Resumo do conteúdo contido na página número 1
12V Cordless Auto-Hammer
68364 12V Cordless Auto-Hammer
Read this material before using this product.
Failure to do so can result in serious injury.
Save this manual.
When unpacking, make sure that the product is intact and undamaged. If any parts are missing or broken,
please call 1-800-444-3353 as soon as possible.
Visit our website at: http://www.harborfreight.com
© ®
Copyright 2010 by Harbor Freight Tools . All rights reserved. No portion of this manual or any artwork contained herein
Resumo do conteúdo contido na página número 2
Specifications Charger Input 120 V~ / 60 Hz DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. Charging Time 3-5 Hours Battery Type 12V, Ni-Cd, 800 mAh Nail Size 2-1/2” Max. Length WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and CAUTION, used with the safety alert
Resumo do conteúdo contido na página número 3
3. Personal safety d. Store idle power tools out of the reach of children and do not allow persons unfamiliar a. Stay alert, watch what you are doing and use with the power tool or these instructions common sense when operating a power tool. Do to operate the power tool. Power tools are not use a power tool while you are tired or under dangerous in the hands of untrained users. the influence of drugs, alcohol or medication. A moment of inattention while operating power e. Maintain pow
Resumo do conteúdo contido na página número 4
13. People with pacemakers should consult their Auto Hammer Safety Warnings physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker 1. Wear hearing protection during use; interference or pacemaker failure. In addition, people Auto Hammer is loud during operation. with pacemakers should: • Avoid operating alone. 2. Do not use Auto Hammer with • Do not use with power switch locked on. nails longer than 2-1/
Resumo do conteúdo contido na página número 5
as tingling, numbness, and white or blue fingers), 1. Tools marked “Double Insulated” do not require seek medical advice as soon as possible. grounding. They have a special double insulation system which satisfies OSHA requirements and 2. Do not smoke during use. Nicotine reduces complies with the applicable standards of Underwriters the blood supply to the hands and fingers, Laboratories, Inc., the Canadian Standard increasing the risk of vibration-related injury. Association, and the
Resumo do conteúdo contido na página número 6
Functions Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: Release the Trigger and disconnect Battery Pack before assembling or making any adjustments to the tool. Note: For additional information regarding the parts listed in the following pages, refer to Parts List and Assembly Diagram on page 11. Magnetic
Resumo do conteúdo contido na página número 7
hours to fully charge. CAUTION! Recharging the Operating Instructions Battery Pack for more than 5 hours can damage the battery cells. Keep track of charging time. Read the ENTIRE IMPORTANT SAFETY 5. While charging, the Battery Pack and Charger, INFORMATION section at the beginning and Adapter may become warm to the touch. This of this manual including all text is normal, and does not indicate a problem. under subheadings therein before set up or use of this product. 6. Unplug the Char
Resumo do conteúdo contido na página número 8
4. Once the nail is loaded, secure the workpiece with clamps. Maintenance and Servicing CAUTION: Use a scrap piece of wood Procedures not specifically explained to test the potential of marring your in this manual must be performed workpiece when using finish nails. only by a qualified technician. 5. Use your free hand to steady the point of the nail at the desired location on the workpiece. TO PREVENT SERIOUS INJURY FROM WARNING! Wear ANSI-approved safety goggles, ACCIDENTAL OPERA
Resumo do conteúdo contido na página número 9
Troubleshooting Problem Possible Causes Likely Solutions Tool will not start. 1. No power at outlet during 1. Check power at outlet. If outlet is unpowered, charging. turn off tool and check circuit breaker. If breaker is tripped, make sure circuit is right capacity for tool and circuit has no other loads. 2. Internal damage or 2. Have technician service tool. wear. (Carbon brushes or switch, for example.) Excessive noise Internal damage or wear. (Carbon Have technician service tool. or
Resumo do conteúdo contido na página número 10
Parts List and Assembly Diagram PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THA
Resumo do conteúdo contido na página número 11
Parts List and Assembly Diagram 1 2 11 10 7 6 9 5 4 3 8 12 13 14 15 16 17 44 43 42 41 40 39 38 18 37 19 36 35 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 SKU 68364 For technical questions, please call 1-800-444-3353. Page 11
Resumo do conteúdo contido na página número 12
Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear