Resumo do conteúdo contido na página número 1
4-663-202-81(1)
AIT Library
Operating Instructions
Before operating the unit, please read this manual
thoroughly and retain it for future reference.
LIB-81
© 2002 Sony Corporation
Resumo do conteúdo contido na página número 2
INFORMATION You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment. WARNING To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only. Caution The mains plug on this equipment must be used to disconnect mains power. Please ensure that the socket outlet is installed near the equ
Resumo do conteúdo contido na página número 3
ATTENTION According to the EU Directives related to product safety, EMC and R&TTE the manufacturer of this product is Sony Corporation, 1-7-1 Konan Minato-ku Tokyo, 108-0075 Japan. The Authorised Representative is Sony Deutschland GmbH, Hedelfinger Strasse 61,70327 Stuttgart, Germany. For any service or guarantee matters please refer to the addresses given in separate service or guarantee documents. AUFMERKSAMKEIT Im Sinne der EU Richtlinien bezüglich Produktsicherheit, EMV und R&TTE ist Sony
Resumo do conteúdo contido na página número 4
Table of Contents Chapter 1 Introduction Overview.......................................................................7 Product Features and Functions ...............................8 Front................................................................................ 8 Rear ................................................................................. 9 Bottom........................................................................... 10 System Structure..................................
Resumo do conteúdo contido na página número 5
Basic Settings............................................................43 Disabling the Life Warning Display ............................. 43 Setting the Bar Code ..................................................... 44 Setting the R-MIC Function.......................................... 44 Adjusting the Brightness of the LCD Panel.................. 45 Using the Sequential Mode........................................... 46 Disabling the Buttons on the Front Panel...............47 Assigned Ele
Resumo do conteúdo contido na página número 6
Information Menu ......................................................86 Information.................................................................... 86 Inventory ....................................................................... 87 Appendix If You Forget the Password ......................................89 Changing the Air Filter 1...........................................89 Changing the Air Filter 2...........................................91 Troubleshooting .......................
Resumo do conteúdo contido na página número 7
Introduction Chapter Overview The LIB-81 is an AIT (Advanced Intelligent Tape) library with a built-in AIT drive. Up to 8 cartridges can be set and used. The unit can also be connected to, and used with, a workstation or server. Up to 8 cartridges can be set Up to 8 AIT cartridges can be set. Cartridges can be replaced from the front panel. When the AIT library is equipped with a bar code reader, bar code labels can be used to manage cartridges. The following types of cartridges can be used
Resumo do conteúdo contido na página número 8
Notes � Cartridges that can be used vary according to the type of built-in drive. � The memory capacity mentioned above assumes the use of all 8 AIT cartridges, no compression. � For combinations other than those mentioned above, refer to the attached sheet. The AIT library can be remotely controlled A browser can be used to configure individual settings. It can also be used to view library and maintenance information. LVD SCSI compliant The LIB-81/A5, LIB-81/A4, LIB-81/A3X, and LIB-81/A3 mod
Resumo do conteúdo contido na página número 9
A Front Panel There are two shapes for the front panel. B Power Indicator LED This LED light is on when the power is turned on. C Cartridge Dock Load and exchange cartridges in the cartridge dock. When the cartridge dock is specified using the control buttons, its shutter opens automatically. The library does not operate while the cartridge dock shutter is open, so close the shutter using the control buttons after loading or exchanging cartridges. D Liquid Crystal Display The LCD panel displa
Resumo do conteúdo contido na página número 10
E SCSI connector 1 6 SCSI connector 2 For information about connecting the SCSI connectors, refer to “Connecting to the Host Computer” (page 17) and “Connecting SCSI Peripheral Devices” (page 19) in Chapter 2, “Installation”. G LAN Connector Connect a 10Base-T/100Base-TX network cable here. Bottom DIP Switches for Setup The default setting of the DIP switches is as follows. Use the DIP switches as is. For details, refer to “Setting the DIP Switches” (page 18) in Chapter 2, “Installation”. Sys
Resumo do conteúdo contido na página número 11
