Resumo do conteúdo contido na página número 1
CONTENTS
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MOUNTING RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PREPARATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FAN INSTALLATION . . . . . . . . . . . .
Resumo do conteúdo contido na página número 2
MOUNTING RECOMMENDATIONS Before mounting your Casablanca fan, read the following helpful recommendations. The location of the fan, air circulation, and fan size are all important factors to consider before installation. Location Ceiling fans have practical uses in almost every room in your home. We suggest you follow these mount- ing recommendations as you decide where to install your Casablanca fan. � For safety reasons, the fan blades must be a minimum of 7 ′ above the fl oor. � Do not locat
Resumo do conteúdo contido na página número 3
™ VERRAZANO PREPARATION INSTRUCTIONS Unpacking: Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them against the parts listed here. Before discarding packaging material, be certain that all parts have been removed. GETTING STARTED Carton Contents Be sure to use only genuine Casablanca blades. The blade The fan carton contains the fan body, warranty card, owner’s shrink wrap holds 4 blades of matched weight. If more than manual, and all
Resumo do conteúdo contido na página número 4
CEILING HARDWARE ADDITIONAL HARDWARE 1 2 /4” x 8-32 ROUNDED HEAD SCREW (2) CROSSBAR MOUNT- WIRE NUT (4) 1” x 8-32 ROUNDED ING BRACKET FLAT WASHER (2) HEAD SCREW (2) SUPPORT INSTALLATION PARTS LARGE LAG SCREW FLAT WASHER ¼” #7 X 5” (1) ¼” (1) CROSSBAR MOUNTING BRACKET INSTALLATION JOIST Note: After removing the old fi xture, check the outlet box to ensure that it is supported by a joist or beam across its upper surface. If not, a 2” x 4” stud must be installed. Step 1. Remove the knockout pl
Resumo do conteúdo contido na página número 5
™ VERRAZANO LAG SCREW INSTALLATION Step 3. With the large washer attached, pass the lag screw through the center hole of the crosbar mounting bracket and screw into guide hole. Tighten until outlet box is fi rmly mounted to beam. This box must be secured fi rmly to the ceiling. We recommend that the ceiling fi xture outlet box be of suffi cient capacity enabling it to support the weight of fan and light fi xture under any conditions. LAG SCREW LARGE WASHER CANOPY HARDWARE CANOPY SCREW (4) CANO
Resumo do conteúdo contido na página número 6
HANGING THE FAN Step 5. To hang the fan body in the canopy, hold the fan CANOPY body fi rmly and insert the nylon ball into the canopy open- ing. Rotate fan body until slot on nylon ball fi ts into pin opposite canopy opening. NOTE: The fan weight is 37.5 pounds. BALL SLOT PIN W-1811 WIRING BLACK 120V AC WHITE GREEN BLACK & YELLOW YELLOW RED GROUND 2 WHITE RED AND BLUE D-1 3 GREEN WIRE NUT BLACK Step 6a. Connect the fan wires to the outlet box wiring by placing the bare ends of the wires toge
Resumo do conteúdo contido na página número 7
™ VERRAZANO INSTALLATION OF WALL CONTROL Step 6b. The W-18 / W-28 is designed to replace a standard 7. Install the W-18 / W-28 in the wall box with the two long wall switch and will fi t wall boxes (metal or plastic) with screws provided. a depth of 2” or greater. CAUTION: Be sure no wires are pinched! CAUTION: Ensure power is turned OFF at the breaker or fuse panel before start- ing installation. 8. Install the wall plate with the two color matched screws. 9. Turn on power to test the control
Resumo do conteúdo contido na página número 8
BLADE HARDWARE BLADE TIP SCREW BLADE SCREW (2 PER BLADE) (3 PER BLADE) BLADE ROD BLADE TIP BLADE INSTALL BLADE RODS Step 10. Remove the shipping cover from each of the blade rod holders on the fan body. BLADE ROD Using the provided Allen wrench, unscrew Note: Do NOT HOLDER SCREW the blade rod holder screw a few turns install the rub- (PRE-INSTALLED) to assure proper installation of the blade ber-tipped end SHIPPING rod. Insert the metal end of the blade rod into the blade COVER (NOT th
