Resumo do conteúdo contido na página número 1
RACADM Command Line
Reference Guide for
iDRAC6 1.95, iDRAC6 3.5, and
CMC 3.2
Resumo do conteúdo contido na página número 2
Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. _____________________ Information in this publication is subject to change without notice. © 2013 Dell Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in th
Resumo do conteúdo contido na página número 3
Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . 23 Supported RACADM Interfaces . . . . . . . . . . . . . 23 RACADM Syntax Usage . . . . . . . . . . . . . . . . . 24 Local RACADM . . . . . . . . . . . . . . . . . . . 24 SSH/Telnet RACADM . . . . . . . . . . . . . . . . 24 Remote RACADM. . . . . . . . . . . . . . . . . . 24 RACADM Command Options . . . . . . . . . . . . 25 Supported RACADM Subcommands. . . . . . . . . . . 26 Other Documents You May Need . . . . . . . .
Resumo do conteúdo contido na página número 4
clrsel . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 cmcchangeover . . . . . . . . . . . . . . . . . . . . . 42 config. . . . . . . . . . . . . . . . . . . . . . . . . . . 42 connect. . . . . . . . . . . . . . . . . . . . . . . . . . 45 coredump. . . . . . . . . . . . . . . . . . . . . . . . . 46 coredumpdelete . . . . . . . . . . . . . . . . . . . . . 47 deploy . . . . . . . . . . . . . . . . . . . . . . . . . . 47 feature . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Resumo do conteúdo contido na página número 5
getniccfg . . . . . . . . . . . . . . . . . . . . . . . . . 81 getpbinfo . . . . . . . . . . . . . . . . . . . . . . . . . 83 getpminfo . . . . . . . . . . . . . . . . . . . . . . . . 85 getraclog. . . . . . . . . . . . . . . . . . . . . . . . . 86 getractime . . . . . . . . . . . . . . . . . . . . . . . . 87 getredundancymode. . . . . . . . . . . . . . . . . . . 88 getsel. . . . . . . . . . . . . . . . . . . . . . . . . . . 89 getsensorinfo . . . . . . . . . . . . . . . . . . . . . . 90
Resumo do conteúdo contido na página número 6
ping6 . . . . . . . . . . . . . . . . . . . . . . . . . . 108 racdump . . . . . . . . . . . . . . . . . . . . . . . . 109 racreset. . . . . . . . . . . . . . . . . . . . . . . . . 112 racresetcfg . . . . . . . . . . . . . . . . . . . . . . . 113 remoteimage . . . . . . . . . . . . . . . . . . . . . . 114 serveraction . . . . . . . . . . . . . . . . . . . . . . 114 setassettag . . . . . . . . . . . . . . . . . . . . . . . 115 setchassisname . . . . . . . . . . . . . . . . . . . . 116 setf
Resumo do conteúdo contido na página número 7
testemail . . . . . . . . . . . . . . . . . . . . . . . . . 135 testfeature . . . . . . . . . . . . . . . . . . . . . . . . 136 testtrap . . . . . . . . . . . . . . . . . . . . . . . . . . 139 traceroute . . . . . . . . . . . . . . . . . . . . . . . . 140 traceroute6. . . . . . . . . . . . . . . . . . . . . . . . 141 usercertupload. . . . . . . . . . . . . . . . . . . . . . 141 usercertview. . . . . . . . . . . . . . . . . . . . . . . 143 version . . . . . . . . . . . . . . . . . . . . . . . . .
