Resumo do conteúdo contido na página número 1
DO NOT
DISCARD
Owner’s Manual
Installation and Operation
TIARA PETITE B
DIRECT VENT ROOM HEATER
Model:
Tested and Portland
O-T O-T L
Oregon USA
Listed by
C US
TIARAP-BK
OMNI-Test Laboratories, Inc.
TIARAP-BR
TIARAP-CES
TIARAP-CTO
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and
• Important operating and • Leave this manual with
follow these instructions
maintenance instructions party responsible for use
included. for safe installation and
and operation.
operation.
WARNING
WA
Resumo do conteúdo contido na página número 2
Read this manual before installing or operating this appliance. Please retain this owner's manual for future reference. Congratulations Congratulations on selecting a Heat & Glo gas appliance - an This Owner's Manual should be retained for future reference. elegant and clean alternative to wood burning appliances. We suggest that you keep it with your other important The Heat & Glo gas appliance you have selected is designed documents and product manuals. to provide the utmost in safety, reli
Resumo do conteúdo contido na página número 3
- TABLE OF CONTENTS - Section 7: Electrical Information Section 1: Listing and Code Approvals A. Recommendation for Wire ..................29 A. Appliance Certifi cations ......................4 B. Connecting to the Appliance ...............29 B. Glass Specifi cations ............................4 C. Standing Pilot Ignition System C. Specifi cations ......................................4 Wiring ..................................................29 D. High Altitude Installations .........
Resumo do conteúdo contido na página número 4
Listing and Code Approvals 1 C. Specifi cations A. Appliance Certifi cation Maxi- Mini- Orifi ce *Steady **P.4 MODEL Tiara Petite B Model mum mum Size State % (US or Canada) Input Input (DMS) Effi ciency LABORATORY OMNI-Test Laboratories, Inc. BTU BTU % 061-S-47b-5 Tiara Petite B (NG) 17,000 12,000 49 73.93 57.30 TYPE Vented Gas Fireplace Heater Tiara Petite B (LP) 17,000 13,000 56 78.19 63.22 STANDARD ANSI Z21.88b-2003 ּ CSA 2.33b-2003 ּ *Maximum Vent Blower On UL307b ּ CAN/CBA 2.17-M91 **Ca
Resumo do conteúdo contido na página número 5
Inspection NOTE: The following requirements reference various The state or local gas inspector of the side wall horizontally Massachusetts and national codes not contained in this vented gas fueled equipment shall not approve the installa- document. tion unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with G. Requirements for the Commonwealth of the provisions of 248 CMR 5.08(2)(a) 1 through 4. Massachusetts Exemption
Resumo do conteúdo contido na página número 6
Getting Started 2 C. Inspect Appliance & Components A. Design & Installation Considerations Heat & Glo direct vent gas appliances are designed to oper- ate with all combustion air drawn from outside of the building WARNING and all exhaust gases expelled to the outside. No additional air source is required. Inspect appliance and components for damage. Damaged parts may impair safe operation. • Do NOT install damaged components. CAUTION • Do NOT install incomplete components. Check building c
Resumo do conteúdo contido na página número 7
Appliance Location and Clearances 3 NOTE: WARNING · Illustrations refl ect typical installations and are FOR Fire Risk DESIGN PURPOSES ONLY. Provide adequate clearance: · Illustrations/diagrams are not drawn to scale. • Around air openings • To combustibles · Actual installation may vary due to individual design • For service access preference. Locate appliance away from traffi c areas. A. Selecting Appliance Location WARNING When selecting a location for your appliance it is importan
Resumo do conteúdo contido na página número 8
Termination Locations 4 A. Vent Termination Minimum Clearances HORIZONTAL OVERHANG WARNING 2 FT. 20 INCHES MIN. VERTICAL Fire Risk. MIN. WALL Explosion Risk. LOWEST DISCHARGE Maintain vent clearance to combustibles OPENING as specifi ed. GAS DIRECT VENT TERMINATION CAP • Do not pack air space with insulation or other materials. X 12 Failure to keep insulation or other materials away from vent pipe may cause fi re. ROOF PITCH IS X/ 12 H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OP
Resumo do conteúdo contido na página número 9
M N P R G v A H D Q (See Note 2) E v V B L U.S. B T v (3 FT) v B B v S S Electrical V V Service F v v M I D* v X A J or K V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED V K = 3 ft. (U.S.A.) A = 12 inches ............. clearances above grade, veran- 6 ft. (Canada) ......... clearance to a mechanical (See Note 1) da, porch, deck or balcony (powered) air supply inlet B = 12 inches ............ clearances to window or door L** = 7 ft. ......................... clearanc
Resumo do conteúdo contido na página número 10
Vent Information 5 A. Venting Components B. Use of Elbows In order to comply with applicable codes and product warranties, use only following venting components: CAUTION • Hearth & Home Technologies (HHT) ALL vent confi guration specifi cations MUST be followed. • Simpson Dura-Vent • This product is tested and listed to these specifi cations. • Selkirk Direct-Temp • Appliance performance will suffer if specifi cations are • Amerivent Direct not followed. • Security Secure Vent Diagonal r
