Resumo do conteúdo contido na página número 16
VENTING INSTALLATION INSTRUCTIONS Installation for Vertical Terminations Cont.) 16 Parts Lists for Venting Kits Components VENTING INSTALLATION INSTRUCTIONS Continued PARTS LISTS FOR VENTING KITS AND COMPONENTS DESA (5/8”) Pipe & Vent Kits Number Description P58-6 6” Section Double Wall Pipe Galvanized Install Note: P58-12 12” Section Double Wall Pipe, Galvanized restrictor ring P58-24 24” Section Double Wall Pipe, Galvanized into inner pipe P58-36 36” Section Double Wall Pipe, Ga
Resumo do conteúdo contido na página número 17
ELECTRICAL SUPPLY CONNECTION OPTIONAL BLOWER INSTALLATION 17 Models BK and BKT ELECTRICAL SUPPLY CONNECTION J-BOX COVER w/ J-BOX COVER STRAIN RELIEF CAUTION: Disconnect the electrical power to the J-BOX supply circuit before attempting to connect or service COVER w/ this appliance. STRAIN RELIEF ROMEX WARNING: This appliance, when installed must be CABLE SCREW - TAB RETAINER electrically grounded in accordance with local code or in the absence of local code, with the current National J-BOX
Resumo do conteúdo contido na página número 18
OPTIONAL BLOWER INSTALLATION (Cont.) Models BK and BKT 18 OPTIONAL BLOWER INSTALLATION Continued Duplex 4. Be certain that all wire terminals are securely attached to ter- Outlet minals on blower motor and that the screw retaining the green ground wire is tight. Blower Plug-in 5. Mount speed control box by placing the plastic control shaft Speed Control through the opening in switch bracket (see Figure 34) or Control the igniton module bracket (see Figure 35). Shaft 6. While supporting sp
Resumo do conteúdo contido na página número 19
24 VAC SYNETEK CONTROLS INC MODEL IS1070B O OPTIONAL BLOWER INSTALLATION (Cont.) Models BK and BKT) 19 WiIRING DIAGRAMS Blower Wiring Diagram Millivolt Ignition Wiring Diagram Electronic Ignition Wiring Diagram OPTIONAL BLOWER INSTALLATION Continued 4. Be certain that all wire terminals are securely attached to ter- WIRING DIAGRAMS minals on blower motor and thermal switch, and that the screw for the thermodisc bracket and green ground wire is tight. CAUTION: label all wires prior to disconn
Resumo do conteúdo contido na página número 20
INSTALLING OPTIONAL CONTROLS Installing Optional Wall Mount Switch - GWMS2 20 Installing Optional Wireless Hand-Held Remote Control - GHRC and GHRCT Series INSTALLING OPTIONAL CONTROLS Installing 9-Volt Alkaline Battery in Hand-Held Remote INSTALLING OPTIONAL WALL MOUNT Control Unit SWITCH - GWMS2 1. Remove battery cover on back of remote control unit. 2. Attach terminal wires to a 9-volt alkaline battery (not included). 1. Connect one terminal of 15 ft. wire from the wall switch to the TPTH
Resumo do conteúdo contido na página número 1
DIRECT-VENT FIREPLACE
OWNER’S OPERATION AND
INSTALLATION MANUAL
DEDICATED REAR AND TOP VENT FIREPLACES
MODELS: (V) CD36R(N,P) (E) MODELS: (V) CD36T(N,P) (E)
WARNING: If the information in this manual is not fol-
WARNING: Improper installation
lowed exactly, a fire or explosion may result causing
adjustment, alteration, service,
property damage, personal injury, or loss of life.
or maintenance can cause injury
or property damage. Refer to this
FOR YOUR SAFETY
manual for correct installation a
Resumo do conteúdo contido na página número 2
TABLE OF CONTENTS SAFETY INFORMATION 2 TABLE OF CONTENTS GAS SUPPLY AND PIPING .................................................. 21 SAFETY INFORMATION .......................................................... 2 HEARTH ACCESS AND ASSEMBLY ................................... 24 PRODUCT IDENTIFICATION ................................................... 3 OPERATING FIREPLACE ...................................................... 25 LOCAL CODES ......................................................