Resumo do conteúdo contido na página número 8
cfgNicIPv4Enable (Read/Write). . . . . . . . . . 156 cfgNicSelection (Read/Write) . . . . . . . . . . 157 cfgNicVLanEnable (Read/Write) . . . . . . . . . 158 cfgNicVLanId (Read/Write) . . . . . . . . . . . . 159 cfgNicVLanPriority (Read/Write) . . . . . . . . . 159 cfgDNSDomainNameFromDHCP (Read/Write). . 159 cfgDNSDomainName (Read/Write). . . . . . . . 160 cfgDNSRacName (Read/Write). . . . . . . . . . 160 cfgDNSRegisterRac (Read/Write) . . . . . . . . 161 cfgDNSServersFromDHCP (Read/Wr
Resumo do conteúdo contido na página número 9
cfgRhostsSyslogPowerLoggingEnabled . . . . . . 170 cfgRhostsSyslogPowerLoggingInterval . . . . . . 170 cfgUserAdmin . . . . . . . . . . . . . . . . . . . . . . 171 cfgUserAdminIndex (Read Only) . . . . . . . . . . 171 cfgUserAdminIpmiLanPrivilege (Read/Write) . . . 172 cfgUserAdminPrivilege (Read/Write) . . . . . . . 172 cfgUserAdminUserName (Read/Write) . . . . . . 174 cfgUserAdminPassword (Write Only) . . . . . . . 175 cfgUserAdminEnable (Read/Write). . . . . . . . . 175 cfgUserAdminSolEnable
Resumo do conteúdo contido na página número 10
cfgSerialHistorySize (Read/Write) . . . . . . . . 185 cfgSerialCom2RedirEnable (Read/Write). . . . . 185 cfgSerialSshEnable (Read/Write). . . . . . . . . 185 cfgSerialTelnetEnable (Read/Write) . . . . . . . 186 cfgOobSnmp . . . . . . . . . . . . . . . . . . . . . . 186 cfgOobSnmpAgentCommunity (Read/Write) . . . 187 cfgOobSnmpAgentEnable (Read/Write) . . . . . 187 cfgTraps . . . . . . . . . . . . . . . . . . . . . . . . 187 cfgTrapsIndex (Read Only) . . . . . . . . . . . . 188 cfgTrapsE
Resumo do conteúdo contido na página número 11
cfgRacTuneTimezoneOffset (Read Only) . . . . . . 195 cfgRacTuneLocalServerVideo (Read/Write) . . . . 196 cfgRacTuneLocalConfigDisable (Read/Write) . . . 196 cfgRacTuneWebserverEnable (Read/Write) . . . . 196 cfgRacTuneVirtualConsoleAuthorizeMultipleSessions (Read/Write) . . . . . . . . . . . . . . . . . . . . 197 cfgRacTunePluginType (Read/Write). . . . . . . . 197 ifcRacManagedNodeOs . . . . . . . . . . . . . . . . . 198 ifcRacMnOsHostname (Read Only) . . . . . . . . 198 ifcRacMnOsOsName (Read
Resumo do conteúdo contido na página número 12
cfgServerPowerBudgetAllocation (Read only). . 206 cfgServerDNSRegisterIMC (Read/Write). . . . . 206 cfgServerDNSIMCName (Read/Write) . . . . . . 206 cfgServerRootPassword (Write only) . . . . . . 206 cfgServerFirstBootDevice (Read/Write) . . . . . 207 cfgServerBootOnce (Read/Write) . . . . . . . . 207 cfgServerPowerConsumption (Read only) . . . . 208 cfgActiveDirectory. . . . . . . . . . . . . . . . . . . 209 cfgADRacDomain (Read/Write). . . . . . . . . . 210 cfgADRacName (Read/Write) .
Resumo do conteúdo contido na página número 13
cfgLdapEnable (Read/Write) . . . . . . . . . . . . 217 cfgLdapServer (Read/Write) . . . . . . . . . . . . 217 cfgLdapPort (Read/Write) . . . . . . . . . . . . . 217 cfgLdapBasedn (Read/Write) . . . . . . . . . . . 218 cfgLdapUserAttribute (Read/Write) . . . . . . . . 218 cfgLdapGroupAttribute (Read/Write). . . . . . . . 218 cfgLdapGroupAttributeIsDN (Read/Write) . . . . . 219 cfgLdapBinddn (Read/Write) . . . . . . . . . . . . 219 cfgLdapBindpassword (Write only) . . . . . . . . 219 cfgLdapSearch
Resumo do conteúdo contido na página número 14