Resumo do conteúdo contido na página número 11
D. How to Use the Vent Graph E. Venting Guidelines 1. Measure the distance from the top of appliance to the Notes: center of the 90° elbow. On the graph below, draw a • The maximum horizontal vent run is 15 ft. (5m) when the horizontal line from that measurement on the vertical vertical vent rise is 10 ft. (3m). axis across until it intersects with the slanted line. • Horizontal sections require a 1/4 in. (6mm) rise for every 2. From the point of this intersection, draw a vertical line to
Resumo do conteúdo contido na página número 12
F. Horizontal Termination WARNING Fire Hazard. Type A - Up & Out Installation Exhaust Fume Risk. TERMINATION CAP Impaired Performance of Appliance. 90° ELBOW • Ensure vent components are locked together correctly. CENTER LINE • Pipe may separate if not properly joined. PIPE LENGTH WALL THIMBLE Step 2. WALL THIMBLE COVER Direct vent pipe is designed with a locking connection. To connect the venting system to the appliance flue outlet, a PIPE LENGTH twist-lock adapter is built into the appli
Resumo do conteúdo contido na página número 13
Step 3. Step 4. For installations using a round support box/wall thimble Position the horizontal termination cap in the center of the 10 (check pipe manufacturer's instructions), mark the wall for a in. x 10 in. (254mm x 254mm) square hole and run a bead 10 in. x 10 in. (254mm x 254mm) square hole. The center of non-hardening mastic around its outside edges, so as to of the square hole should line up with the center line of the make a seal between it and the wall, attach termination cap h
Resumo do conteúdo contido na página número 14
(NOTE: Some termination caps may cause the vent Note: The attachment from the vent pipe to the vent pipe to be off center on flashing). Ensure that proper termination cap must be sealed with silicone. Termination clearances to combustible materials are maintained. caps shall not be recessed into a wall or siding. If you are not using an approved termination cap with a built-in standoff on a building with vinyl siding, a vinyl siding standoff should be installed between the WARNING ter
Resumo do conteúdo contido na página número 15
G. Vertical Termination 1. Direct Vent Pipe VERTICAL TERMINATION CAP STORM COLLAR 25 ft. (8m) FLASHING MAXIMUM FIRESTOP SUPPORT BOX PIPE LENGTH Figure 5.11 Step 2. Set the gas appliance in its desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the
Resumo do conteúdo contido na página número 16
Step 3. To install the round support box/wall thimble cover in a flat CAP AND STORM ceiling, cut a 10 in. (254mm) square hole in the ceiling, Shingles overlap on COLLAR NOT SHOWN top edge of flashing FOR CLARITY centered on the hole drilled in Step 2. Frame the hole as shown in Figure 5.13. Ceiling Joists Framing Figure 5.14 Step 7. Continue to assemble pipe sections until the height of the 1 - 1/2 in. (38mm) Long vent (before adding the termination cap) meets the minimum Wood Screws
Resumo do conteúdo contido na página número 17
Step 9. Twist-lock the vent cap and seal. Note: For multi-story vertical installations, a ceiling firestop is required at the second floor, and any subsequent floors (Figure 5.16). The opening should be framed to 10 in. x 10 in. (254mm x 254mm) inside dimensions, in the same manner as shown in Figure 5.13 on page 16. NAILS CEILING FIRES TOP MIN. 1 in. (25mm) CLEARANCE MIN. 1 in. (25mm) CLEARANCE MIN. 1 in. (25mm) CLEARANCE MIN. 1 in. (25mm) CLEARANCE Figure 5.16 WARNING Fire Risk. Explosion
Resumo do conteúdo contido na página número 18
2. Cathedral Ceiling Step 1. Follow installation Steps 1 and 2 under vertical installation section, page 15. Step 2. Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box. Cut the hole 1/8 in. (3mm) larger than the support box outline. Step 3. Lower the support box through the hole in the roof until the bottom of the support box protrudes at least 2 in. (51mm) below the ceiling (Figure 5.17). Align the support box both vertically and horizontal
Resumo do conteúdo contido na página número 19
3. Class A Metal Chimney Step 4. Pass the flex pipe down through the center of the chimney system, and center the top adapter on the top of the chimney pipe. Drill four 1/8 in. (3mm) diameter holes through the TERMINATION CAP top adapter, and into the chimney top. Ensure that you are TOP drilling into the metal on the chimney. Twist lock the high ADAPTOR wind termination cap onto the top adapter (Figures 5.22 FLASHING and 5.23). EXISTING METAL CHIMNEY SYSTEM 4 in. (102mm) FLEX P
Resumo do conteúdo contido na página número 20
4. Existing Masonry Chimney Type A & B Co-Axial to Co-Linear CHIMNEY LINER CHIMNEY LINER TERMINATION TERMINATION CAP CAP 25 ft. (8m) OF 3 in. (76mm) FLEX LINER EXHAUST SECTION 3 in. (76mm) THIS SECTION OF CO-AXIAL TO FLEX LINER THE CHIMNEY MUST CO-LINEAR BE SEALED CO-AXIAL TO CONNECTOR CO-LINEAR CONNECTOR THE CHIMNEY MUST BE PIPE LENGTH SEALED FROM THE 4 ft. (1m) PIPE LENGTH OPTIONAL SECTION TO TERMINATION OPTIONAL USING A SMOKE SHELF OR A DAMPER. THE SEAL SHOULD BE 6 in. (15