G uide
Resumo do conteúdo contido na página número 5
8e 6 Proxy BC lo ker IC ntrodu tIon Thank you for choosing to evaluate the 8e6 Technologies ProxyBlocker. The Proxy- Blocker offers a solution for organizations using an Internet filtering product other than 8e6’s R3000 Enterprise Filter. 8e6 ProxyBlocker tracks each user’s online activity of Web-based proxies and anonymizers, and can be configured to block specific Web sites or service ports, thereby protecting your organization against lost productivity, network bandwidth issues, and possi
Resumo do conteúdo contido na página número 6
About this Document This document is divided into the following sections: • Introduction - This section is comprised of an overview of the ProxyBlocker product and how to use this document • Service Information - This section provides 8e6 Technologies contact information • Preliminary Setup Procedures - This section includes instructions on how to physi- cally set up the ProxyBlocker in your network environment • Install the Server - This section explains how to configure the ProxyBlocker for
Resumo do conteúdo contido na página número 7
s IC ver e IItnforma on The user should not attempt any maintenance or service on the unit beyond the proce- dures outlined in this document. Any initial hardware setup problem that cannot be resolved at your internal organiza- tion should be referred to an 8e6 Technologies solutions engineer or technical support representative. 8e6 Corporate Headquarters (USA) Local : 714.282.6111 Domestic US : 1.888.786.7999 International : +1.714.282.6111 8e6 Taiwan Taipei Local : 2397-0300 Domestic
Resumo do conteúdo contido na página número 8
PIrel Im ynar s P etu ProCedures Unpack the Unit from the Carton Inspect the packaging container for evidence of mishandling during transit. If the packag- ing container is damaged, photograph it for reference. Carefully unpack the unit from the carton and verify that all accessories are included. Save all packing materials in the event that the unit needs to be returned to 8e6 Tech- nologies. The carton should contain the following items: • 1 ProxyBlocker unit • 1 AC Power Cord • 1 Serial Por
Resumo do conteúdo contido na página número 9
Select a Site for the Server The server operates reliably within normal office environmental limits. Select a site that meets the following criteria: • Clean and relatively free of excess dust. • Well-ventilated and away from sources of heat, with the ventilating openings on the server kept free of obstructions. • Away from sources of vibration or physical shock. • Isolated from strong electromagnetic fields and noise caused by electrical devices such as elevators, copy machines, air conditio
Resumo do conteúdo contido na página número 10
Rack Mount the Server Rack Setup Precautions Warning: Before rack mounting the server, the physical environment should be set up to safely ac- commodate the server. Be sure that: • The weight of all units in the rack is evenly distributed. Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. • The rack will not tip over when the server is mounted, even when the unit is fully extended from the rack. • For a single rac
Resumo do conteúdo contido na página número 11
Rack Mount Instructions Optional: Install the Chassis Rails NOTE: If your chassis does not come with chassis rails, please follow the procedure listed on the last page of this sub-section to install the unit directly into the rack. CAUTION: Please make sure that the chassis covers and chassis rails are installed on the chassis before you install the chassis into the rack. To avoid personal injury and property damage, please carefully follow all the safety steps listed below: Before installi
Resumo do conteúdo contido na página número 12
3. Locate the three holes on each side of the chassis and locate the three correspond- ing holes on each of the inner rail. 4. Attach an inner rail to each side of the chassis and secure the inner rail to the chas- sis by inserting three Type G screws through the holes on each side of the chassis and the inner rail. (See the diagram below for a description of the Type G screw.) 5. Repeat the above steps to install the other rail on the chassis. 8 8e 6 P roxy Blocker Q uick S tart G uide
Resumo do conteúdo contido na página número 13
Optional: Install the Traditional UP Racks After you have installed the inner rails on the chassis, you are ready to install the outer rails of rail assemblies to the rack. NOTE: The rails are designed to fit in the racks with the depth of 28” to 33”. • Determine the placement of each component in the rack before you install the rails. • Install the heaviest server components on the bottom of the rack first, and then work up. 1. In the package, locate a pair of front (short) and rear (long) b
Resumo do conteúdo contido na página número 14
7. Slide the chassis into the rack as shown below. NOTE: The chassis may not slide into the rack smoothly or easily when installed the first time. Some adjustment to the slide assemblies might be needed for easy installation. 8. You will need to release the safety taps on both sides of the chassis in order to com- pletely remove the chassis out of the rack. 0 8e 6 P roxy Blocker Q uick S tart G uide
Resumo do conteúdo contido na página número 15
Optional: Install the Open Racks After you have installed the inner rails on the chassis, you are ready to install the outer rails of rail assemblies to the rack. NOTE: The rails are designed to fit in the racks with the depth of 28” to 33”. • Determine the placement of each component in the rack before you install the rails. • Install the heaviest server components on the bottom of the rack first, and then work up. 1. In the package, locate a pair of front (short) and rear (long) brackets. P
Resumo do conteúdo contido na página número 16
3. Attach the front (short) bracket to the front end of the rack, and secure it to the rack with two Type H screws and Type I washers as shown below. (See the previous page for descriptions of Type H and Type I hardware components.) 4. Attach the rear (long) bracket to the rear end of the rack, and secure it to the rack with two Type H screws and Type I washers as shown below. Repeat the same steps to install the other outer rail to the other side of rack. 5. Measure the depth of your rack a
Resumo do conteúdo contido na página número 17
6. Slide the inner rails which are attached to the chassis into the outer rails on the rack. 8e 6P roxy Blocker Q uick S tart G uide
Resumo do conteúdo contido na página número 18
Install the Chassis into the Rack CAUTION: Before installing the chassis into the rack: • Make sure that the rack is securely anchored onto an unmovable surface or structure before installing the chassis into the rack. • Unplug power cord(s) of the rack before installing the chassis into the rack. • Make sure that the system is adequately supported. Make sure that all the components are securely fastened to the chassis to prevent components fall- ing off from the chassis. • The rack assembly s
Resumo do conteúdo contido na página número 19
Check the Power Supply This server is equipped with a universal power supply that handles 100-240 V, 50/60 Hz. A standard power cord interface (IEC 950) facilitates power plugs that are suitable for most European, North American, and Pacific Rim countries. Power Supply Precautions Warning: • Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep the server operating in case of a power failure. • In geographic regions that are su
Resumo do conteúdo contido na página número 20
General Safety Information Server Operation and Maintenance Precautions Warning: Observe the following safety precautions during server operation and maintenance: WARNING: If the server is used in a manner not specified by the manufacturer, the protection provided by the server may be impaired. WARNING: 8e6 Technologies is not responsible for regulatory compliance of any server that has been modified. Altering the server’s enclosure in any way other than the installation operations specified