(Supplement to the FieldServer Instruction Manual)
FS-8700-130 Notifier NCA2-NFS2-3030
APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after January 2009
Driver Version: 1.02
Document Revision: 1
Resumo do conteúdo contido na página número 2
FS-8700-130 Notifier NCA2/NFS-3030 Manual Table of Contents TABLE OF CONTENTS 1 Notifier NCA2/NFS2-3030 Description ............................................................................................................ 3 2 Driver Scope of Supply ................................................................................................................................... 3 2.1 Supplied by FieldServer Technologies for this driver .................................................
Resumo do conteúdo contido na página número 3
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 3 of 22 1 NOTIFIER NCA2/NFS2-3030 DESCRIPTION The NCA2/NFS2-3030 Serial driver allows the FieldServer to record data from Notifier NCA2 or NFS2-3030 panels over RS-232 as per NFS2-3030/NCA-2 EIA-232 Protocol & Data Formats 53219 Rev A 1/3/2008. There is no active polling by this driver; the communications are one-way through the panel's printer or CRT port. The FieldServer acts as a Client; receives messages and records the status of a
Resumo do conteúdo contido na página número 4
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 4 of 22 3 HARDWARE CONNECTIONS The FieldServer is connected to the Notifier NCA2/NFS2-3030 Fire Panel as shown in the following connection drawing. Configure the Notifier Panel according to manufacturer’s instructions. RJ45 Notifier NCA2/NFS2-3030 Rx (Brown) Com (Blue/White) Tx (Orange/White) Connection to TB5 Printer Port. Printer CRT TB5 PTX PRX REF CTX CRX REF FieldServer Part # 8917-16 Pigtail for RJ45 Port Connect to one of the
Resumo do conteúdo contido na página número 5
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 5 of 22 3.1 Hardware Connection Tips / Hints • The FieldServer should preferably be connected to the TB5 Printer port. It is theoretically possible to connect to the TB5 CRT port, but this has not been fully tested. • The Panel’s port must be enabled and set to 80 Columns Not Supervised. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-2269 Toll Fre
Resumo do conteúdo contido na página número 6
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 6 of 22 4 CONFIGURING THE FIELDSERVER AS A NOTIFIER NCA2/NFS2-3030 CLIENT For a detailed discussion on FieldServer configuration, please refer to the FieldServer Configuration Manual. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer (See “.csv” sample files provided with the FieldServer). This section documents and describes the parameters nece
Resumo do conteúdo contido na página número 7
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 7 of 22 Parameter Addresses For each SLC loop per Node Memory Type : Detector ; Module Fire Alarm 1 – 159 Security Life 160 – 318 Life Critical 319 – 477 Medical Emergency 478 – 636 Security Alarm 637 – 795 Critical Process 796 – 954 Supervisory 955 - 1113 Disabled 1114 – 1272 Prealarm 1273 – 1431 Active 1432 – 1590 ON/OFF 1591 – 1749 Memory Type : Detector_Trouble; Module_Trouble Troubles/Faults
Resumo do conteúdo contido na página número 8
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 8 of 22 4.2 Data Arrays/Descriptors The configuration file tells the FieldServer about its interfaces, and the routing of data required. In order to enable the FieldServer for Notifier NCA2/NFS2-3030 communications, the driver independent FieldServer buffers need to be declared in the “Data Arrays” section, the destination device addresses need to be declared in the “Client Side Nodes” section, and the required data from Notifier Panels n
Resumo do conteúdo contido na página número 9
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 9 of 22 4.3 Client Side Connection Descriptions Section Title Connections Column Function Legal Values Title Specify which port the device is connected to the 2 Port P1-P8 FieldServer Protocol Specify protocol used nfs2-nca; nca2; nfs2-3030 CRT Port 4800; 9600; 19200; 38400; 57600; (Vendor Baud* Specify baud rate limitation) Printer Port 9600 (Vendor limitation) Parity* Specify parity None (Vendor limitation) Data_Bits* Speci
Resumo do conteúdo contido na página número 10
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 10 of 22 4.5 Client Side Map Descriptors 4.5.1 FieldServer Related Map Descriptor Parameters Column Title Function Legal Values Map_Descriptor_Name Name of this Map Descriptor Up to 32 alphanumeric characters Name of Data Array where data is to be One of the Data Array names from “Data Data_Array_Name stored in the FieldServer Array” section above Any integer value Data_Array_Offset Starting location in Data Array 0 - one less than Da
