Resumo do conteúdo contido na página número 1
The.Danger.signal.indicates.an.immediately.hazardous.situation.which,.
if.not.avoided,.will result.in.death.or.serious.injury.
The.Warning.signal.alerts.you.to.potential.hazards.or.unsafe.practices.which,.
if.not.avoided,.could result.in.severe.personal.injury.or.death.
The.Caution.signal.alerts.you.to.hazards.of.unsafe.practices.which,.if.not.avoided,.
may.result.in.minor.personal.injury.or.property.damage.
Please.be.certain.that.the.person.who.installs.or.uses.this.appliance.carefully.
reads.a
Resumo do conteúdo contido na página número 2
Table of Contents Warranty...........................................................................................................4 Introduction/Typical Installation . Introduction.......................................................................................4 . Typical.Installation.............................................................................4 Waste Xpress Features...................................................................................5 WX-101A Control Featu
Resumo do conteúdo contido na página número 3
Warranty WASTE XPRESS SYSTEM LIMITED WARRANTY ® ® The.InSinkErator .Waste.Xpress,.disposer.and.control.centers.are.warranted.against.defects.in.material.and. workmanship.for.one.year.from.the.date.of.installation..The.warranty.includes.parts.and.labor,.provided.an.. InSinkErator.Factory.Authorized.Service.Center.performs.the.service..This.warranty.does.not.apply.if.the.failure.. is.due.to:.faulty.or.improper.electrical.installation,.faulty.or.improper.plumbing.installation,.product.abuse.or.. mi
Resumo do conteúdo contido na página número 4
Waste Xpress Features CONSTRUCTION FEATURES Stainless.steel.construction.(for.physical.size.see.. COMPACT.SIZE ® Figure.3). The.Waste.Xpress .is.designed.to.fit.under.a.34".high commercial.kitchen.table. WASTE.MIX The.Waste.Xpress.can.process.non-food.waste.such WASTE.REDUCTION as.paper,.light.and.rigid.plastic.or.food.wrappings.when Reduces.volume.by.85%. mixed.with.a.minimum.of.50%.food.waste. SAFETY.INTERLOCK The.Waste.Xpress.is.equipped.with.safety.interlock.. on.the.discharge.chute.(see.Fig
Resumo do conteúdo contido na página número 5
WX-101A Control Features/Mounting Control Center ® The.WX-101A.Control.Center.is.UL .approved.for.use. with.InSinkErator.Waste.Xpress.food.waste.reduction. systems..The.control.center.operates.the.disposer.and. ELECTRICAL SHOCK Waste.Xpress..Its.main.functions.are: .•.Ensure.that.Waste.Xpress.voltage.and.phase. match.that.of.the.electrical.supply,.control.center.. •.To.start.and.stop.the.disposer/Waste.Xpress.system. &.disposer..Check.nameplate.for.specification. •.To.reverse.the.direction.of.th
Resumo do conteúdo contido na página número 6
Installing Disposer CLEAN.THE.DRAIN.LINE With.a.drain.line.auger,.clear.away.all.hardened.waste material.in.the.horizontal.drainpipe.running.from.the PERSONAL INJURY drain.trap.to.the.main.waste.line. .•.For.safe.operation,.The.minimum.required.distance . from.the.table.top.or.trough.to.the.mounting.flange. is.6.inches.for.standard.body.disposers.. (as.specified.by.UL)..See.Figure.5. 6" min. (152.4 mm min.) .•.Moving.shredder.parts.may.cause.serious.injury.if. a.hopper.or.cone.is.not.properly.in
Resumo do conteúdo contido na página número 7