cfgChassisPowerStatus (Read Only) . . . . . . . 226 cfgChassisRedundantState (Read Only) . . . . . 226 cfgChassisPowerCap (Read/Write). . . . . . . . 226 cfgChassisPowerCapF (Read/Write) . . . . . . . 227 cfgChassisPowerCapBTU (Read/Write) . . . . . 227 cfgChassisPowerCapFBTU (Read/Write). . . . . 227 cfgChassisPowerCapPercent (Read/Write) . . . 228 cfgChassisPowerCapFPercent (Read/Write). . . 228 cfgChassisRedundancyPolicy (Read/Write) . . . 228 cfgChassisDynamicPSUEngagementEnable (R
Resumo do conteúdo contido na página número 15
cfgIpmiLan . . . . . . . . . . . . . . . . . . . . . . . . 233 cfgIpmiLanEnable (Read/Write) . . . . . . . . . . 233 cfgIpmiLanPrivLimit (Read/Write) . . . . . . . . . 234 cfgIpmiLanAlertEnable (Read/Write). . . . . . . . 234 cfgIpmiEncryptionKey (Read/Write) . . . . . . . . 234 cfgIpmiPetCommunityName (Read/Write) . . . . . 234 cfgIpmiPetIpv6 . . . . . . . . . . . . . . . . . . . . . . 235 cfgIpmiPetIPv6Index (Read Only) . . . . . . . . . 235 cfgIpmiPetIPv6AlertDestIpAddr . . . . . . . . . . 23
Resumo do conteúdo contido na página número 16
cfgServerPeakPowerConsumptionTimestamp (Read Only) . . . . . . . . . . . . . . . . . . . . 240 cfgServerPowerConsumptionClear (Write Only). 241 cfgServerPowerCapWatts (Read/Write) . . . . . 241 cfgServerPowerCapBtuhr (Read/Write) . . . . . 241 cfgServerPowerCapPercent (Read/Write) . . . . 241 cfgServerPowerLastMinAvg (Read Only) . . . . 242 cfgServerPowerLastHourAvg (Read Only) . . . . 242 cfgServerPowerLastDayAvg (Read Only) . . . . 242 cfgServerPowerLastWeekAvg (Read Only) . . . 242
Resumo do conteúdo contido na página número 17
cfgServerCumulativePowerConsumptionTimeStamp (Read Only) . . . . . . . . . . . . . . . . . . . . . 251 cfgServerCumulativePowerClear (Write Only). . . 251 cfgServerPeakPowerClear (Write Only) . . . . . . 251 cfgServerPowerPCIeAllocation (Read/Write) . . . 252 cfgKVMInfo. . . . . . . . . . . . . . . . . . . . . . . . 252 cfgKVMAccessToCMCEnable . . . . . . . . . . . 252 cfgKVMFrontPanelEnable . . . . . . . . . . . . . 253 cfgAlerting . . . . . . . . . . . . . . . . . . . . . . . . 253 cfgAlerting
Resumo do conteúdo contido na página número 18
cfgIPv6Address3 (Read Only). . . . . . . . . . . 259 cfgIPv6Address4 (Read Only). . . . . . . . . . . 259 cfgIPv6Address5 (Read Only). . . . . . . . . . . 259 cfgIPv6Address6 (Read Only). . . . . . . . . . . 259 cfgIPv6Address7 (Read Only). . . . . . . . . . . 260 cfgIPv6Address8 (Read Only). . . . . . . . . . . 260 cfgIPv6Address9 (Read Only). . . . . . . . . . . 260 cfgIPv6Address10 (Read Only) . . . . . . . . . . 260 cfgIPv6Address11 (Read Only) . . . . . . . . . . 261 cfgIPv6Address
Resumo do conteúdo contido na página número 19
cfgCurrentIPv6DNSServer1 . . . . . . . . . . . . 266 cfgCurrentIPv6DNSServer2 . . . . . . . . . . . . 266 cfgIPv6URL. . . . . . . . . . . . . . . . . . . . . . . . 267 cfgIPv6URLstring (Read Only) . . . . . . . . . . . 267 cfgIpmiSerial. . . . . . . . . . . . . . . . . . . . . . . 267 cfgIpmiSerialBaudRate (Read/Write) . . . . . . . 267 cfgIpmiSerialConnectionMode (Read/Write) . . . 268 cfgIpmiSerialChanPrivLimit (Read/Write) . . . . . 268 cfgIpmiSerialFlowControl (Read/Write) . . . . . . 268 cf
Resumo do conteúdo contido na página número 20
cfgVFlashSD . . . . . . . . . . . . . . . . . . . . . . 275 cfgVFlashSDEnable (Read/Write). . . . . . . . . 275 cfgVFlashSDSize (Read Only). . . . . . . . . . . 275 cfgVFlashSDLicensed (Read Only) . . . . . . . . 276 cfgVFlashSDAvailableSize (Read Only). . . . . . 276 cfgVFlashSDHealth (Read Only) . . . . . . . . . 276 cfgVFlashSDWriteProtect (Read Only) . . . . . . 277 cfgVFlashPartition . . . . . . . . . . . . . . . . . . . 277 cfgVFlashPartitionIndex (ReadOnly) . . . . . . . 277 cfgV