Resumo do conteúdo contido na página número 11
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 11 of 22 4.5.3 Map Descriptor Example: Standard example This shows the standard Map Descriptor setup for one Node with 1 loop and all 159 modules and 159 detectors installed. This Node also has all boards, panel and bell circuits // // Client Side Map Descriptor // Define Map Descriptors to capture just required data // // Node 2 // Map_Descriptors Map_Descriptor_Name ,Data
Resumo do conteúdo contido na página número 12
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 12 of 22 5 CONFIGURING THE FIELDSERVER AS A NOTIFIER NCA2/NFS2-3030 SERVER This driver cannot be configured as a Server. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-2269 Toll Free: (888) 509-1970 email: support@fieldserver.com
Resumo do conteúdo contido na página número 13
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 13 of 22 Appendix A. Advanced Topics Appendix A.1. Notifier NCA2/NFS2-3030 Message Types Recognized Event Keyword Clearing Event Notes CLEARED FIRE FIRE ALARM states: {1,0} ALARM SECURITY CLEARED SECURITY states: {1,0} ALARM (LIFE) ALARM (LIFE) LIFE CRITICAL CLEARED LIFE states: {1,0} ALARM CRITICAL ALARM MEDICAL CLEARED MEDICAL states: {1,0} EMERGENCY EMERGENCY SECURITY CLEARED SECURITY states: {1,0} ALARM ALARM CRITICAL states:
Resumo do conteúdo contido na página número 14
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 14 of 22 Appendix A.2. System Trouble Messages The following table lists the system troubles theoretically recognized by this driver – only a selection have been tested. System Trouble Address System Trouble Address GROUND FAULT LOOP 1 1 STYLE 4 SHORT A L6 255 GROUND FAULT LOOP 2 2 STYLE 4 SHORT B L6 256 GROUND FAULT LOOP 3
Resumo do conteúdo contido na página número 15
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 15 of 22 System Trouble Address System Trouble Address ANNUN 6 TROUBLE 54 UNPROGRAMMED DEVICE ON LOOP 3 308 ANNUN 7 TROUBLE 55 UNPROGRAMMED DEVICE ON LOOP 4 309 ANNUN 8 TROUBLE 56 UNPROGRAMMED DEVICE ON LOOP 5 310 ANNUN 9 TROUBLE 57 UNPROGRAMMED DEVICE ON LOOP 6
Resumo do conteúdo contido na página número 16
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 16 of 22 System Trouble Address System Trouble Address ANALOG OUTPUT 1 TROUBLE 113 LIB #2 SCB RECEIVE ERROR 367 ANALOG OUTPUT 2 TROUBLE 114 LIB #3 SCB RECEIVE ERROR 368 ANALOG OUTPUT 3 TROUBLE 115 LIB #4 SCB RECEIVE ERROR 369 ANALOG OUTPUT 4 TROUBLE 116 LIB #5 SCB RECEIVE ERROR
Resumo do conteúdo contido na página número 17
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 17 of 22 System Trouble Address System Trouble Address REMOTE DISPLAY 8 NO ANSWER 172 TERM SUPERVISORY 426 REMOTE DISPLAY 9 NO ANSWER 173 CRT SUPERVISORY 427 REMOTE DISPLAY 10 NO ANSWER 174 TERMINAL SUPERVISORY PATH IS INTERRUPTE 428 REMOTE DISPLAY 11 NO ANSWER 175 NVRAM BATTERY TROUBLE
Resumo do conteúdo contido na página número 18
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 18 of 22 System Trouble Address System Trouble Address LOOP CONTINUITY TEST FAIL LOOP 3 231 WALK TEST - FIRE PROTECTION IS LIMITED 485 LOOP CONTINUITY TEST FAIL LOOP 4 232 REMOTE PROG MODE ACCESSED 486 LOOP CONTINUITY TEST FAIL LOOP 5 233 DIA PROG. CHANGE DET. SERVICE REQUIRED 487 LOOP CONTINUITY TEST FAIL LOOP 6 234 ISIB DATA MESSAGE RECEIVED ERROR
Resumo do conteúdo contido na página número 19
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 19 of 22 Appendix A.5. Driver Limitations and Exclusions • Zone information will not be recorded. • To synchronize the FieldServer with the panel, connect the running FieldServer and press the “System Reset” button on the panel. All current events will be re-sent to the FieldServer. • The port must be enabled on the unit and set to 80 columns with NO supervision • All data related to non-event driven reports will not be recorded by the Fi
Resumo do conteúdo contido na página número 20
FS-8700-130 Notifier NCA2/NFS-3030 Manual Page 20 of 22 Appendix B. Troubleshooting tips Appendix B.1. Connection Tips & Hints • Communication errors will be experienced if the port is disabled at the panel. Please check the Notifier Manuals on how to enable the panel port connected to the FieldServer and ensure that it is set to 80 columns NO supervision. • If connecting the Panel to one of the FieldServer RS-232 ports causes the FieldServer to reboot, then an Optical Isolator is re