InSinkErator Mounting Assemblies 4..From.the.bottom,.insert.two.screws.through.opposite STANDARD MOUNTING ASSEMBLY . sides.of.the.flat.gasket.(3).and.mounting.flange,.into 1..Place.mounting.flange.(1).over.the.existing.collar . the.threaded.fasteners.in.the.existing.flange..The . adaptor.connection.lip.or.sink.bowl.flange.(this.may . flat.gasket.is.used.only.in.the.#6.mounting.assembly. . require.some.force). . The.screws.should.protrude.about.1/4".below.the 2..Push.the.mounting.flange.up.out.of
Resumo do conteúdo contido na página número 8
Installing the Waste Xpress 45˚ bend shown (max of 4 can be used) 1-1/2" 3" (38.1 mm) (76.2 mm) Figure 11. Top View Syphon Breaker Sink Bowl Cold Water Solenoid Hot Water Solenoid Waste Xpress 1-1/2" min 1" min (38.1 mm (25.4 mm min) min) Disposer Flow Control Valve Shut Off Valve (supplied by others) WX-101A Controller 10 max (3.1 m max) Figure 12. Typical Installation Diagram 9
Resumo do conteúdo contido na página número 9
Installing the Waste Xpress 7....Connect.wire.bundle.between.WX-101A.and.. WASTE XPRESS LOCATION Waste.Xpress.unit.as.detailed.in.wiring.diagram.. NOTE: Prior to installing the Waste Xpress the Door.interlock.connections.are.#3.and.#95..Replace. disposer and control center should be installed as terminal.cover. specified within this manual. 8....Wire.per.local.electrical.codes.and.install.. •.Position.Waste.Xpress.within.10.feet.of.the.disposer using.NEMA.4.watertight.electrical.connectors.. out
Resumo do conteúdo contido na página número 10
Plumbing Connections PROPERTY DAMAGE Water.connections.must.comply.with.all.local. plumbing.codes. WASTE INLET LINE Connect.the.disposer.outlet.flange.as.close.as.. possible.and.with.as.few.as.possible.90°.elbows.to.. the.Waste.Xpress.inlet. NOTE: The maximum allowable distance between the Figure 15. disposer outlet flange and the Waste Xpress inlet is 10 feet with a maximum of four (4) 90° elbows. 1..Connect.the.disposer.outlet.to.the.Waste.Xpress.. . inlet.using.2".NPT.plumbing..3.HP.will.re
Resumo do conteúdo contido na página número 11
Plumbing Connections WASTE OUTLET LINE WATER SUPPLY CONNECTIONS Connect.a.2".drain.line.to.the.Waste.Xpress.waste.. When.connecting.the.incoming.water.supply.to.the outlet.as.specified.per.local.codes.(see.Figure.18.. disposer,.sink.bowl.and.Waste.Xpress,.use.as.few for.water.outlet.location). elbows.and.tees.as.possible. InSinkErator.recommends.that.the.water.outlet.. All.cold.water.line.fittings.are.1/2".NPT.except.the empties.into.a.floor.drain. sink.bowl.nozzles.which.are.1/2".compression...
Resumo do conteúdo contido na página número 12
Electrical Connections ELECTRICAL SHOCK PROPERTY DAMAGE .•.Turn.off.all.electrical.supply.to.the.disposer.before. .•.Ensure.that.control.center.voltage.and.phase attempting.any.work.on.it..Use.a.voltmeter.or.. . match.the.disposer.motor.and.electrical.supply... circuit.tester.to.ensure.that.power.is.off. . Check.nameplates.on.disposer.and.control.. . center.for.voltage.and.phase.specifications. .•.All.Installation.work.must.conform.to.local.. plumbing.and.electrical.codes. .•.Refer.to.the.contro
Resumo do conteúdo contido na página número 13
Operating Instructions PRE-OPERATION TEST Before.operating.the.Waste.Xpress.complete.. the.following.steps.to.ensure.the.unit.has.been.. PERSONAL INJURY properly.installed. If.system.does.not.shut.down.when.front.. cover/discharge.chute.is.removed,.interlock.may. 1....Ensure.plumbing.and.electrical.connections.. not.be.wired.correctly..See.Troubleshooting.section. are.secure. for.corrective.action. 2....Turn.on.incoming.cold.water.supply.to.disposer.. and.hot.water.supply.to.the.Waste.Xpress. 3.