Resumo do conteúdo contido na página número 9
™ VERRAZANO LIGHT KIT PARTS LIGHT KIT SCREWS LIGHT KIT BULB PLATE LIGHT KIT BASE REMOVE SWITCH HOUSING SCREWS Step 13. Remove the three screws from the switch housing and set aside for use in Step 14. SWITCH HOUSING TABS SWITCH HOUSING SCREWS INSTALL LIGHT KIT BASE Step 14. Route the motor wires through the center of the light kit base. Align the light kit base onto the switch housing using the tabs of the switch housing. Using the three switch housing screws removed in Step 13, attach th
Resumo do conteúdo contido na página número 10
INSTALL LIGHT KIT BASE Step 15. Attach the WHITE wire plug from the bulb plate to the WHITE wire plug of the fan. Then at- tach the BLACK wire plug from the bulb plate to the BLACK wire plug of the fan. The plugs have alignment tabs, assure these are aligned —do not force the connection. Using the provided light kit screws, attach the light kit bulb plate to the light kit base, securing by hand only. Assure that no wires are pinched. ALIGNMENT LIGHT KIT TAB BULB PLATE ALIGNMENT LIGHT K
Resumo do conteúdo contido na página número 11
W-1811 CEILING FAN/LIGHT CONTROL W-1811 OPERATION 1. Raise the Fan slider to increase fan speed, lower it to decrease. 2. For the fan, four positions are available: OFF, LOW, MEDIUM, and HIGH. The bottom position is OFF. 3. The Light slider is a dimmer, the bottom is OFF; raise to increase intensity of the light. REVERSING FAN DIRECTION The direction of blade rotation is controlled by the reverse slide switch on the top of the motor body of the fan. Direction your fan should go in summer a
Resumo do conteúdo contido na página número 12
TROUBLESHOOTING Before requesting service: Please consult this troubleshooting guide before contacting your dealer for assistance. FAN WILL NOT START Check main circuit fuses, circuit breakers, or wall switch position. Check all wire connections, making sure the power is turned off during this inspection. Check that reverse switch is not set in center of throw. FAN WOBBLES OR SHAKES Be sure canopy pin is properly set into the slot on the ball. EXCESSIVELY Check the screws holding the blade ho
Resumo do conteúdo contido na página número 13
™ VERRAZANO AUTHORIZED SERVICE CENTERS STATE/CITY ZIP SERVICE CENTER NAME PHONE TYPE TYPES OF SERVICE OFFERED: FFS = FULL FAN SERVICE IHO = IN-HOME ONLY ISO = IN-SHOP ONLY COLORADO ISW = IN-SHOP ONLY/ONLY WHAT THEY SELL OWS = ONLY WHAT THEY SELL BOULDER 80306 ENERGETICTECH 303-684-7543 FFS COLORADO SPRINGS 80903 HOME LIGHTING 719-471-3520 WTS STATE/CITY ZIP SERVICE CENTER NAME PHONE TYPE DENVER 80229 M.D ELECTRIC 303-288-7988 FFS FORT COLLINS 80525 LIGHT CENTER 970-226-3430 WTS ALA
Resumo do conteúdo contido na página número 14
AUTHORIZED SERVICE CENTERS STATE/CITY ZIP SERVICE CENTER NAME PHONE TYPE STATE/CITY ZIP SERVICE CENTER NAME PHONE TYPE IOWA NEBRASKA CARROLL 51401 J & L ELECTRIC INC. 712-792-2444 ISO GRAND ISLAND 68803 QUALITY SEW & VAC 308-382-7310 ISO CEDAR RAPIDS 52404 ACME ELECTRIC COMPANY 319-365-8677 FFS LINCOLN 68510 LINCOLN LIGHTING CENTER 402-476-1297 FFS CORALVILLE 52241 RALSTON CREEK 319-351-2189 S2W NORFOLK 68701 THE POWER STATION 402-371-6671 FFS DAVENPORT 52803 SHAW ELECTRIC 563-323-3
Resumo do conteúdo contido na página número 15
™ VERRAZANO AUTHORIZED SERVICE CENTERS STATE/CITY ZIP SERVICE CENTER NAME PHONE TYPE STATE/CITY ZIP SERVICE CENTER NAME PHONE TYPE OHIO CARROLLTON 75006 ADFANTAGE CEILING FANS 972-446-9393 FFS CANTON 44706 APPLIANCE PARTS CO. 330-453-8077 ISO CORPUS CHRISTI 78404 BRAND APPLIANCE & MICROWAVE 361-854-1851 ISO CLEVELAND 44109 WESTSIDE LIGHTING CTR. 216-459-1970 FFS DALLAS 75206 LIGHTS FANTASTIC 214-369-1101 FFS COLUMBUS 43231 THE LAMP LIGHTER 614-891-7940 FFS DAMON 77430 GULF COAST FAN SVC