Resumo do conteúdo contido na página número 3
SAFETY INFORMATION PRODUCT IDENTIFICATION 3 LOCAL CODES SAFETY INFORMATION PRODUCT IDENTIFICATION Continued 5. This fireplace reaches high temperatures, Keep children and adults away from hot surfaces to avoid burns or clothing igni- tion. Fireplace will remain hot for a time after shutdown. Al- low surfaces to cool before touching. Rear Vent Flue Collar 6. Carefully supervise young children when they are in the room with fireplace. 7. Do not modify this fireplace under any circumstances. Any
Resumo do conteúdo contido na página número 4
PRODUCT FEATURES PRE-INSTALLATION PREPARATION 4 4 Location and Space Requirements PRODUCT FEATURES These are a few facts that can help you understand and enjoy your • Your fireplace is designed to be used in zero clearance installa- direct-vent fireplace: tions. Wall or framing material can be placed directly against any exterior surface on the back, sides, or top of your fireplace, • The CD36R dedicated rear vent is best suited for flush or corner except where stand-off spacers are integrally att
Resumo do conteúdo contido na página número 5
PRE-INSTALLATION PREPARATION Clearances 5 5 Framing and Finishing PRE-INSTALATION PREPARATION FIBERBOARD Continued COLLAR PROTECTOR PACKAGING AND REMOVAL The (V)CD36R/T direct vent gas fireplace heater is packaged with: - one box containg a 4-log set located on the burner in the firebox. - one bag containing the owner’s manual with installation instructions, operator’s guide, and warranty information. - one bag of glowing ember material. - one bag of vermiculite hearth treatments. Remove the shri
Resumo do conteúdo contido na página número 6
UNIT DIMENSIONS 6 REAR / TOP VENT COMMON CD36R, CD36T, VCD36R and VCD36T MANTEL CLEARANCES 1 2 Figure 8 shows projected mantel depths at various heights above the top of the louver opening. Figure 7 shows the minimum allow- 3 Stud Wall A able distances from various mantel components in relation to the 2x Vertical 4 Header both sides of the fireplace opening. @ 1” Min. B 5 Clearance C 6 WARNING: When finishing appliance, do not overlap D 5/8 Flue Pipe E 7 combustible materials onto the black front
Resumo do conteúdo contido na página número 7
V G G V A E D V B L LOCATION OF TERMINATION CAP 7 LOCATION OF TERMINATION CAP N N H C I B Fixed V V Fixed Closed Openable Closed Openable B F V G V J X B B M A V K X G V TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA X (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony I = clearance to service regulator vent outlet [*72 inches (182.9cm) [*12 inches (30.5mc) minimum] minimum] B = clearance to window or door that may be opened J = clearance to non-mech
Resumo do conteúdo contido na página número 8
VENTING INSTALLATION INSTRUCTIONS Installation Planning 8 VENTING INSTALLATION INSTRUCTIONS NOTICE: Read these instructions completely be- NOTICE: Failure to follow these instructions will void fore attempting installation. the warranty. These models are tested and approved for use with DESA (direct- INSTALLATION PRECAUTIONS vent) pipe components and terminations. The venting system must terminate on the outside of the structure and • Wear gloves and safety glasses for protection can not be atta
Resumo do conteúdo contido na página número 9
VENTING INSTALLATION INSTRUCTIONS Installation Planning (Cont.) 9 VENTING INSTALLATION INSTRUCTIONS Continued INSTALLATION PLANNING There are two basic types of direct-vent installations: Female • Horizontal Termination Locking Lugs • Vertical Termination Horizontal Termination Installation IMPORTANT: Horizontal square terminations require only inner portion of wall firestop. Horizontal installation using round termina- tion require exterior portion of wall firestop (see Figure 18, page 11). Mal
Resumo do conteúdo contido na página número 10
VENTING INSTALLATION INSTRUCTIONS Installation Planning (Cont.) 10 INNER WALL VENTING INSTALLATION FIRESTOP INSTRUCTIONS Continued 6. Noncombustible Exterior Wall: Position the horizontal vent VINYL SIDING cap in the center of the 8 ½” round hole and attach to the exte- STANDOFF rior wall with four wood screws provided. Before attaching VENT the vent cap to exterior wall, run a bead of non-hardening mastic CAP (pliable sealant) around the outside edges to make a seal be- tween it and the ou
Resumo do conteúdo contido na página número 11
VENTING INSTALLATION INSTRUCTIONS Installation Planning (Cont.) 11 Exterior Portion of Wall Wall 90° Elbow VENTING INSTALLATION Firestop (Round Firestop Termination Only) INSTRUCTIONS Continued Horizontal Termination Configuration Figures 19 through 25 show different configurations and alterna- tives for venting with horizontal terminations. Each figure includes Horizontal Round a chart with critical minimum and maximum dimensions which Termination MUST be met. IMPORTANT: Remember that a horizontal
Resumo do conteúdo contido na página número 12
VENTING INSTALLATION INSTRUCTIONS Installation Planning (Cont.) 12 VENTING INSTALLATION INSTRUCTIONS Continued GROUND FLOOR INSTALLATION TOP VENT Required Vertical (V) Allowable Vertical (V) Vertical Pipe Horizontal (H) Recommended Applications for Top Vent Model (V)CD36T: 45 ½” None 26” Max. • Installation using cabinet surrounds 57 ¼” Min. 1 ft. 30” Max. • Through the wall using round or square termination 69 ¼” Min. 2 ft. 74” Max. (up to a maximum of 24” of horizontal pipe) 81 ½” Min.
Resumo do conteúdo contido na página número 13
VENTING INSTALLATION INSTRUCTIONS Installation Planning (Cont.) 13 HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows. Venting with Two 90° Elbows 90° Elbow Horizontal (H ) + 1 Vertical (V) Horizontal (H ) 2 8' min. 9' max. 9' min. 11' max. 10' min. 13' max. 12' min. 17' max. 14' min. 20' max. Figure 24 - Horizontal Termination Configuration for Venting using Two 90° Elbows (Mode
Resumo do conteúdo contido na página número 14
VENTING INSTALLATION INSTRUCTIONS Installation for Vertical Terminations 14 VENTING INSTALLATION INSTRUCTIONS 2. Assemble the desired lengths of pipe and elbows necessary to Continued reach from the fireplace flue up through the firestop. Be sure all pipe and elbow connections are fully twist-locked (see Fig- Note: Vertical restrictor must be installed in all vertical installations. ure 11, page 9). 1. Determine the route your vertical venting will take. If ceiling 3. Cut a hole in the roof usin
Resumo do conteúdo contido na página número 15
VENTING INSTALLATION INSTRUCTIONS Installation for Vertical Termination (Cont.) 15 VENTING INSTALLATION INSTRUCTIONS Install Note: Continued restrictor ring into inner pipe Vertical Termination Configurations section prior to attaching vent Figures 28 through 31 show four different configurations for verti- termination cap. cal termination. Venting with Two 90° Elbows Vertical (V) Horizontal H Venting with Three 90° Elbows 8' min. 6' max. 90° Elbow Vertical (V) Horizontal (H ) + 1 9' mi