3 Disclaimer and Warranty Disclaimer ADAPTEC reserves the right to make changes to this manual and the equipment described herein without notice. ADAPTEC has made all reasonable effort to insure that the information in this manual is accurate and complete. However, ADAPTEC shall not be liable for any technical or editorial errors or omissions made herein or for incidental, special, or consequential damage of whatsoever nature resulting from the furnishing of this manual, or operation and perform
Resumo do conteúdo contido na página número 4
4 ADAPTEC, freight prepaid. ADAPTEC, upon verifi- cation of warranty, will repair or replace at its option the 2Gb SANbloc component in question, and will then return the product to the Purchaser, freight prepaid. Cable Warranty - All ADAPTEC provided cables are warranted for ninety (90) days from the time of shipment. Questionable cables should be returned to ADAPTEC, freight prepaid where they will be repaired or replaced by ADAPTEC at its option and returned to the Purchaser, freight pre
Resumo do conteúdo contido na página número 5
5 Returned Material - Warranty claims must be received by ADAPTEC within the applicable warranty period. A replaced product, or part thereof, shall become the property of EUROLOGIC and shall be returned to ADAPTEC at Purchaser’s expense. All returned material must be accom- panied by a Return Materials Authorization (RMA) number assigned by ADAPTEC. For RMA numbers contact ADAPTEC Customer Support Monday-Friday 3am-5pm PST at: Telephone: 321-207-2000 (RAID, FC, External Storage) 408-934-7274 (H
Resumo do conteúdo contido na página número 6
6 THE EXPRESSED WARRANTIES SET FORTH IN THIS AGREEMENT ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND ALL SUCH OTHER WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED BY EUROLOGIC. THESE STANDARD EXPRESS WARRANTIES ARE IN LIEU OF ALL OBLIGATIONS OR LIABILITIES ON THE PART OF EUROLOGIC FOR DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES ARISING OUT OF O
Resumo do conteúdo contido na página número 7
7 Table of Contents Preface .................................................................................13 Audience .................................................................................................. 13 Conventions Used In This User Guide .................................................... 13 Getting Support........................................................................................ 14 FCC Statement.................................................................
Resumo do conteúdo contido na página número 8
8 Mechanical Loading ........................................................................ 31 Electrical Considerations ......................................................................... 32 Circuit Overloading ......................................................................... 32 Setting Fibre Channel Loop Speed (2Gb or 1Gb) ................................... 32 2Gb Operation ................................................................................. 32 1Gb Operation .....
Resumo do conteúdo contido na página número 9
9 Controller Circuit Board.................................................................. 49 I/O Circuit Board............................................................................. 50 Ethernet Circuit Board..................................................................... 50 RAID Controller Location............................................................... 51 RAID Controller Status LEDs......................................................... 52 RAID Controller Configurations .
Resumo do conteúdo contido na página número 10
10 Removing a Disk Drive Carrier....................................................... 77 Installing and Removing an LS Module .................................................. 79 Installing an LS Module .................................................................. 79 Removing an LS Module................................................................. 79 Installing and Removing a Power Supply................................................ 81 Installing a Power Supply...................
Resumo do conteúdo contido na página número 11
11 AC Power Supply Input................................................................... 97 Temperature ............................................................................................. 97 Humidity .................................................................................................. 97 Altitude .................................................................................................... 98 Operational Shock.......................................................
Resumo do conteúdo contido na página número 12
12
Resumo do conteúdo contido na página número 13
13 Preface This Installation Guide describes the installation and operation of the 2Gb SANbloc Series. The following products are covered: FC2101CDT2-AC, FC2101CDR2-AC, FC2101ODT2-AC, FC2101ODR2-AC, FC2101MDT2-AC, FC2101MDR2-AC. Audience This Installation Guide is intended for use by the person installing and operating the 2Gb SANbloc Series. This Installation Guide describes the operation of the 2Gb SANbloc Series only. For details relating to the host system, refer to the documentation
Resumo do conteúdo contido na página número 14
14 Getting Support If you are having difficulties installing or operating your 2Gb SANbloc Series you can contact our World Wide Support Centre for assistance Monday-Friday 3am to 5pm Pacific: Telephone: 321-207-2000 (RAID, FC, External Storage) 408-934-7274 (Hardware) email: ask.adaptec.com WWW http://www.adaptec.com/support FCC Statement WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate t
Resumo do conteúdo contido na página número 15
15 VCCI English Translation: This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment. If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. European Community Statement This equipment complies with the following European direc- tives: EMC Directive 89/336/EEC and amending Directives 92/31/ EEC and 93/68/EEC L
Resumo do conteúdo contido na página número 16
16 Safety Statements The following safety statements must be read before installation. For language translations of these statements refer to Appendix B. CAUTION: This equipment is intended only for installation in a restricted access location. CAUTION: Allow disk drives and power supplies to reach room ambient temperature before powering on the system. CAUTION: It is recommended that if interconnecting equipment resides within more than one equipment rack cabinet, these cabi- nets should b
Resumo do conteúdo contido na página número 17
17 CAUTION: The tower skin set is not a field replaceable unit and therefore must not be removed from the Storage Array. CAUTION: After removing the LS Module the resulting hole must be blocked, by installing a blanking plate or by installing a replacement LS Module. Failure to do so can disrupt air flow and seriously reduce cooling. WARNING: A possible shock hazard may exist in the area of the fan connection. WARNING: Disconnect the power cord before removing the power supply from the sto
Resumo do conteúdo contido na página número 18
18 Safety Statements
Resumo do conteúdo contido na página número 19
19 Chapter 1: Introduction This Chapter introduces the 2Gb SANbloc Series. The main features of the Series are described along with a list of the models that are available. Introduction The 2Gb SANbloc Series provides a highly flexible, high performance storage solution that evolves to meet your changing needs. Based on a modular, “building block” enclosure design, the 2Gb SANbloc Series offers exceptional scalability. Each enclosure supports up to 14 disk drives, or 1TB of capacity in a
Resumo do conteúdo contido na página número 20
20 • Downward compatible to 1GB. • Dense enclosure with 14 drives in a 3U form factor. • Scalable to 8.2TB (112 drives), support for 15K rpm drives. • Enhanced enclosure services (SES) monitoring and reporting. • No single point of failure, with redundant, hot-swappable components. • Intuitive, comprehensive management with Spheras Storage Manager. • User installable, configurable and on-line maintainable. • Industry-standard 19-inch rackmount or deskside configuration. • Dual AC power supplie