Resumo do conteúdo contido na página número 14
Operating Instructions TO.START 1..Check.to.ensure.disposer.is.free.of.foreign.objects. 2..Ensure.power.is.on. 3..Push.start.button..Disposer.and.Waste.Xpress.will. run.and.water.will.flow.into.disposer TO.STOP 1..Push.stop.button..System.will.stop. 2..Water.may.continue.to.flow.into.disposer.for.up.to.. 10.minutes,.per.the.time.set.on.the.water.shutoff. delay.timer..This.post-flush.clears.the.drain.lines.. of.food.waste. WATER.SHUTOFF.DELAY.ADJUSTMENT This.water.shutoff.delay.is.adjustable.from
Resumo do conteúdo contido na página número 15
Operating Instructions OPERATING WASTE XPRESS SYSTEM 1..Make.sure.there.are.no.foreign.objects.in.disposer. grind.chamber..Do.not.pre-load.disposer.with.food. waste.prior.to.starting. 2..Place.10.gallon.waste.bin.under.discharge.chute. 3..Push.start.button.on.control.center..Waste.Xpress. and.disposer.will.run.and.water.will.flow.into.disposer. 4..Feed.food.waste.into.disposer.in.a.steady,.. continuous.flow..Waste.will.exit.discharge.chute.. and.drop.into.waste.bin. NOTE: Once all waste has been
Resumo do conteúdo contido na página número 16
Cleaning Instructions PERSONAL INJURY Discharge Chute Wait.until.auger.paddles.stop.before.cleaning. Waste.Xpress. 1....Press.stop.button.on.control.center.to.stop.system. (disposer.&.Waste.Xpress). 2....Holding.both.handles.remove.discharge.chute.by.. tilting.it.upward.(see.Figure.25). 3....Remove.auger-bearing.bracket.by.sliding.the.two. captive.fasteners.inward.and.then.pull.bracket.. Figure 25. upward.(see.Figure.26.and.27). 4....Lift.auger.and.screen.up.and.then.out.. (see.Figure.26). 5....
Resumo do conteúdo contido na página número 17
Troubleshooting ELECTRICAL SHOCK PERSONAL INJURY •.Disconnect.power.before.servicing. Wait.until.auger.paddles.stop.before.servicing. Waste.Xpress. •.Do.not.bypass.interlock.switch. Troubleshooting.for.problems.other.than.what.is.listed.below.should.be.performed.by.a.qualified.service.person.. Troubleshooting.performed.by.untrained.personnel.could.result.in.electrical.shock.or.damage.to.the.Waste.Xpress,. disposer.and/or.Control.Center. SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION The.
Resumo do conteúdo contido na página número 18
Troubleshooting SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Water.backs.up.into.disposer.. •. The.auger.and.screen.plugged. •. Remove.plug. (does.not.drain). •. Auger.not.turning.. •. Ensure.that.auger.is.seated.properly.and.. . that.auger.belt.in.place..Check.motor. •. Plumbing.line.between.disposer.and.. •. Remove.clog. . Waste.Xpress.clogged. Waste.Xpress,.disposer.and.water. •. Insufficient.time.allowed.after.Line.. •. Allow.15-20.seconds.prior.to.attempting.. will.start.when."sta
Resumo do conteúdo contido na página número 19
Troubleshooting SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION No.water.spraying.onto.. •. Solenoid.valve.clogged. •. Remove.clog. auger.screen. •. Water.turned.off. •. Turn.on.water. •. Solenoid.valve.defective. •. Call.for.service. •. Spray.nozzles.clogged. •. Replace.nozzles. •. Timer.defective. •. Call.for.service. •. Timer.not.set.properly. •. Call.for.service. •. Solenoid.valve.installed.incorrectly. •. Reinstall.solenoid.valve.so.arrow.is.pointing. . in.correct.direction. Water.fl
Resumo do conteúdo contido na página número 20
Troubleshooting DISPOSER TROUBLESHOOTING PROBLEM CAUSE SOLUTION Disposer.motor.will.not.start.and. •. No.incoming.line.power. •. Turn.line.power.on. water.does.not.flow. •. Line.disconnect.switch.is.not.on.. •. Turn.line.disconnect.to."on".position..Wait.. . . 15-20.seconds.before.attempting.to.start.. . system.to.allow.control.to.perform."self.test." •. Line.disconnect.switch.has.been.. •. Wait.30.seconds.and.try.starting.again.. . reactivated.and.30-second.delay.. . . has.not.yet.expired. •. L