Operating systems: - Microsoft Windows 95, Microsoft Windows 98, Microsoft Windows Me, and Microsoft Windows 2000 Browsers: - Microsoft Internet Explorer 5.01 or later - Netscape Communicator 4.7 or later Compatible Data Cartridges This section describes data cartridges used in the AIT library. AIT Cartridges AIT cartridges for use with your built-in AIT drive can be used in the AIT library. To achieve the maximum transfer rate and recording capacity, use the optimum cartridges for your type
Resumo do conteúdo contido na página número 12
Built-in AIT-1 drive (LIB-81/A1 models) AIT-1 mark Caution � Do not use 8 mm video tapes sold at stores. An 8 mm video tape looks a lot like an AIT cartridge, but has different specifications. Do not use any cartridge other than those listed above. Use only designated AIT data cartridges. � For combinations other than those mentioned above, refer to the attached sheet. Cleaning Cartridges To clean the AIT drive, use an AIT Cleaning cartridge. There are four types of cleaning cartridges: the
Resumo do conteúdo contido na página número 13
Installation Chapter Overview This chapter explains general procedures for positioning the AIT library, connecting it to the host computer and turning on the library power. This chapter also explains initial setup. Installation and setup steps may vary depending on your system. After turning on the power, make settings required to use the unit as explained in “Initial Setup” (page 22). Unpacking Note You will need the box, packing materials and transport screw if you wish to move or transpo
Resumo do conteúdo contido na página número 14
2 Remove the transport screw (turn counterclockwise) from the Shipping position (upper hole) at the rear of the library, and then set it in the Operation position (lower hole) with a screw driver or coin. Transport screw Operation position Checking the Package Contents After opening the package, make sure all of the following items are present. Contact your dealer if anything is missing. � LIB-81 AIT Library (1) � Power cable (1) � SCSI terminator (1) � Quick Start Guide (1) � Air Filter (ACY
Resumo do conteúdo contido na página número 15
430 mm (16.9 in.) 1˚ 1˚ Installing the AIT Library The library weighs about 13.5 kg (29.8 lb.) and has the following dimensions. Before installing the library, make sure that the surface on which you are placing it is large and strong enough. Also, set the library horizontally so that its front and sides are inclined by no more than ±1 degree in any direction. Front Side 15 Chapter 2 Installation 43 mm (1.75 in.) (1U) 1˚ 1˚ 660 mm (26.0 in.)
Resumo do conteúdo contido na página número 16
With the ACY-RK81 rack mounting kit (sold separately), the AIT library can be installed on an EIA-standard, universal pitch 19-inch rack. Contact your dealer for information about the rack mounting kit. Note Install the AIT library on a horizontal surface near an AC power outlet. Also, leave a gap of about 150 mm (5.9 in.) behind the rear of the unit to allow air to circulate. Rear 150 mm (5.9 in.) Front 430 mm (16.9 in.) 660 mm (26.0 in.) Connecting the Power Cable 1 Confirm that the power
Resumo do conteúdo contido na página número 17
Connecting to the Host Computer Connect the AIT library and the host computer with a SCSI cable. This section explains general connecting steps. Connect the library with the appropriate SCSI cable, depending on the AIT drive. � When the library is equipped with the AIT-5, AIT-4, AIT-3 Ex, or AIT-3 drive, use a generic Ultra 160 cable. � When the library is equipped with the AIT-2 or AIT-1 drive, use a generic Wide Ultra LVD SCSI cable that conforms to SCSI-3. The library side uses the 68-pin
Resumo do conteúdo contido na página número 18
2 Attach the provided terminator to the other connector. Host computer 1 2 Terminator Setting the DIP Switches DIP switch settings determine whether electric power is supplied to the SCSI terminator (when multiple SCSI devices are connected). DIP Switches for Setup Bottom The default factory setting of the DIP switches is as follows. 1-7: On (Do not change this default setting.) Used for expansion purposes 8: On ON: SCSI TERM POWER ON OFF: SCSI TERM POWER OFF To set the DIP switches: 18 Chapter
Resumo do conteúdo contido na página número 19
1 Press the power switch to turn off the power. 2 Use a pointed object such as a machinist’s screwdriver to change the settings of the DIP switches. 3 Press the power switch to turn on the power. Connecting SCSI Peripheral Devices SCSI peripheral devices can be connected to the SCSI connectors of the AIT library. The SCSI configuration of the library is as shown below. Connect the devices according to the system environment. Library SCSI Connector 2 AIT Drive SCSI Connector 1 Library Control
Resumo do conteúdo contido na página número 20
1 Press the power switch on the rear of the library. The messages on the right appears and the startup process begins. LIB-81 (Startup takes several minutes.) Initializing When the startup process ends, the Jan/01/2001 12:00:00 library enters the time setting mode. [ENTER] to set the Date and Time [CANCEL] to exit Caution Models equipped with a bar code reader By default, the library is not set to read bar codes. If you modify this setting so that the library can read bar codes a